6
WATER SPECIALIST DISC VALVE PROGRAMMING AND SERVICE MANUAL
The control valve offers multiple procedures that allow the valve to be modifi ed to suit the needs of
the installation. These procedures are:
• OEM System Setup
• Installer Displays & Settings
• User Displays
These procedures can be accessed in any order. Details on each of the procedures are provided
below and on the following pages.
When in operation, normal user displays show the time of day or days remaining before regeneration.
When stepping through a procedure, if no buttons are pressed within fi ve minutes the display returns
to a normal user display. Any changes made prior to the five minute time out are incorporated.
To reinitialize the control valve, check to make sure the control is in the User Display. Then
simultaneously press NEXT and REGEN or unplug power source plug on the circuit board, wait
approximately 3 seconds and plug back in.
3. BUTTON OPERATION AND FUNCTION
or
UP or DOWN
Either button changes the value of the setting being viewed
NEXT
1. Moves to the next display
2.
While viewing Time of Day, press and hold for 3 seconds to
change the time of day
REGEN
1.
Toggles a manually initiated delayed regeneration on or off
2.
Holding for more than 3 seconds forces an immediate
regeneration
3.
Moves back one display while in programming mode
4. Pressing during regeneration immediately advances the
valve to the next regeneration cycle step
and
Re-homes valve, displays the software version, and resets a
manually initiated regeneration request
Key sequence to lock and unlock software. With software
locked, USER and INSTALLER levels may still be viewed and
set as desired.
2. OEM GENERAL INSTRUCTIONS