Solar Electric Tank

Electric Connections
Solar electric hot water heater includes 240 VAC thermostat and 3500 watt element.
See Schematic

Connect Electric Heating Element
Before any electrical connections are made, verify water heater is full of water and valve in cold water supply line is open. 

Solar water heater is supplied with single electric heating element backup system.  Thermostat incorporates manual reset 

temperature-limiting device.  Refer to "Troubleshooting Guide" section for manual reset operation. Turn off all power 

related to heating system before proceeding with electrical connections.  Any and all wiring shall be sized and installed to 

satisfy voltage and amperage used.  Water heater must be well grounded. Green ground screw is provided at electrical 

connection point for connecting ground wire.  All wiring shall be done in accordance with all applicable local and state 

codes.

Adjusting Thermostat Temperature Dial 
Minimum potable water temperature can be changed by adjusting thermostat.  Before any work is done on water heater, 

disconnect all power to the water heater and heat source (solar collector) by opening the switch(s) at main electrical 

circuit breaker or fuse box. Remove cover and fold insulation outward away form control. Adjust thermostat dial using 

screwdriver until minimum acceptable temperature is achieved.  Rotate temperature dial clockwise to increase water 

temperature. Rotate thermostat dial counter-clockwise to decrease temperature setting.  See Figure 6 for temperature 

settings.
Thermostat has been factory preset to 120°F (49°C). Remember lower temperature settings are more energy efficient. 

Replace insulation make sure control is well covered and plastic terminal shield has not displaced.  Replace access panel. 

Water heater is now ready for operation.

FIGURE 9

N

Ground 

unit per  

local code

L

Содержание H2O60DE

Страница 1: ...I80DE H2 OI115D H2 OI115E H2 OI115DE An ISO 9001 2008 Certified Company ECR International Inc 2201 Dwyer Avenue Utica NY 13501 web site www ecrinternational com Information and specifications outlined...

Страница 2: ...is operating Do not touch any components unless they are cool Failure to follow all instructions in the proper order can cause personal injury or death Read all instructions including all those contai...

Страница 3: ...defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product Indicates a presence o...

Страница 4: ...180 H2O080E 80 8 0 56 0 28 0 1 NPT 150 145 H2O60E 60 8 3 62 3 23 5 1 NPT 150 135 Dual Coil No Electric Backup H2O115D 115 7 4 8 9 74 0 28 0 1 NPT 150 205 H2O80D 80 7 4 8 0 56 0 28 0 1 NPT 150 175 H2O...

Страница 5: ...w Pressure Drop gal hr gal hr Through Coil Through Coil Top Coil Bottom Coil gal min Ft Water 115 Gal Units 190 214 10 0 3 9 80 Gal Units 180 214 10 0 3 6 60 Gal Units 185 214 10 0 3 5 Note All Rating...

Страница 6: ...l based on the expected water usage for the given site The average residence with one shower or more will require a Model 40 or larger The Model 30 should only be considered for residences with minima...

Страница 7: ...e The water heater is controlled with an additional zone valve Select a valve with a low pressure drop and assure minimum flow with adequate pipe sizing B Priority or Non Priority for Hot Water 1 Opti...

Страница 8: ...e boiler system during service 2 Unions Allows for easy locating or removal 3 Vacuum breaker Protects the water heater from collapse if a hot tank is valved off to service other components in the syst...

Страница 9: ...the domestic water system 2 Position the water heater in the final location 3 Connect the cold water supply piping Install piping onto cold inlet connection Connect to cold water supply connection usi...

Страница 10: ...hat uses Zone Valves refer to Figure 3 The water heater connection labeled BOILER SUPPLY should be piped to the boiler supply piping after the air purger and before the space heating circulator Mount...

Страница 11: ...11 Figure 2 Typical Mixing Valve Install Figure 1 Domestic Water Piping Pipe Relief Valve Discharge to within 6 of floor see Section III Notes...

Страница 12: ...Discharge to within 6 of floor see Section III Notes Pipe Relief Valve Discharge to within 6 of floor see Section III Notes Figure 3 Boiler water piping with zone circulators Figure 4 Boiler water pip...

Страница 13: ...13 Pipe Relief Valve Discharge to within 6 of floor see Section III Notes Figure 5 Figure 6 Figure 7 Pipe Relief Valve Discharge to within 6 of floor see Section III Notes...

Страница 14: ...of hot water Hot Water Can Scald Water heated to temperature for clothes washing dish washing and other sanitizing needs can scald and cause permanent injury Children elderly and infirm or physically...

Страница 15: ...temperature in the water heater If it is set too high the resulting hot water can cause painful scalding with possible serious and permanent injury The temperature at which this occurs varies with a p...

Страница 16: ...ing our ARM 4P Panel Product features include Build in transformer that will support up to 15 zones Transformer has electronic fuse protection 1 to prevent transformer overloading Data Port Terminal f...

Страница 17: ...17 BOILER T T BOILER T T BOILER T T...

Страница 18: ...All wiring shall be done in accordance with all applicable local and state codes Adjusting Thermostat Temperature Dial Minimum potable water temperature can be changed by adjusting thermostat Before a...

Страница 19: ...roblem Symptoms are identical to sediment buildup If repeated flushing does not resolve the problem chemical cleaning may be required Contact a qualified contractor VII Troubleshooting PROBLEM CAUSE S...

Страница 20: ...0 1st HOUR CONTINUOUS GAL HR GAL HR GAL HR GAL HR GAL HR GAL HR RATING RATING Boiler flow 14 gpm Boiler flow 14 gpm RATING RATING RATING RATING 1st HOUR CONTINUOUS 1st HOUR CONTINUOUS 1st HOUR CONTINU...