5
BOTTOM SOLAR
COIL RETURN
TOP COIL
SUPPLY
BOTTOM SOLAR
COIL SUPPLY
T+P VALVE
TOP COIL
RETURN
COLD
WATER IN
HOT WATER
OUT
BOTTOM HEATING COIL
FOR SOLAR
BOTTOM COIL
3/8" ID THERMAL WELL
TOP HEATING COIL
FOR BACKUP
TOP COIL
3/8" ID THERMAL WELL
DUAL COIL UNITS
1/2" NPT RECIRC.
RETURN PORT
DRAIN VALVE
3/8" ID
THERMAL WELL
4" X 10"
ELECTRICAL BOX
TYPICAL ALL
ELECTRIC BACKUP UNITS
1.5
Heat exchanger coil outputs
Model
Max. Recovery
Max. Recovery
Water Flow
Pressure Drop
(gal/hr.)
(gal/hr.)
Through Coil
Through Coil
Top Coil
Bottom Coil
(gal./min.)
(Ft. Water)
115 Gal. Units
190
214
10.0
3.9
80 Gal. Units
180
214
10.0
3.6
60 Gal. Units
185
214
10.0
3.5
Note: All Ratings are based on 180 degree F boiler water supply and 50 degree F cold Water inlet.
In the interest of continuous improvement, specifications are subject to change without notice.
For all units with 3500 watt Electric Backup
Model First Hour Rating (gal/hr.) Continuous Rating (gal/hr.)
140 F
115 F
140 F
115 F
115 Gal. Units
73.9
80.0
15.9
22.0
80 Gal. Units
55.9
62.0
15.9
22.0
60 Gal. Units
45.9
52.0
15.9
22.0
DuAl COIl uNITS
ElECTRIC bACKup uNITS
Table 2