Quick Start Guide
– 3 –
1.
Connect the ground wire / protective earth.
2.
Connect the -36 – -72 VDC wire.
3.
Connect the DC return wire.
Make Network Connections
QSFP28/SFP28/SFP+ Ports
Install transceivers and then connect fiber optic cabling to the transceiver
ports. Alternatively, connect AOC/DAC cables directly to the QSFP28/
SFP28/SFP+ slots.
The following transceivers are supported in the QSFP28 ports:
■
100GBASE-SR4
■
100GBASE-LR4
■
100GBASE-ER4
The following transceivers are supported in the SFP28 ports:
■
25GBASE-SR
■
25GBASE-LR
The following transceivers are supported in the SFP+ ports:
■
10GBASE-SR
■
10GBASE-LR
■
10GBASE-ER
■
10GBASE-ZR
RJ-45 Ports
For the 1G RJ-45 ports, connect 100-ohm Category 5, 5e or better
twisted-pair cable.
Connect Timing Port
RJ-45 PPS/ToD
Use a Cat. 5e or better twisted-pair cable to connect the 1-pulse-per-
second (1PPS) and Time of Day (ToD) to other synchronized devices.
Make Management Connections
MGMT RJ-45 Port
Connect Category 5, 5e or better twisted-pair cable.
RJ-45 Console Port
Use the included RJ-45-to-DB-9 null-modem console cable to connect to
a PC running terminal emulator software. Use a USB-to-male DB-9
adapter cable (not included) for connections to PCs that do not have a
DB-9 serial port.
Configure the serial connection: 115200 bps, 8 characters, no parity,
one stop bit, 8 data bits, and no flow control.
Console cable pinouts and wiring:
Caution:
Before connecting power supply cables to the router,
ensure that power to the feed lines is turned off at the supply
circuit breaker or disconnected from the power bus.
Attention:
Avant de connecter les câbles d’alimentation au
routeur, assurez-vous que l’alimentation des lignes
d’alimentation est coupée au niveau du disjoncteur
d’alimentation ou déconnectée du bus d’alimentation.
Caution:
Use a UL/IEC/EN 60950-1 and/or 62368-1
certified power supply to connect to a DC converter, and a #14
AWG/1.5 mm
2
(for 36 VDC to 72 VDC PSU) wire to connect to
a DC PSU.
Attention:
Utilisez une alimentation certifiée UL/IEC/EN
60950-1 et/ou 62368-1 pour le connecter à un convertisseur
CC et un câble AWG #14/1.5 mm
2
(pour 36 VDC à 72 VDC)
pour vous connecter à une alimentation CC.
Caution:
All DC power connections should be performed by
a qualified professional.
Attention:
Toutes les connexions d’alimentation CC doivent
être effectuées par un professionnel qualifié.
Note:
It is suggested to use the following for DC power:
One UL 1015 AWG#10-14 stranded wire, 2m maximum
(36VDC-72VDC: Input+)
One UL 1015 AWG#10-14 stranded wire, 2m maximum (VDC
return: Input-)
One UL 1015 AWG#10-14 stranded wire, 2m maximum,
(green/yellow) green with yellow stripe (PE)
Note:
The DC terminal screws should be tightened to a
torque of 7 in-lbs maximum.
1
3
2
4
Router’s RJ-45 Console
Null Modem
PC’s 9-Pin DTE Port
6 RXD (receive data)
<----------------
3 TXD (transmit data)
3 TXD (transmit data)
---------------->
2 RXD (receive data)
4,5 SGND (signal ground) ------------------
5 SGND (signal ground)
5