ECR International H2O60DE Скачать руководство пользователя страница 23

23

regulations; (d) misapplication or the use of the Product for purposes other than for which it was designed; (e) the use of parts not 

supplied or designated by ECR; (f) failure to maintain the Product free of water sediments or scale deposits; (g) components of a 

Product which are not defective, but must be replaced during the warranty period as a result of reasonable wear and tear; (h) failure 

of a component, control or component part other than a component part manufactured solely by ECR; or (i) potable water with a Ph

exceeding 8.0 or below 6.0, and/or chloride concentrations exceeding 80 parts per million (ppm). 

6. This Limited Warranty in no way can be considered as a guarantee of workmanship of an installer or repairman connected with 

the installation or repair of the Product or as imposing on ECR liability of any nature for unsatisfactory performance as a result of 

faulty workmanship in the installation or service of the Product, which liability is hereby expressly disclaimed. 

7. The furnishing of replacement parts under the terms of this Limited Warranty will apply to the original warranty period and will not 

serve to extend such period. 

8. This Limited Warranty only applies to Products installed in the United States or Canada.   

9. The remedy for breach of this Limited Warranty is expressly limited to the repair or replacement of any part found to be defective

under conditions of normal use, unless otherwise specifically set forth herein, and the remedy for breach of this Limited Warranty, 

statutory duty or by reason of tort (including, without limitation, negligence) does not extend to liability for incidental, special or 

consequential damages or losses, such as loss for the use of the material, inconvenience or loss of time.  The maximum liability of 

ECR in connection with the sale of the Product shall not in any case exceed the price of the part claimed to be defective, or the price 

of the Product if the entire Product is claimed to be defective.  This Limited Warranty is the complete and exclusive statement of 

warranty terms in regards to the Product. 

10. FOR ALL SALES NOT SUBJECT TO THE MAGNUSON-MOSS WARRANTY ACT THE FOREGOING WARRANTIES ARE 

EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, 

INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR 

PURPOSE. FOR ALL OTHER SALES, ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR ANY 

PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE PERIOD OF THIS LIMITED WARRANTY. 

PLEASE NOTE: Some states, provinces and territories do not allow the exclusion or limitation of incidental or 

consequential damages, or limitations on how long an implied warranty lasts, so the above limitations and exclusions may 

not apply to you. 

MISCELLANEOUS

1. The Magnuson-Moss Warranty Act applies to “consumer” sales as contrasted with “commercial” sales.  A consumer sale is one to

a buyer for personal, family or household purposes and not for the purpose of resale.  

2.  If any provision of this Limited Warranty shall be determined to be illegal, unconscionable or unenforceable, all other terms and 

provisions hereof shall nevertheless remain effective and shall be enforced to the fullest extent permitted by law. The warranties

made under this Limited Warranty are exclusive and may not be altered, enlarged or changed by a distributor, dealer, or other 

person whatsoever, other than pursuant to a written agreement executed by a duly authorized officer of ECR. 

3. This Limited Warranty is nontransferable and shall be for the benefit of the Original Purchaser of the Product only.  

4. This Limited Warranty gives the Original Purchaser only specific legal rights and you may have other legal rights which vary from 

state-to-state.

PROCEDURE FOR OBTAINING WARRANTY SERVICE 

1. At the time a claim is filed under this Limited Warranty the Original Purchaser must present a copy of the original sales receipt, 

and a deed, utility bill, or equivalent document evidencing both ownership of the Product and installation in the dwelling owned by 

the Original Purchaser. 

2. For prompt warranty service, notify the installer who, in turn, will notify the ECR distributor from whom such distributor purchased 

the Product.  If this action does not result in warranty service, the Original Purchaser or installer should contact ECR Customer

Service (see contact information below), giving full particulars in support of the claim. Alleged defective part or parts must be

returned through trade channels in accordance with ECR’s procedure currently in force for handling returned goods for the purpose 

of inspection or determining the cause of failure.  ECR will furnish the new part(s) to an authorized ECR distributor who, in turn, will 

furnish the part(s) to the heating contractor who installed the Product. 

ECR International, Inc. 

2201 Dwyer Avenue 

Utica, New York13504-4729 

Ph: 315/797-1310 

Customer Service Fax: 315/724-9319 

E-Mail: [email protected] 

PN 240009218 Rev. A 10/11 

-------------------------------------------------------------------------------------------------------------------------------------------

List Prices 2011

FOB Uxbridge, MA

INDIRECT WATER HEATERS

1 1/2” NPT COLD AND HOT CONNECTIONS

- HO = HIGH OUTPUT

1 1/4" NPT BOILER SUPPLY AND RETURN

HF-80-C

1899

80

54

26.5

140

HF-115-C

2616

115

72

26.5

185

HF-80-HO-C

2186

80

54

26.5

155

HF-115-HO-C

2904

115

72

26.5

200

HOT WATER STORAGE TANKS with 1 ½” NPT COLD AND HOT CONNECTIONS

HF-80-ST-C

1765

80

54

26.5

130

HF-115-ST-C

2473

115

72

26.5

190

HYDRONIC BUFFER TANKS WITH COIL (S) **

Insulated thermal buffer and hydraulic separator tanks. Used with water source heat pumps, chillers, and

low mass boilers.

-XX denotes connection size Specify 1 ¼”, 1 ½”, or 2” NPT connections.

Internal coil can be used to add heat from solar panels, remove heat, and many other applications.

Model

No.

List

Price

($)

Capacity

(gal.)

Height

(in.)

Diameter

(in.)

Ship Wt.

(lbs.)

HF-40-BT-XX with coil

1926

40

42.0

22.5

115

HF60-BT-XX with coil

2240

60

42.0

26.5

140

HF80-BT-XX with coil

2443

80

52.0

26.5

150

HF115-BT-XX with coil

2973

115

72.0

26.5

175

** Buffer tanks can be fabricated with dual coils. Add $275.00 to the single coil list price

for a second coil.

REPLACEMENT PARTS

Part

Part No.

Description

List Price

($)

T+P Relief Valve

TP-3

150 psi / 210deg. F, 4” probe,

ANSI/AGA Cert.

22.35

Thermostat

L4080

Honeywell L4080B

59.63

Thermostat Well

R-Well

3” Immersion Well, ¾”, ½” NPT

40.94

List Prices: 3/15/11 FOB Uxbridge, MA

Heat-Flo, Inc., 15 Megan Court, Uxbridge, MA 01569

Tel: 508-278-2400

Fax: 508-278-2466

www.heat-flo.com

Содержание H2O60DE

Страница 1: ...I80DE H2 OI115D H2 OI115E H2 OI115DE An ISO 9001 2008 Certified Company ECR International Inc 2201 Dwyer Avenue Utica NY 13501 web site www ecrinternational com Information and specifications outlined...

Страница 2: ...is operating Do not touch any components unless they are cool Failure to follow all instructions in the proper order can cause personal injury or death Read all instructions including all those contai...

Страница 3: ...defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product Indicates a presence o...

Страница 4: ...180 H2O080E 80 8 0 56 0 28 0 1 NPT 150 145 H2O60E 60 8 3 62 3 23 5 1 NPT 150 135 Dual Coil No Electric Backup H2O115D 115 7 4 8 9 74 0 28 0 1 NPT 150 205 H2O80D 80 7 4 8 0 56 0 28 0 1 NPT 150 175 H2O...

Страница 5: ...w Pressure Drop gal hr gal hr Through Coil Through Coil Top Coil Bottom Coil gal min Ft Water 115 Gal Units 190 214 10 0 3 9 80 Gal Units 180 214 10 0 3 6 60 Gal Units 185 214 10 0 3 5 Note All Rating...

Страница 6: ...l based on the expected water usage for the given site The average residence with one shower or more will require a Model 40 or larger The Model 30 should only be considered for residences with minima...

Страница 7: ...e The water heater is controlled with an additional zone valve Select a valve with a low pressure drop and assure minimum flow with adequate pipe sizing B Priority or Non Priority for Hot Water 1 Opti...

Страница 8: ...e boiler system during service 2 Unions Allows for easy locating or removal 3 Vacuum breaker Protects the water heater from collapse if a hot tank is valved off to service other components in the syst...

Страница 9: ...the domestic water system 2 Position the water heater in the final location 3 Connect the cold water supply piping Install piping onto cold inlet connection Connect to cold water supply connection usi...

Страница 10: ...hat uses Zone Valves refer to Figure 3 The water heater connection labeled BOILER SUPPLY should be piped to the boiler supply piping after the air purger and before the space heating circulator Mount...

Страница 11: ...11 Figure 2 Typical Mixing Valve Install Figure 1 Domestic Water Piping Pipe Relief Valve Discharge to within 6 of floor see Section III Notes...

Страница 12: ...Discharge to within 6 of floor see Section III Notes Pipe Relief Valve Discharge to within 6 of floor see Section III Notes Figure 3 Boiler water piping with zone circulators Figure 4 Boiler water pip...

Страница 13: ...13 Pipe Relief Valve Discharge to within 6 of floor see Section III Notes Figure 5 Figure 6 Figure 7 Pipe Relief Valve Discharge to within 6 of floor see Section III Notes...

Страница 14: ...of hot water Hot Water Can Scald Water heated to temperature for clothes washing dish washing and other sanitizing needs can scald and cause permanent injury Children elderly and infirm or physically...

Страница 15: ...temperature in the water heater If it is set too high the resulting hot water can cause painful scalding with possible serious and permanent injury The temperature at which this occurs varies with a p...

Страница 16: ...ing our ARM 4P Panel Product features include Build in transformer that will support up to 15 zones Transformer has electronic fuse protection 1 to prevent transformer overloading Data Port Terminal f...

Страница 17: ...17 BOILER T T BOILER T T BOILER T T...

Страница 18: ...All wiring shall be done in accordance with all applicable local and state codes Adjusting Thermostat Temperature Dial Minimum potable water temperature can be changed by adjusting thermostat Before a...

Страница 19: ...roblem Symptoms are identical to sediment buildup If repeated flushing does not resolve the problem chemical cleaning may be required Contact a qualified contractor VII Troubleshooting PROBLEM CAUSE S...

Страница 20: ...0 1st HOUR CONTINUOUS GAL HR GAL HR GAL HR GAL HR GAL HR GAL HR RATING RATING Boiler flow 14 gpm Boiler flow 14 gpm RATING RATING RATING RATING 1st HOUR CONTINUOUS 1st HOUR CONTINUOUS 1st HOUR CONTINU...

Страница 21: ...21...

Страница 22: ...nth 13th year from the original date of installation seventy five percent 75 Within the fourteenth 14th year through the fifteenth 15th year from the original date of installation eighty percent 80 Pl...

Страница 23: ...ble all other terms and provisions hereof shall nevertheless remain effective and shall be enforced to the fullest extent permitted by law The warranties made under this Limited Warranty are exclusive...

Страница 24: ...ECR International Inc 2201 Dwyer Avenue Utica NY 13504 4729 web site www ecrinternational com H2 O...