2.2.2 RF Output Antenna Connector 
 

! CAUTION !   
 
When operating, high RF Voltages are present on this connector. Always ensure when making 
connections here, or working on any load connected, that the Transmitter’s front panel Supply 
Disconnector is switched to ‘off’ (i.e. at O) and is preferably padlocked in that position.

 

 
This is a 50

 7-16 coaxial socket on the E2025 Combiner Unit’s output directional coupler (at the top 

rear  of  the  Transmitter).  Care  must  be  taken  to  use  adequately  rated  (at  maximum  ambient 
temperature) low loss cable for the lead to the antenna or load 
 
 
2.2.3 RF Input Exciter/Drive(s) Connectors 
 

! CAUTION !   
 
When operating, high RF Voltages may be present on these connectors.  Always ensure when 
making  connections  here,  or  working  on  any  load  connected,  that  the  drive  source(s)  to  the 
Transmitter are switched off or safely muted. 
 

These are three 50

 TNC coaxial sockets at the centre rear of the E2024 Splitter/Drive Changeover 

Unit.  Socket  SK08    (Drive  A)  is  for  connection  a  single  Exciter/Drive’s  RF  Output.  When  dual  drive 
changeover is supplied, socket SK06 (Drive B) is used for connection to the second Exciter/Drive’s RF 
Output.  In  this  case,  socket  SK07  (Load)  is  used  for  connection  a  50

  Exciter/Drive  dummy  load, 

normally situated in the section of the rack where the Exciter/Drives are fitted. 
 
2.2.4 Safety Interlock Connector 
 
This is a removable, 2 Way, 5.08mm screw terminal block PL13 at the rear of the E2024 Splitter/Drive 
Changeover  Unit.  A  shorting  link  has  to  be  made  between  the  terminals  to  de-mute  the  Transmitter 
(the  front  panel  INTERLOCK  EXT.  MUTE  display  goes  from  red  to  green  when  the  terminals  are 
linked).  If  there  are  no  external  safety  interlock  switches,  a  short  direct  link  is  made,  this  being  the 
state in  which  the connector is normally supplied. If connections need to be made to  external safety 
switches, this link is removed and the switches are  wired in a series loop  to the  connector so  that if 
any switch opens, the link is broken. 
 

! CAUTION ! 
 
For  the  safety  interlocks  to  work  correctly,  the  external  switches  and  link  wiring  must  ‘float’ 
(i.e. must not be grounded at any point).

 The total loop resistance should not exceed approximately 

100

.  The  external  wiring  may  also  be  ferrite  loaded  for  emc  requirements. 

No  external  voltages 

should be applied to this connector.

 

 
2.2.5 RF Output Monitor Connector 
 
This is a 50

 BNC coaxial socket SK01 on the left-hand side of the E2025 Combiner Unit front panel. 

This provides an harmonically filtered sample of the Transmitter’s forward output power at a level, into 
50

, approximately 64dB below the power being delivered into the load (e.g. approximately 0.4mW for 

1kW being delivered). This connector is for test purpose only with the test equipment and lead being 
disconnected when not in use. 

NOTE that the levels of any harmonics present are not necessarily 

equal to those at the antenna.

 

 
2.2.6 Drive A/B Monitor and Control Connectors 
 
These are two identical 9 Way D sockets SK03 and SK06 at the rear of the E2023 Controller unit. 
These are used to enable one or two Exciter/Drive(s) to be monitored and controlled by the E2023 
(with two Exciter/Drives this enables automatic dual Exciter/Drive changeover). Multi-core screened 
cable, not exceeding 3 metres in length, should be used for the interconnecting leads. 

Содержание S7601

Страница 1: ...5 S7601 S7602 500W 1kW 2kW Low Power FM Transmitters Installation and Operation Issue 8 S7600 00MA 08 May 2015 Eddystone Broadcast Ltd 26 Arden Rd Arden Forest Industrial Estate Alcester Warwickshire...

Страница 2: ...Print Date 12 05 15 Page 2 of 32 S7600 00MA 08 Intentional blank page...

Страница 3: ...ote Control DTE Connector Page 15 2 2 8 Second Transmitter Remote Control Connector Page 16 2 2 9 Mains Supply Output Connectors Page 16 2 2 10 RS232 Serial Control and Monitor COM Connector Page 17 2...

Страница 4: ...ol and Monitoring Page 31 3 4 2 Muting and Reduced Power Operation Page 31 Bound at Rear S76005 01 500W Front and Rear Panel Views S7600 04GA S76005 02 500W Front and Rear Panel Views S7600 03GA S7601...

Страница 5: ...ing can be provided as an option to direct all of one Transmitter s power to the antenna The key feature of The S7600 series is its ability to remain on air The use of multiple Amplifier and Power Sup...

Страница 6: ...padlocked in the off position to ensure that the transmitter remains off whilst work is being carried out at the antenna etc Each E2088 E2322 Power Supply Module has its own forced air cooling output...

Страница 7: ...ternal splitter and the other to a dumping load This dumping load has to be provided externally to the E2024 whenever two Exciters are supplied and the Exciter not in use is required to remain active...

Страница 8: ...00W Max 2 off E2021 XX 1 off E2088 01 or E2322 01 Single E2023 XX Single E2024 03 Single E2025 03 S76005 02 500W Max 2 off E2021 XX 2 off E2088 01 or E2322 01 Single E2023 XX Single E2024 03 Single E2...

Страница 9: ...for S76005 Power High setting Adjustable at least 400W to 1kW for S7601 Power Low setting Adjustable at least 600W to 1kW for S7601 Power High setting Adjustable at least 800W to 2kW for S7602 Power...

Страница 10: ...on all modules Dimensions Height 12U S76005 and S7601 14U S7602 Width to fit standard 19in rack Depth to fit standard 600mm deep rack Environmental Ambient Temperature operating 5 to 50 deg C Ambient...

Страница 11: ...into the Transmitter with its locking lever engaged do not try to force these modules home if they appear difficult to insert fully check the connectors at the rear of the module 2 1 PHYSICAL DIMENSI...

Страница 12: ...smd holders Littelfuse R451 500 For protection of control circuits within E2021 Amplifiers and E2025 Combiner Unit 2 8 16A T HBC 5x32mm x1 in Fuses For protection of internal dc supply leads to and h...

Страница 13: ...erall cable armoured type SY flexible steel armoured cable preferred and not mounted in a conduit with other supply cables Two double pole 16A C rated MCBs must be provided at the supply distribution...

Страница 14: ...the Transmitter the front panel INTERLOCK EXT MUTE display goes from red to green when the terminals are linked If there are no external safety interlock switches a short direct link is made this bei...

Страница 15: ...ngeover only requires one of the two status monitor inputs for operation the other must be connected to ground 2 2 7 Parallel standard or RS232 Serial Remote Control DTE Connector This is a 9 Way D pl...

Страница 16: ...hese inputs are protected against constant application of up to 12V dc directly applied Note that they are only active when the associated E2024 Auto Mute Start switch is in the Auto position and have...

Страница 17: ...ndard RJ45 connector SK08 mounted in an additional screened box fitted to the rear of the E2023 02 or E2023 04 Control Unit This enables all the control and monitoring detailed in Section 2 4 to be pe...

Страница 18: ...printed circuit board right hand side CAUTION Ensure that the front panel Supply Disconnector is switched to off i e at O and is preferably padlocked in that position 16A T HBC 5x32mm x1 in Fuses One...

Страница 19: ...is as follows 1 Ensure the Transmitter has been installed as detailed in sections 2 1 and 2 2 and that the E2024 Splitter Drive Changeover front panel switches are set to MUTE and either SELECT A or S...

Страница 20: ...adjusted by a preset control inside the E2025 Combiner Unit To access this control slide the E2025 forwards after removing its front fixing screws and single rear fixing screw taking care not to strai...

Страница 21: ...ely good antenna system and with the E2025 REV led still green 2 3 4 Serial Remote Control Baud Rate Setting The operating Baud rate and be viewed and changed if required by pressing MODE on the E2023...

Страница 22: ...onitor requests are initiated by the remote control unit PC the E2023 never outputs any serial data via the COM PORT connector unless requested to by that unit The remote control unit always sends a s...

Страница 23: ...mp22_Stat Revert amplifier 22 status 46 F Amp23_Stat Revert amplifier 23 status 47 G Amp24_Stat Revert amplifier 24 status 48 H Amp25_Stat Revert amplifier 25 status 49 I Amp26_Stat Revert amplifier 2...

Страница 24: ...ct Display Sign 2B 2D Direct Display Decimal point 2E Direct Display Blank 00 NUL Direct Display Less than 3C Most meanings are general A string of fourteen information bytes would normally contain se...

Страница 25: ...4 Tx power auto start mute status M S Tx_Data15 Tx power auto high lo setting status H L Tx_Data16 Tx status 8 bit EOR checksum of 2 15 inc only Reverted Drive Data Block 15 extra bytes reverted in re...

Страница 26: ...k 0 to 9 inc Op_Data15 Output Tx Type 0 500W 1 6 1kW 6kW 7 5kW S7605C 8 9 8kW 9kW 10kW Op_Data16 Output data 8 bit EOR checksum of 2 15 inc only Reverted Amplifier Data Block 15 extra bytes reverted i...

Страница 27: ...ed Amber indicates forward power muted Green indicates normal operation REV LED Display Red indicates reverse power to module in excess of approximately 30W i e 10dB return loss relative to maximum mo...

Страница 28: ...nsmitter s output forward power reverse power state and combiner heatsink temperature MODE Membrane Switch To select other Controller functions modes such as Amplifier module monitoring Membrane Switc...

Страница 29: ...lay and Adjustable Pot 20T Green LED indicates low power output setting selected and adjacent pot can be used to directly set output power level The HIGH POWER LED will be off TEMP LED Display Red ind...

Страница 30: ...E2023 mode must be left in MAIN to ensure that the Modules continue to be polled and their latest status recorded section 2 4 3 To display individual E2021 statuses press MODE then the soft key on th...

Страница 31: ...hing for approximately 30 seconds to indicate that no actual changeover can take place during this settling period An automatic changeover can then occur if the selected Exciter Drive fails by either...

Страница 32: ...be over ridden by the rear panel Mute Transmitter Input see section 2 2 8 the first part of the display then showing ext Mute The order of priority is thus I Lock then ext Mute then Start Mute as sel...

Отзывы: