20
EDEM
SPLIT-TYPE ROOM AIR CONDITIONER
If allowed, you can install the wall-mounted unit with rubber
gaskets to reduce vibrations and noise.
to reduce viBrationS of Wall- mounted unit
1
2
3
4
5
6
7
8
Before installing a wall-mounted unit, make sure that the wall
is made of solid brick, concrete, or of similarly strong material.
The wall must be able to support at least four times the weight
of the unit.
Step 4: Connect signal and power cables
The outside unit’s terminal block is protected by an electrical
wiring cover on the side of the unit.
A comprehensive wiring diagram is printed on the inside of the
wiring cover.
Mark the position of bracket holes based on dimensions in the Unit
Mounting Dimensions chart.
Pre-drill the holes for the expansion bolts.
Clean dust and debris away from holes.
Place a washer and nut on the end of each expansion bolt.
Thread expansion bolts through holes in mounting brackets, put
mounting brackets in position, and hammer expansion bolts into
the wall.
Check that the mounting brackets are level.
Carefully lift unit and place its mounting feet on brackets.
Bolt the unit firmly to the brackets.
If you will install the unit on a wall-mounted bracket, do the
following:
CAUTION
Remove the electrical control board cover from the outdoor
unit by loosening the screw.
Connect the connective cables to the terminals as identified
with their respective matched numbers on the terminal block
of indoor and outdoor units.
Secure the cable onto the control board with the cord clamp.
To prevent the ingress of water, form a loop of the connective
cable as illustrated in the installation diagram of indoor and
outdoor units.
Insulate unused cords (conductors) with PVC-tape. Process
them so they do not touch any electrical or metal parts.
1
2
3
4
5
CONNECT THE CABLE TO THE OUTDOOR UNIT
Содержание EDEM