background image

 

TEKTELIC

 

C

OMMUNICATIONS 

I

NC

.

 

Document type: 

User Guide 

Document number: 

T0005158_UG 

Document version: 

0.6 

Document Status: 

Approved 

Product name: 

Kona Macro Gateway 

Product codes: 

See Table 1

 

 

 

 

 

 

 

 

TEKTELIC Communications Inc. 
7657 10

th

 Street NE 

Calgary, AB, Canada  T2E 8X2 
Phone: (403) 338-6900 

 

© 2019 TEKTELIC Communications Inc., All rights reserved. 
 
All products, names and services are trademarks and registered trademarks of their respective companies. 
 

Disclaimer: 

Material contained in this document is subject to change without notice. The material herein is solely for 
information purposes and does not represent a commitment by TEKTELIC or its representatives. TEKTELIC has 
prepared the information contained in this document solely for use by its employees, agents, and customers. 
Dissemination of this information and/or concepts to other parties is prohibited without the prior written consent 
of TEKTELIC. In no event will TEKTELIC be liable for any incidental or consequential damage in connection with the 
furnishing, performance or use of this material. 
 
TEKTELIC reserves the right to revise this publication in accordance with formal change control procedures defined 
by TEKTELIC. 

 

Summary of Contents for Kona Macro Gateway

Page 1: ...is subject to change without notice The material herein is solely for information purposes and does not represent a commitment by TEKTELIC or its representatives TEKTELIC has prepared the information contained in this document solely for use by its employees agents and customers Dissemination of this information and or concepts to other parties is prohibited without the prior written consent of TE...

Page 2: ...orth American models 0 32 Feb 13 2018 Draft T Danshin Updated product descriptions in Table 1 and 4 0 33 Feb 14 2018 Approved T Danshin Updated MPE information 0 34 Feb 14 2018 Approved T Danshin Updated Radio Compliance Statements 0 4 Feb 15 2018 Approved S Morrison Restore Table 1 and Table 4 to show all certified models Removed Section 3 0 5 Apr 24 2019 Approved Z Herasymiuk Added North America...

Page 3: ...irect DC Power Cable Installation 15 2 7 RF Cable Installation 16 2 8 Copper Ethernet Cable Installation 16 2 9 Proposition 65 Statement 16 3 Radio Compliance Statements 17 4 Description du produit 18 4 1 aperçu 18 4 2 Interfaces physiques 20 4 3 Spécifications 22 5 Installation 24 5 1 Précautions de sécurité 24 5 2 Déballage et inspection 25 5 3 Équipement pour l installation 25 5 4 Montage de la...

Page 4: ...Kona Macro User Guide T0005158_UG Version 0 6 TEKTELIC Communications Inc Confidential Page 4 of 32 6 déclarations de conformité radio 31 ...

Page 5: ...gion Mode T0005129 LTE Yes North America FDD T0005130 LTE No Europe TDD T0005131 LTE Yes Europe TDD T0005169 LTE No China 470 FDD T0005179 LTE Yes China 470 FDD T0005180 LTE No China 780 TDD T0005181 LTE Yes China 780 TDD T0005182 LTE No Japan TDD T0005183 LTE Yes Japan TDD T0005184 LTE No Singapore TDD T0005185 LTE Yes Singapore TDD T0005186 LTE No Australia TDD T0005187 LTE Yes Australia TDD T00...

Page 6: ... TDD T0005272 LTE Yes Taiwan TDD T0005273 No No Australia 2 FDD T0005274 No Yes Australia 2 FDD T0005275 LTE No Australia 2 FDD T0005276 LTE Yes Australia 2 FDD T0005277 No No Australia 2 TDD T0005278 No Yes Australia 2 TDD T0005279 LTE No Australia 2 TDD T0005280 LTE Yes Australia 2 TDD T0006031 No No North America 2 FDD T0006032 No Yes North America 2 FDD T0006033 LTE No North America 2 FDD T000...

Page 7: ...on 0 6 TEKTELIC Communications Inc Confidential Page 7 of 32 Figure 1 Kona Macro Gateway Common Dimensions 1 2 Physical Interfaces Figure 2 illustrates the bulkhead layout for the Kona Macro Gateway All models share the same bulkhead layout ...

Page 8: ...l other connectors must be terminated with mating connectors or covered with the supplied protective cap when not in use in order to be water tight Connector types and their mating connectors are listed in Table 2 Table 2 Kona Macro Gateway Interface Connector Types Interface Connector Type Mating Connector LoRa Antenna Ports N Type female Industry standard N Type male DC Power 2 pin CPC Protectiv...

Page 9: ...e 3 Kona Macro Gateway Specifications Attribute Specification Dimensions 222 2mm 8 7 wide x 101mm 4 0 deep x 287 3mm 11 3 tall Weight 5 1 kg 11 3 lbs Operating Temperature 40 C to 60 C 40 F to 140 F at sea level Including solar loading Relative Humidity 10 to 100 Operating Altitude 60 m to 4 000 m 197 ft to 13 123 ft Power Input Direct DC 48 VDC nominal 37 to 57 VDC operating range Positive or neg...

Page 10: ...surge suppression on the Direct DC power port the Copper Ethernet port and the LoRa RF antenna port The primary lightning protectors have the ability to bridge the interface to chassis isolation boundary during over voltages Ensure that the Protective Earth Ground connection is always in place Ensure that the Kona Macro Gateway is secured to eliminate any physical hazard to people or property The ...

Page 11: ...ion when possible 3 Do not discard the shipping box or foam inserts as they will be required if a unit is returned for repair or re configuration 2 3 Required Equipment for Installation The following tools are required to install the Kona Macro Gateway module 1 A 6 point metric socket set and torque wrench drive 2 Anti oxidant compound NO OX ID Penetrox Noalox Ox Gard or equivalent 3 A small wire ...

Page 12: ...he mounting bracket is a single part that bolts to the back surface of the Gateway using supplied hardware four M6x1 0 14 mm bolts with flat and star lock washers as illustrated in Figure 4 The Gateway module must be oriented with the connector bulkhead facing down towards earth Mounting screw location Mounting screw location Mounting screw location Mounting screw location ...

Page 13: ...e is as follows 1 Bolt the wall mounting bracket to the Gateway module using the supplied bolts and washers 2 Install 2 site supplied M8 bolts into the wall at 139 7 mm 5 5 center spacing leaving the bold heads protruding with a 2mm gap from the wall surface 3 Hang the Kona Macro Gateway with bracket from the two bolts by inserting the keyhole slots at the top of the bracket onto the 2 bolts and t...

Page 14: ...Gateway grounding system shall follow local and national electrical codes The Protective Earth Ground conductor terminated at the double hole lug point is mandatory and must be the first connection made to the Kona Macro Gateway during installation Proper routing and termination of this cable is key to robust lightning withstand performance in high susceptibility installations every effort shall b...

Page 15: ...he direct DC power input is isolated from chassis earth with the exception of the primary surge suppressors One lead of the DC power feed is normally earth referenced external to the Kona Macro Gateway usually at the power source by convention The DC power cable shall be rated for outdoor application according to local and national electrical codes The CPC direct DC connector shall be as specified...

Page 16: ...Kona Macro Gateway 2 8 Copper Ethernet Cable Installation The Kona Macro Gateway Ethernet port may be used on a temporary basis for commissioning and maintenance or may be permanently connected for backhaul When the port is not in use the weatherproof protective cap must be installed When the port is permanently connector for backhaul the proper water tight mating connector specified in Table 2 mu...

Page 17: ...TV technician for help To comply with FCC IC RF exposure limits for general population uncontrolled exposure the antennas used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter This product must be installed by professional trained RF technicians Ind...

Page 18: ...4 Modèles de Kona Macro Code de produit Modem Géolocalisation Région Mode T0005129 LTE Yes North America FDD T0005130 LTE No Europe TDD T0005131 LTE Yes Europe TDD T0005169 LTE No China 470 FDD T0005179 LTE Yes China 470 FDD T0005180 LTE No China 780 TDD T0005181 LTE Yes China 780 TDD T0005182 LTE No Japan TDD T0005183 LTE Yes Japan TDD T0005184 LTE No Singapore TDD T0005185 LTE Yes Singapore TDD ...

Page 19: ...aiwan TDD T0005272 LTE Yes Taiwan TDD T0005273 No No Australia 2 FDD T0005274 No Yes Australia 2 FDD T0005275 LTE No Australia 2 FDD T0005276 LTE Yes Australia 2 FDD T0005277 No No Australia 2 TDD T0005278 No Yes Australia 2 TDD T0005279 LTE No Australia 2 TDD T0005280 LTE Yes Australia 2 TDD T0006031 No No North America 2 FDD T0006032 No Yes North America 2 FDD T0006033 LTE No North America 2 FDD...

Page 20: ...LIC Communications Inc Confidential Page 20 of 32 Figure 7 Kona Macro Gateway Dimensions communes 4 2 Interfaces physiques Figure 8 illustre la disposition de la cloison de la Kona Macro Gateway Tous les modèles partagent la même disposition de cloison ...

Page 21: ...terminés avec des connecteurs correspondants ou recouverts avec le capuchon de protection fourni lorsqu ils ne sont pas utilisés pour être étanches à l eau Les types de connecteurs et leurs connecteurs correspondants sont répertoriés dans Table 5 Table 5 Kona Macro Gateway Types de connecteurs d interface Interface Type de connecteur Connecteur compatible Ports d antenne LoRa N Type femelle Standa...

Page 22: ...ions de Kona Macro Gateway sont répertoriées dans Table 6 Table 6 Kona Macro Gateway Spécifications Attribute Spécifications Dimensions 222 2mm 8 7 large x 101mm 4 0 Profond x 287 3mm 11 3 grand Poids 5 1 kg 11 3 lbs Température de fonctionnement 40 C à 60 C 40 F à 140 F au niveau de la mer Y compris le chargement solaire Humidité relative 10 to 100 Altitude de fonctionnement 60 m to 4 000 m 197 f...

Page 23: ...Version 0 6 TEKTELIC Communications Inc Confidential Page 23 of 32 FCC Pt 15 RSS 247 EN 301 489 1 FCC Pt 27 North American 2 variante seulement Protection contre les surtensions Toutes les interfaces sont protégées aux niveaux primaires ...

Page 24: ...serelle Kona Macro Gateway est correctement terminée avant de connecter toute autre interface La passerelle Kona Macro Gateway contient une suppression de surtension de foudre primaire sur le port d alimentation CC direct le port Ethernet cuivre et le port d antenne RF LoRa Les parafoudres primaires ont la capacité de relier l interface à la limite d isolation du châssis pendant les surtensions As...

Page 25: ...et signaler tout dommage important à TEKTELIC 2 Le déballage doit être effectué dans un endroit propre et sec lorsque cela est possible 3 Ne jetez pas la boîte d expédition ou les inserts en mousse car ils seront nécessaires si une unité est retournée pour réparation ou reconfiguration Required 5 3 Équipement pour l installation Les outils suivants sont requis pour installer le module Kona Macro G...

Page 26: ...ue qui se boulonne sur la surface arrière de la passerelle à l aide de la quincaillerie fournie quatre boulons M6x1 0 14 mm avec rondelles de blocage plates et en étoile comme illustré dans Figure 10 Le module passerelle doit être orienté avec la cloison du connecteur vers le bas vers la terre Emplacement de la vis de montage Emplacement de la vis de montage Emplacement de la vis de montage Emplac...

Page 27: ... suivante 1 Visser le support de montage mural au module de passerelle à l aide des boulons et des rondelles fournis 2 Installez 2 boulons M8 fournis dans le mur à un espacement central de 139 7 mm 5 5 laissant les têtes en saillie avec un espace de 2 mm de la surface du mur 3 Accrochez la Kona Macro Gateway avec le support des deux boulons en insérant les fentes en trou de serrure au sommet du su...

Page 28: ...rre Kona Macro Gateway doit être conforme aux codes électriques locaux et nationaux Le conducteur de terre de protection terminé au point de cosse à double trou est obligatoire et doit être la première connexion faite à la Kona Macro Gateway pendant l installation Un routage et une terminaison adéquats de ce câble sont la clé d une performance de tenue à la foudre robuste dans les installations à ...

Page 29: ...ecte est isolée du châssis terre à l exception des suppresseurs de surtension primaires Une dérivation de l alimentation en courant continu est normalement reliée à la terre à l extérieur de la Kona Macro Gateway généralement à la source d alimentation par convention Le câble d alimentation CC doit être conçu pour une application extérieure conformément aux codes électriques locaux et nationaux Le...

Page 30: ... procédures d enregistrement décrites par le fournisseur de ce système de bande Notez que l antenne du modem 3G 4G est interne à la Kona Macro Gateway 5 8 Installation du câble Ethernet en cuivre Le port Ethernet Kona Macro Gateway peut être utilisé temporairement pour la mise en service et la maintenance ou peut être connecté en permanence pour le backhaul Lorsque le port n est pas utilisé le cap...

Page 31: ...z la distance entre l équipement et le récepteur Connectez l équipement à une prise d un circuit différent de celui auquel le récepteur est connecté Consulter le revendeur ou un technicien radio TV expérimenté pour obtenir de l aide Pour respecter les limites d exposition RF FCC IC pour la population générale exposition incontrôlée les antennes utilisées pour cet émetteur doivent être installées d...

Page 32: ...z toujours une distance de séparation d au moins 13 8 pouces 35 cm de toute antenne connectée Avant de réparer le produit l antenne ou les câbles désactivez la fonction de transmission ou l alimentation de l unité si vous devez vous rapprocher de la distance de séparation minimale Ce produit doit être installé par des techniciens RF qualifiés ...

Reviews: