WATER SPECIALIST DISC VALVE PROGRAMMING AND SERVICE MANUAL
5. SETTING OPTIONS TABLE
System
Type
Regeneration
Option
Capacity
Day
Over-ride
Soft
RES
0.10-200 kg
1-28 days
Regeneration occurs at the next
regeneration time when volume capacity
falls below the reserve capacity, or the
specified number of days is reached,
whichever comes first
Soft
RES
0.10-200 kg
OFF
Regeneration occurs at the next
regeneration time when volume capacity
falls below the reserve capacity
Soft
Delayed
.02-5700 m
3
1-28 days
Regeneration occurs at the next
regeneration time when volume capacity
reaches 0, or the specified number of days
is reached, whichever comes first
Soft
Delayed
.02-5700 m
3
OFF
Regeneration occurs at the next
regeneration time when volume capacity
reaches 0
Soft
Delayed
OFF
1-28 days
Time Clock operation.
Regeneration occurs at the next
regeneration time the specified number of
days is reached.
Soft
On 0
.02-5700 m
3
1-28 days
Regeneration occurs immediately when
volume capacity reaches 0, or the
specified number of days is reached,
whichever comes first
Soft
On 0
.02-5700 m
3
OFF
Regeneration occurs immediately when
volume capacity reaches 0
FLT1
Delayed
.02-5700 m
3
1-28 days
Regeneration occurs at the next
regeneration time when volume capacity
reaches 0, or the specified number of days
is reached, whichever comes first
FLT1
On 0
.02-5700 m
3
OFF
Regeneration occurs immediately when
volume capacity reaches 0
FLT2
Delayed
.02-5700 m
3
1-28 days
Regeneration occurs at the next
regeneration time when volume capacity
reaches 0, or the specified number of days
is reached, whichever comes first
FLT2
On 0
.02-5700 m
3
OFF
Regeneration occurs immediately when
volume capacity reaches 0