SPLIT-TYPE ROOM AIR CONDITIONER
WARNING
WARNING
BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN
OFF THE MAIN POWER TO THE SYSTEM.
ALL WIRING MUST PERFORMED STRICTLY IN ACCORDANCE WITH
THE WIRING DIAGRAM LOCATED INSIDE THE OUTDOOR UNIT S
WIRE COVER.
Prepare the cable for connection:
USE THE RIGHT CABLE
Indoor Power Cable (if applicable): H05VV-F or H05V2V2-F
Outdoor Power Cable: H07RN-F
Signal Cable: H07RN-F
Using wire strippers, strip the rubber jacket from both ends of
cable to reveal about 15cm (6in) of the wires inside.
Strip the insulation from the ends of the wires.
Using a wire crimper, crimp u-lugs on the ends of the wires.
PAY ATTENTION TO LIVE WIRE
While crimping wires, make sure you clearly distinguish the Live
(“L”) Wire from other wires.
Unscrew the electrical wiring cover and remove it.
Unscrew the cable clamp below the terminal block and place
it to the side.
Match the wire colors/labels with the labels on the terminal
block, and firmly screw the u-lug of each wire to its
corresponding terminal.
After checking to make sure every connection is secure, loop
the wires around to prevent rain water from flowing into the
terminal.
Using the cable clamp, fasten the cable to the unit. Screw the
cable clamp down tightly.
Insulate unused wires with PVC electrical tape. Arrange them
so that they do not touch any electrical or metal parts.
Replace the wire cover on the side of the unit, and screw it
in place.
2
3
4
5
6
7
8