20
ECOWATER
S
Y
S
T
E
M
S
Faceplate Controller, Features/Options
Primary Menu, continued
Water Flow Rate: Enter Primary Menu. Press the (
↑
) or (
↓
) keypads until cursor
is next to Water Flow Rate. Press the SELECT/EXIT (
↵
) keypad. When se-
lected, this screen will show the water flow rate in liters per minute (LPM) or gal-
lons per minute (GPM) with the moving bar graph at the bottom of the display.
Water Used Today: Enter Primary Menu. Press the (
↑
) or (
↓
) keypads until cur-
sor is next to Water Used Today. Press the SELECT/EXIT (
↵
) keypad and the
liters/gallons used since midnight will be shown in the display.
Average Water Use: Enter Primary Menu. Press the (
↑
) or (
↓
) keypads until cur-
sor is next to Average Water Use. Press the SELECT/EXIT (
↵
) keypad and the
average liters/gallons use each day will be shown in the display.
Soft Water Meter: Enter Primary Menu. Press the (
↑
) or (
↓
) keypads until cursor
is next to Soft Water Meter. Press the SELECT/EXIT (
↵
) keypad. This screen
is similar to a trip odometer in that it will count the number of liters/gallons through
the system until it is reset. To reset back to zero press the (
↓
) keypad.
Set Rolling Screen: Enter Primary Menu. Press the (
↑
) or (
↓
) keypads until cur-
sor is next to Set Rolling Screen. Press the SELECT/EXIT (
↵
) keypad. This
menu will disable the Normal Screen Views from scrolling and will show only the
screen that is most current.
Set 12/24 Hour Clock: Enter Primary Menu. Press the (
↑
) or (
↓
) keypads until
cursor is next to Set 12/24 Hour Clock. Press the SELECT/EXIT (
↵
) keypad.
Moving the (
↑
) or (
↓
) keypads will change clock display from 12 hour (AM & PM)
or 24 hour format.
Set Gallons/Liters: Enter Primary Menu. Press the (
↑
) or (
↓
) keypads until cur-
sor is next to Set Gallons/Liters. Press the SELECT/EXIT (
↵
) keypad. Moving
the (
↑
) or (
↓
) keypads will change displays to indicate water in gallons or liters.
Set Grains/PPM: Enter Primary Menu. Press the (
↑
) or (
↓
) keypads until cursor
is next to Set Grains/PPM. Press the SELECT/EXIT (
↵
) keypad. Change be-
tween diplaying hardness units in grains or parts per million (PPM). Note: 1 gpg
= 0.959
_
d = 1.71
_
F = 17.1 ppm
continued