Press
to continue.
the machine will recover all the refrigerant into the service hoses; then the machine will sound
and alarm and the following screen will be displayed:
Press
to return to the MAINTENANCE MENU; EMPTY HOSES is now successfully
completed.
SERVICES ALARM
Replace the filter whenever the machine gives the service alarm signals the presence of
humidity in the circuit.
Before performing any operation, check that the replacement filter is the same type as these
installed on the machine.
Then proceed as described below:
1)
Wear protective gloves and glasses
2) Connect the machine to the electrical supply and it turn on
3) Note down the release code on the new filters.
IMPORTANT: Filter replacement must be performed as quickly as possible in order
to avoid possible contamination by moisture in the ambient air.
NOTE: If possible, check the seal on the couplings of the new filter, using an electronic leak
tester.
4) From MAINTENANCE, select SERVICES ALARM, the following warning message is
visualized:
Empty hoses
DD/MM/YY XX:XX PM
MAINTENANCE / EMPTY HOSES
Hoses pressure
4.01 bar
EMPTY HOSES COMPLETED
DD/MM/YY XX:XX PM
MAINTENANCE / EMPTY HOSES