9. OEM INSTALLER SETTINGS
STEP 1I
STEP 1I
– From normal mode, press UP and NEXT
simultaneously for about 3 seconds and release.
STEP 2I
STEP 2I
– Inlet Water Hardness (PPM) - Set the amount
of infl uent hardness using UP or DOWN. Press NEXT
to go to Step 3I. Press REGEN to exit OEM Installer
Settings.
This screen will only be displayed when “rES” is selected
in step 3S.
STEP 3I
STEP 3I
– Service Water Hardness (PPM) - If a mixing
valve is installed in the valve, service hardness needs to
be set. Setting range is always less than the setting in
Step 2I. This screen will only be displayed when ‘rES’ is
selected in Step 3S.
Press NEXT to go to Step 4I. Press REGEN to return to
previous step.
STEP 4I
STEP 4I
– Day Override - Adjust day override from 1 - 28
days or OFF using UP or DOWN. Press NEXT to go to
Step 5I. Press REGEN to return to previous step.
STEP 5I
STEP 5I
– Time of Regeneration, Hour - Set the time
(hour) for regeneration using UP or DOWN. The default
time is 2:00 a.m. This display will show “on 0” if “on 0” is
selected in Step 3S. Press NEXT to go to Step 6I. Press
REGEN to return to previous step.
STEP 6I
STEP 6I
– Time of Regeneration, Minutes - Set the time
(minutes) for regeneration using UP or DOWN. The
default time is 2:00 a.m. This display will not appear if
“on 0” is selected in Step 3S. Press NEXT to exit Installer
Settings. Press REGEN to return to previous step.
RETURN TO
NORMAL MODE