background image

MicroSCADA Pro SYS 600C 1.92

Product Guide

Summary of Contents for MicroSCADA Pro SYS 600C

Page 1: ...MicroSCADA Pro SYS 600C 1 92 Product Guide ...

Page 2: ......

Page 3: ...Time synchronization 16 3 6 Redundancy 16 3 7 Mirroring 16 3 8 OPC connectivity 17 3 9 Key benefits 17 4 Application areas 19 4 1 Overview 19 4 2 SYS 600C as Communication Gateway 20 4 3 SYS 600C as Control System HSI 21 4 4 SYS 600C as Communication Server 23 5 Product structure 25 5 1 Ordering delivery and life cycle policy 25 5 2 Software options 26 5 2 1 Communication protocols 26 5 2 2 HSI fe...

Page 4: ...7 Capacity and performance 36 7 1 SYS 600C capacity 36 7 2 Data logging capacity 36 7 3 Process communication capacity 37 4 1MRS756804 MicroSCADA Pro SYS 600C 1 92 Product Guide ...

Page 5: ...and parts thereof must not be reproduced or copied without written per mission from ABB Oy and the contents thereof must not be imparted to a third party nor used for any unauthorized purpose The software or hardware described in this document is furnished under a license and may be used copied or disclosed only in accordance with the terms of such license Copyright 2009 ABB All rights reserved Tr...

Page 6: ...der to relevant facts and conditions Abbreviations 2 3 Description Abbreviation Compact flash CF Central Processing Unit CPU Distributed Common Object Model DCOM Distributed Control System DCS Dynamic Host Configuration Protocol DHCP Dual in line package DIP Electromagnetic Interference EMI Electromagnetic Shielding EMS Human System Interface HSI Integrated Drive Electronics IDE Intelligent Electr...

Page 7: ...ated documents 2 4 Document ID Name of the document 1MRS756805 SYS 600C User s Guide 1MRS756115 SYS 600 9 2 Installation and Administration Manual 1MRS756112 SYS 600 9 2 System Configuration Document revisions 2 5 History Date Software revision number Version Document created 27 5 2009 1 92 A Minor updates 23 6 2009 1 92 B Power supply correc tions 30 9 2009 1 92 C 7 SYS 600C 1 92 MicroSCADA Pro 1...

Page 8: ...archived presented on the HSI or forwarded to other systems See 3 8 OPC connectivity for more connectivity options Remote communication The remote communication is used to connect SYS 600C to upper level systems such as Network Control Systems The most common protocols such as IEC 60870 5 101 104 DNP 3 0 and RP570 are supported See 5 2 1 Communication protocols for the full list of supported proto...

Page 9: ...ities are defined by the access rights given to the user in question Also the layout and functions of the workplaces can be fully customized for each user The distributed workplace concept is based on available remote access techniques typ ically Microsoft Terminal Server or Citrix Access Essentials Any PC or other web enabled device can be used as a workstation without installing any additional s...

Page 10: ...ws information about the base system applications redundancy communication lines IEDs and so on The system can also receive status information from any device or external software reporting to the Windows event log for example disks power supplies and computer boards Communication equipment and peripheral devices that support SNMP can also be supervised by using an SNMP OPC gateway Event Display 3...

Page 11: ...rm Display 3 2 4 The alarm display shows the alarms of the system in a list as shown in Figure 3 2 4 1 It supports easy sorting and filtering of the events to make the alarm analysis as easy as possible It can also be freely configured to display the information the layout and col oring of the alarms It is also possible to have predefined filters that can easily be accessed from toolbars and menus...

Page 12: ...ay lists all active blockings in the system The display can also be used to activate new blockings The following aspects of a signal can be blocked updating control event logging alarm generation event printout and post processing 12 1MRS756804 MicroSCADA Pro SYS 600C 1 92 Product Guide ...

Page 13: ...ata in a numerical or graphical form It is used for following up and analyzing data in time frames from minutes to one month The data is logged cyclically in intervals of 30 seconds 1 2 5 or 10 minutes The trends display can log and show any type of data available in the process database 13 SYS 600C 1 92 MicroSCADA Pro 1MRS756804 Product Guide ...

Page 14: ...riods than the Trends Display and it is dedicated for energy current voltage temperature and frequency reports The available time ranges for the reports Hourly report time resolution 3 minutes Daily report time resolution 15 minutes Daily report time resolution 30 minutes Daily report time resolution 60 minutes Weekly report time resolution one day Monthly report time resolution one day Yearly rep...

Page 15: ...rocess Localization 3 4 It is possible to translate the user interface to any language that fits into the boundaries of the graphical user interface that is size position and direction of texts and icons The system also supports several languages simultaneously enabling operators to work with the system in their native language The language is part of the user profile and is selected automatically...

Page 16: ...r is in the same state as the active one If the active computer breaks down the stand by computer takes over the process communication and continues to manage the process In this way the process can be operated and supervised even if one of the computers fails Communication redundancy Redundant communication lines mean that two or several connections between the master and the slave form a logical...

Page 17: ...rite data commands parameters and so on to the server SYS 600C provides OPC connectivity both in forms of clients and servers that is SYS 600C can receive data from a device or system that provides its data through an OPC server SYS 600C can also provide its data to another system that acts as a client Key benefits 3 9 SYS 600C offers the following highlights and key benefits Solid state hardware ...

Page 18: ...ation Easy to upgrade with latest software versions that enable use of new and innovative functionality Powerful HSI Powerful data collection to be used in single line diagrams process displays trends reports control alarms and events Process displays with support for traces zoom pan de clutter Trends with zoom pan multiple smart axes ruler cut and paste 18 1MRS756804 MicroSCADA Pro SYS 600C 1 92 ...

Page 19: ...ator actions The consistent use of known technologies and intuitive user interfaces ensures an easy entry level for new SYS 600C users Fields of application SYS 600C is designed to be used in a wide range of applications in both Electrical Util ities and Industries When using SYS 600C in substations the main application is as a Communication Gateway to the upper level system or it is used as a pow...

Page 20: ...cation Gateway function can be configured as a single gateway as shown in Figure 4 2 1 C_20090101 bmp Figure 4 2 1 SYS 600C as Communication Gateway Utilizing the OPC interface in SYS 600C enables an easy and efficient integration of IED signals and information into a DCS system as shown in Figure 4 2 2 This configuration is typically applied in Process Industries with distributed Intelligent Elec...

Page 21: ...ion lines to Remote Control Center SYS 600C as Control System HSI 4 3 SYS 600C HSI provides numerous options for monitoring and controlling a connected process SYS 600C handles both the HSI functionality and the Communication Gateway functionality In this way SYS 600C can act both as a Communication Gateway enabling a remote connection to control centers as well as the local control system and HSI...

Page 22: ...ntrol System HSI and Communication Gateway For increased availability SYS 600C can be configured as a redundant Control System HSI and integrated Communication Gateway with redundant communication lines to Remote Control Center as shown in Figure 4 3 3 C_20090107 bmp Figure 4 3 3 SYS 600C as redundant Control System HMI and integrated Communication Gateway SYS 600C can also be utilized as an HSI f...

Page 23: ... 600C with its large number of serial communication ports and LAN ports in com bination with the solid state technology offers an excellent Communication Server solution The Communication Server solution is offered and available as a part of larger SYS 600 or SYS 600C configurations as shown in Figure 4 4 1 and Figure 4 4 2 C_20090109 bmp Figure 4 4 1 SYS 600C as Communication Server in a Remote C...

Page 24: ...e SYS 600C Communication Server solution the processing load in the main system servers SYS 600 or SYS 600C is reduced The Communication Servers are connected to the process devices and provide the main system servers SYS 600 or SYS 600C with process information 24 1MRS756804 MicroSCADA Pro SYS 600C 1 92 Product Guide ...

Page 25: ...st price of the new hardware 2 The hardware is upgraded to a new version and the SYS 600 software is also upgraded to a new version The total price is the list price of the new hardware the upgrade price of the SYS 600 software If the hardware is upgraded the Hardware Key inside the old SYS 600C computer must be removed and reused for some other SYS 600 license SYS 600C has three PCI slots for add...

Page 26: ... the Hardware Key that is installed inside the computer Product identification The SYS 600C product is identified by the computer version and the SYS 600 software version Example SYS 600C 1 92 Hardware version 1 SYS 600 software version 9 2 Software options 5 2 Communication protocols 5 2 1 The following tables list the communication protocols of SYS 600C Table 5 2 1 1 Master protocols Master prot...

Page 27: ...r of work places needed is defined in the following way A workplace means a computer PC Laptop PDA ThinClient which can have one or several physical screens from where ONE person at a time can operate Several Application Windows can be used in one workplace Nr of Pro workplaces Yes No Select this option if you want to use Process Displays in the workplaces Process Displays means displays with zoom...

Page 28: ...s Yes No Select this option if you want to integrate PCM 600 Tools in the Process Displays PCM 600 interface Yes No Select this option if you want to integrate LIB 510 542 IED Tools in the Workplace If you use only the IED tools in the Workplace no other LIB license in needed LIB 510 542 IED Tools Yes No Select this option if you want to integrate LIB 520 IED Tools in the Workplace If you use only...

Page 29: ...option can be left out in pure monitoring systems where no output process objects are needed You also need this option in gateway systems if commands are propagated through the gateway Control Yes No This option allows 10 000 000 entries of history data to be archived Data objects This option is needed for example for the Measurement Reports This option is not needed for the standard Trends Withou...

Page 30: ... system server is the Image Database mirroring IMAGE Yes No This option enables the OPC DA server function The option should be selected if the sys tem is to be connected to an external OPC DA Client for example 800xA HIS 600 OPC DA Server 0 3 This option is primarily intended for HSB systems to which an external OPC DA client is con nected for example HIS 600 This Application OPC server is instal...

Page 31: ... server that is to be connected The DA client is tightly integ rated with the process data base and run always on the SYS 600 computer OPC DA Client 0 4 The OPC A E client is used to connect foreign devices to SYS 600 by means of the OPC A E interface You need one client for each server that is to be connected OPC A E Client Yes No The SQL Export option provides a tool and functions for browsing t...

Page 32: ...45 Ethernet ports 2 x RJ45 4 x LC Table 5 3 2 Operating systems Operating system Windows XP Professional English version Windows XP Professional Chinese version Windows Server 2003 English version Windows Server 2003 Chinese version 32 1MRS756804 MicroSCADA Pro SYS 600C 1 92 Product Guide ...

Page 33: ...Ethernet RJ45 or LC at rear panel 1 x Gigabit Ethernet at front panel RJ45 LAN ports 2 x USB at rear panel USB 2 0 1 x USB at front panel USB 2 0 1 x USB internal USB 2 0 USB AC97 2 1 Audio PS 2 Keyboard Mouse 88 132 VAC 45 160 VDC 176 264 VAC 200 370 VDC Redundant power supply is optional Power supply 438W x 130H x 312D mm excluding rack mount accessories 3U height 19 rack mountable Dimension Ope...

Page 34: ...bstation Damped Oscillatory Burst IEC 61000 4 12 1995 Level 3 15Hz 150KHz Conducted RF Immunity IEC 61000 4 16 2002 30 120ms 70 10ms 100 3ms cycle 3 Voltage Dips Interrupts IEC 61000 4 29 2000 Class A Conducted and Radiated Emissions CISPR22 2008 Class A Conducted and Radiated Emissions FCC 15 Class A Conducted and Radiated Emissions EN55022A 500VDC 1min 999Mohm 100Mohm Insulation resistance measu...

Page 35: ...C 60068 2 1 65 C Start Up for 16 hours Dry Heat Temperature IEC 60068 2 2 Test Db 6 cycles 25 C 55 C 93 95 1 cycle 24hrs Humidity Damp heat Cyclic IEC 60068 2 30 95 non condensing 40 C 2d Humidity Damp heat Steady state IEC 60068 2 3 10 200 500 200 10Hz 1g 1 5g X Y Z axes Vibration IEC 60870 2 2 1996 10g 11ms X Y X axes Shock IEC 60870 2 2 1996 10g repeat 1000 times X Y Z axes Bump Packed IEC 6006...

Page 36: ...r workplaces they consume computer capacity and thereby the process communication capacity must be reduced accord ingly For IEC 61850 the capacity is mainly affecting the number of messages and thus it is more important that this is reduced than the number of IEDs The impact on the process communication capacity of the other functions is given in percentage Example How many IEDs can be connected o...

Page 37: ...850 capacity Then the actual maximum LON capacity is 40 of the indicated maximum capacity The following tables show the maximum communication capacity for the most commonly used protocols Table 7 3 1 Maximum communication capacity Comments Value IEC 61850 800 s Nr of messages 160 Nr of IEDs 4 Nr of IEC 61850 clients LON Maximum 30 IEDs per XLON card 90 Nr of IEDs Limited by available PCI slots 3 N...

Page 38: ...unication Function Always included 0 Local process database 2 Mirroring 2 Hot Stand by redundancy 25 when total data update rate to all NCCs is 50 from the process data update rate 25 0 Gateway NCC connec tions 24 when Process display with 1 050 measurement objects in Workplace 18 when Process display with 1 050 switching device objects in Workplace 4 when Process display with 150 measurement obje...

Page 39: ...esulting in 1 600 process updates per second sent to two NCCs NCC connection with one IEC 104 LAN communication including 158 IEDs resulting in 1 900 process updates per second sent to one NCC NCC connection with two IEC 104 LAN communications including 116 IEDs res ulting in 2 800 process updates per second sent to two NCCs The following list shows some examples when IEDs are connected to SYS 600...

Page 40: ...40 ...

Page 41: ......

Page 42: ... us 1MRS756804 C 30 9 2009 Copyright 2009 ABB All rights reserved ABB Oy Substation Automation Products P O Box 699 FI 65101 VAASA FINLAND Tel 358 10 22 11 Fax 358 10 224 1094 www abb com substationautomation ...

Reviews: