Each lead terminates in a separate 9 Way free D plug at the E2023 end which is wired as follows :- 
 

Pin 1 

RS232 Data from Drive (not enabled) 

Pin 2 

Ground 

Pin 3 

Prefer Drive from Rem. Control 
Momentary low > approx. 1sec 

Pin 4 

Slow Status Monitor from Drive 
Continuous low >2secs registers ‘good’ 
Continuous high >10secs registers ‘fail’ 

Pin 5 

Fast Status Monitor from Drive 
Continuous low >2secs registers ‘good’ 
Continuous high >2secs registers ‘fail’ 

Pin 6 

RS232 Data to Drive (not enabled) 

Pin 7 

Ground 

Pin 8 

Ground 

Pin 9 

Mute/demute to Drive 
Continuous low to mute 

 
Each input (pins 3, 4, 5) is internally ‘pulled up’ to +5V through 12k

 and must be fed from a voltage 

free source of less than 1k

 to ground for a low state (open-circuit for a high state). These inputs are 

protected against constant application of up to 

±

12V dc directly applied. 

 
The mute/demute output (pin 9) is an ‘open collector’ NPN, silicon low saturation switching transistor 
suitable for driving loads from +5V to +24V dc with maximum currents of 10mA. The low state output 
impedance is approximately 10

 
These connections are  wired in accordance  with the monitor and control requirements of the type of 
Exciter/Drive(s) supplied and normally, not all the pins will need to be connected. Pin 3, if used, is for 
connection to a remote control and monitoring system. This enables selection of a particular drive to 
be preferred (forced) remotely by momentarily pulling this line to ground. 
 
If  automatic  dual  Exciter/Drive  changeover  only  requires  one  of  the  two  status  monitor  inputs  for 
operation, the other must be connected to ground. 
 
2.2.7 Parallel (standard) or RS232 Serial Remote Control DTE Connector 
 
This is a 9 Way D plug PL04 at the rear of the E2023 Controller unit. It is used to enable various forms 
of  remote  control  and  monitoring,  possibly  requiring  additional  external  units.  Multi-core  screened 
cable, not exceeding 3 metres in length, should be used for the interconnecting lead. 
 
The lead terminates in a 9 Way free D socket at the E2023 end which is wired as follows :- 
 

 

Parallel (standard) 

Serial RS232 

Pin 1 

Power Output Low (app.–2dB rel. set output) 

Not connected 

Pin 2 

Power Output Fail (app. –12dB rel. max o/p) 

Received Data (to E2023) 

Pin 3 

Reverse Power High (app. 13, 25 or 50W) 

Transmit Data  (from E2023)  

Pin 4 

Combiner Temp. High (app. +100deg.C) 

Not Connected 

Pin 5 

Ground 

Ground 

Pin 6 

Fan/Cooling System Fail 

Not Connected 

Pin 7 

System Normal 

Not Connected 

Pin 8 

Drive A/B Selected  

Not Connected 

Pin 9 

Drive Changeover on Auto  

Not Connected 

 
The parallel outputs are  ‘open collector’ NPN, silicon low saturation switching transistors suitable for 
driving loads from +5V to +24V dc with maximum currents of 10mA. The low state output impedance 
is approximately 100

. Each output is protected against constant application of up to 

±

5V dc directly 

applied. A normal (non-faulty) condition is indicated by the output pin being pulled to ground (i.e. low 
state) by the switching transistor. Drive A selected and Drive C/O on Auto are similarly indicated. Note 
that the serial option requires an additional internal link lead, which re-directs the serial remote control 
from the front panel COM port to the rear panel DTE connector (pins 2, 3, 5 only). 

Содержание S7601

Страница 1: ...5 S7601 S7602 500W 1kW 2kW Low Power FM Transmitters Installation and Operation Issue 8 S7600 00MA 08 May 2015 Eddystone Broadcast Ltd 26 Arden Rd Arden Forest Industrial Estate Alcester Warwickshire...

Страница 2: ...Print Date 12 05 15 Page 2 of 32 S7600 00MA 08 Intentional blank page...

Страница 3: ...ote Control DTE Connector Page 15 2 2 8 Second Transmitter Remote Control Connector Page 16 2 2 9 Mains Supply Output Connectors Page 16 2 2 10 RS232 Serial Control and Monitor COM Connector Page 17 2...

Страница 4: ...ol and Monitoring Page 31 3 4 2 Muting and Reduced Power Operation Page 31 Bound at Rear S76005 01 500W Front and Rear Panel Views S7600 04GA S76005 02 500W Front and Rear Panel Views S7600 03GA S7601...

Страница 5: ...ing can be provided as an option to direct all of one Transmitter s power to the antenna The key feature of The S7600 series is its ability to remain on air The use of multiple Amplifier and Power Sup...

Страница 6: ...padlocked in the off position to ensure that the transmitter remains off whilst work is being carried out at the antenna etc Each E2088 E2322 Power Supply Module has its own forced air cooling output...

Страница 7: ...ternal splitter and the other to a dumping load This dumping load has to be provided externally to the E2024 whenever two Exciters are supplied and the Exciter not in use is required to remain active...

Страница 8: ...00W Max 2 off E2021 XX 1 off E2088 01 or E2322 01 Single E2023 XX Single E2024 03 Single E2025 03 S76005 02 500W Max 2 off E2021 XX 2 off E2088 01 or E2322 01 Single E2023 XX Single E2024 03 Single E2...

Страница 9: ...for S76005 Power High setting Adjustable at least 400W to 1kW for S7601 Power Low setting Adjustable at least 600W to 1kW for S7601 Power High setting Adjustable at least 800W to 2kW for S7602 Power...

Страница 10: ...on all modules Dimensions Height 12U S76005 and S7601 14U S7602 Width to fit standard 19in rack Depth to fit standard 600mm deep rack Environmental Ambient Temperature operating 5 to 50 deg C Ambient...

Страница 11: ...into the Transmitter with its locking lever engaged do not try to force these modules home if they appear difficult to insert fully check the connectors at the rear of the module 2 1 PHYSICAL DIMENSI...

Страница 12: ...smd holders Littelfuse R451 500 For protection of control circuits within E2021 Amplifiers and E2025 Combiner Unit 2 8 16A T HBC 5x32mm x1 in Fuses For protection of internal dc supply leads to and h...

Страница 13: ...erall cable armoured type SY flexible steel armoured cable preferred and not mounted in a conduit with other supply cables Two double pole 16A C rated MCBs must be provided at the supply distribution...

Страница 14: ...the Transmitter the front panel INTERLOCK EXT MUTE display goes from red to green when the terminals are linked If there are no external safety interlock switches a short direct link is made this bei...

Страница 15: ...ngeover only requires one of the two status monitor inputs for operation the other must be connected to ground 2 2 7 Parallel standard or RS232 Serial Remote Control DTE Connector This is a 9 Way D pl...

Страница 16: ...hese inputs are protected against constant application of up to 12V dc directly applied Note that they are only active when the associated E2024 Auto Mute Start switch is in the Auto position and have...

Страница 17: ...ndard RJ45 connector SK08 mounted in an additional screened box fitted to the rear of the E2023 02 or E2023 04 Control Unit This enables all the control and monitoring detailed in Section 2 4 to be pe...

Страница 18: ...printed circuit board right hand side CAUTION Ensure that the front panel Supply Disconnector is switched to off i e at O and is preferably padlocked in that position 16A T HBC 5x32mm x1 in Fuses One...

Страница 19: ...is as follows 1 Ensure the Transmitter has been installed as detailed in sections 2 1 and 2 2 and that the E2024 Splitter Drive Changeover front panel switches are set to MUTE and either SELECT A or S...

Страница 20: ...adjusted by a preset control inside the E2025 Combiner Unit To access this control slide the E2025 forwards after removing its front fixing screws and single rear fixing screw taking care not to strai...

Страница 21: ...ely good antenna system and with the E2025 REV led still green 2 3 4 Serial Remote Control Baud Rate Setting The operating Baud rate and be viewed and changed if required by pressing MODE on the E2023...

Страница 22: ...onitor requests are initiated by the remote control unit PC the E2023 never outputs any serial data via the COM PORT connector unless requested to by that unit The remote control unit always sends a s...

Страница 23: ...mp22_Stat Revert amplifier 22 status 46 F Amp23_Stat Revert amplifier 23 status 47 G Amp24_Stat Revert amplifier 24 status 48 H Amp25_Stat Revert amplifier 25 status 49 I Amp26_Stat Revert amplifier 2...

Страница 24: ...ct Display Sign 2B 2D Direct Display Decimal point 2E Direct Display Blank 00 NUL Direct Display Less than 3C Most meanings are general A string of fourteen information bytes would normally contain se...

Страница 25: ...4 Tx power auto start mute status M S Tx_Data15 Tx power auto high lo setting status H L Tx_Data16 Tx status 8 bit EOR checksum of 2 15 inc only Reverted Drive Data Block 15 extra bytes reverted in re...

Страница 26: ...k 0 to 9 inc Op_Data15 Output Tx Type 0 500W 1 6 1kW 6kW 7 5kW S7605C 8 9 8kW 9kW 10kW Op_Data16 Output data 8 bit EOR checksum of 2 15 inc only Reverted Amplifier Data Block 15 extra bytes reverted i...

Страница 27: ...ed Amber indicates forward power muted Green indicates normal operation REV LED Display Red indicates reverse power to module in excess of approximately 30W i e 10dB return loss relative to maximum mo...

Страница 28: ...nsmitter s output forward power reverse power state and combiner heatsink temperature MODE Membrane Switch To select other Controller functions modes such as Amplifier module monitoring Membrane Switc...

Страница 29: ...lay and Adjustable Pot 20T Green LED indicates low power output setting selected and adjacent pot can be used to directly set output power level The HIGH POWER LED will be off TEMP LED Display Red ind...

Страница 30: ...E2023 mode must be left in MAIN to ensure that the Modules continue to be polled and their latest status recorded section 2 4 3 To display individual E2021 statuses press MODE then the soft key on th...

Страница 31: ...hing for approximately 30 seconds to indicate that no actual changeover can take place during this settling period An automatic changeover can then occur if the selected Exciter Drive fails by either...

Страница 32: ...be over ridden by the rear panel Mute Transmitter Input see section 2 2 8 the first part of the display then showing ext Mute The order of priority is thus I Lock then ext Mute then Start Mute as sel...

Отзывы: