INSTRUCTIONS MANUAL
-36-
START AUTOMATIC PROCEDURE:
If gas analyzer is installed, The machine will test the purity of the refrigerant gas in the A/C
system before beginning recovery (refer to Gas analyzer instruction manual)
Connect and open HP and LP couplings (or those chosen in the previous point)
to A/C system and press
to continue
the AUTOMATIC PROCEDURE will start, and the following screen will be displayed:
The machine will continue automatically
During the recovery phase, the machine displays the quantity of refrigerant recovered, in
grams. Upon completion of recovery, the machine will stop and discharge, while automatically
displaying the used oil extracted from the A/C system during the recovery phase.
The oil discharge operation lasts 4 minutes.
Connect and open HP and LP couplings
To A/C system and press to continue
DD/MM/YY XX:XX PM
AUTOMATIC / RECOVERY
Please wait …
DD/MM/YY XX:XX PM
AUTOMATIC / RECOVERY
Refrigerant recovered
0 g
Oil recovered
0 ml
A/C pressure
6.31 bar
Tank pressure
6.71 bar
Tank temperature
22.0°C
Refrigerant recovery
DD/MM/YY XX:XX PM
AUTOMATIC / RECOVERY
Refrigerant recovered
120 g
Oil recovered
0 ml
A/C pressure
2 bar
Tank pressure
6.71 bar
Tank temperature
22.0°C
Oil recovery
DD/MM/YY XX:XX PM
AUTOMATIC / RECOVERY
Refrigerant recovered
500 g
Oil recovered
10 ml
A/C pressure
0 bar
Tank pressure
6.81 bar
Tank temperature
22.0°C
Содержание ECK FLAG
Страница 1: ......
Страница 23: ...INSTRUCTIONS MANUAL 24 FIG 8 p 9 g 8 FIG 9 s v u i w t...
Страница 24: ...INSTRUCTIONS MANUAL 25 l FIG 10 k c d e 1 b f j v q r x...
Страница 25: ...INSTRUCTIONS MANUAL 26 FIG 11 n o 2 m a y z...
Страница 26: ...INSTRUCTIONS MANUAL 27 FIG 12 4 3 6 5 h 7...
Страница 101: ...INSTRUCTIONS MANUAL 102 CODES SUMMARY OPTION code 43210791...
Страница 102: ...MANUEL D INSTRUCTIONS 2...