SPLIT-TYPE ROOM AIR CONDITIONER
TEST RUN
Only perform test run after you have completed the following
steps:
Electrical Safety Checks – Confirm that the unit’s electrical
system is safe and operating properly
Gas Leak Checks – Check all flare nut connections and confirm
that the system is not leaking
Confirm that gas and liquid (high and low pressure) valves are
fully open.
You should perform the Test Run for at least 30 minutes.
Connect power to the unit.
Press the ON/OFF button on the remote control to turn it on.
Press the MODE button to scroll through the following
functions, one at a time:
COOL – Select lowest possible temperature
HEAT – Select highest possible temperature
Let each function run for 5 minutes, and perform the following
checks:
Before teSt run
teSt run inStructionS
1
2
3
4
List of Checks to Perform
PASS/FAIL
No electrical leakage
Unit is properly grounded
All electrical terminals
properly covered
Indoor and outdoor units
are solidly installed
All pipe connection
points do not leak
Outdoor
(2):
Indoor
(2):
Water drains properly from
drain hose
All piping is properly insulated
Unit performs COOL
function properly
Unit performs HEAT
function properly
Indoor unit louvers rotate properly
Indoor unit responds to
remote controller