INSTRUCTIONS MANUAL
-101-
DATA
This menu shows all data read by the machine. From the MAIN MENU:
P
ress “i” key
, the following screen will be displayed:
SW V.: Software version
Tank refrigerant:
o
Total: total amount of refrigerant in the storage bottle.
o
Available: quantity of refrigerant available in the storage bottle.
o
Pressure: refrigerant storage bottle pressure.
o
Temperature: refrigerant storage bottle temperature.
PAG: quantity of PAG OIL in the container.
POE: quantity of POE OIL in the container.
UV H: quantity of DYE in the container.
USED OIL: quantity of OIL in the USED OIL container.
A/C : pressure in the service hoses.
EV: pressure in the evaporator.
EXT: ambient temperature near the service station.
Service alarm
performed.
Change analyzer performed.
Press
to return to MAIN MENU.
DD/MM/YY XX:XX PM
ECK
FLAG
MAIN MENU
TANK PRESSURE
PAG
6.32 BAR
136ml
TANK TEMPERATURE
POE
17.9°C
110 ml
REFRIGERANT AVAILABLE UV H
2735 g
27ml
USED OIL
89 ml
DD/MM/YY XX:XX PM
INFO
TANK REFRIGERANT
Total
Pressure
xxxx g
x.xx bar
Available
Temperature
xxxx g
xx.x °C
A/C
EV
EXT
xx.xx bar
xx.xx bar
xx.x °C
PAG
POE
UV H USED OIL
XXX ml
XXX ml
XXX ml XXX ml
DB neuma.023.56.73_27
SN: TC2500277
CHANGE ANALYSER FILTER
SERVICE
FW 0.49 Feb 14 2019
SW eckFlag21p2
Содержание ECK FLAG
Страница 1: ......
Страница 23: ...INSTRUCTIONS MANUAL 24 FIG 8 p 9 g 8 FIG 9 s v u i w t...
Страница 24: ...INSTRUCTIONS MANUAL 25 l FIG 10 k c d e 1 b f j v q r x...
Страница 25: ...INSTRUCTIONS MANUAL 26 FIG 11 n o 2 m a y z...
Страница 26: ...INSTRUCTIONS MANUAL 27 FIG 12 4 3 6 5 h 7...
Страница 101: ...INSTRUCTIONS MANUAL 102 CODES SUMMARY OPTION code 43210791...
Страница 102: ...MANUEL D INSTRUCTIONS 2...