2. SPECIFICATIONS AND COMPONENTS

2.1. MODEL DESIGNATIONS

Models                                                                   Model of your system

1

 — The type of filter. RO stands for reverse osmosis.

2

 — Number of stages. 

— Capacity of reverse osmosis membrane in GPD (gallons per day)*:

*Capacity of the reverse osmosis filter is variable and depends on a number of factors. These include supply water quality,   

wear of pre-filter cartridges and of membrane itself, supply water pressure and temperature.

4

 — Legend of additional equipment (no letters specify base model with no extra equipment):

For example:

 Ecosoft 

R

O775MUVP means reverse osmosis unit with 7 stages equipped with 

membrane of 75 gallon per day capacity (11.6 l / h), mineralizing post-filter, UV lamp, and booster 

pump.

CAUTION! 

Filter installation should be carried out by a specialist with appropriate qualifications and 

experi

ence.

The product should only be used with cold water supply!

R

O 5-36(50,75,100)

R

O 5-36(50,75,100)P

R

O 6-36(50,75,100)M

R

O 6-36(50,75,100)MP

R

O 6-36(50,75,100)UV

R

O 6-36(50,75,100)UVP

R

O 7-36(50,75,100)MUV

R

O 7-36(50,75,100)MUVP

36GPD

136 liters per day

5.6 liters per hour

50GPD

190 liters per day

7.9 liters per hour

75GPD

280 liters per day

11.6  liters per hour

100GPD

380 liters per day

15.8 liters per hour

R

O   * - ***     ****    

  1      2    3         4    

M

The filter is equipped with mineralizing post-filter

P

The filter is equipped with pressure booster pump

UV

The filter is equipped with ultraviolet disinfection unit

Содержание RO 5-100

Страница 1: ...Installer and user guide for domestic reverse osmosis system Einbau und Bedienungsanleitung f r Umkehrsosmose Haushaltssysteme Manual privind conectarea i exploatarea sistemului de osmoz invers...

Страница 2: ...2...

Страница 3: ...neralizing post filter with double lever faucet 19 3 7 Connection diagram for unit with booster pump and ultraviolet lamp 17 3 8 Connection diagram for unit with booster pump ultraviolet lamp and mine...

Страница 4: ...er rack is connected to cold water supply with feed water adapter 4 and feed valve 5 Red tube carries water from feed valve to the rightmost bulb filter rack Incoming water then passes through pre fil...

Страница 5: ...fill empty tank can range from 1 5 to 3 hours After the tank has been filled the auto shut off valve shuts off the water supply from the pre filters and the unit stops After opening purified water fau...

Страница 6: ...Ecosoft RO775MUVP means reverse osmosis unit with 7 stages equipped with membrane of 75 gallon per day capacity 11 6 l h mineralizing post filter UV lamp and booster pump CAUTION Filter installation...

Страница 7: ...s not recommended If water supply does not meet the requirements service life of membrane and or pre filter cartridges may be shortened If your home is supplied with raw wellwater perform laboratory t...

Страница 8: ...REVERSE OSMOSIS SYSTEM COMPONENTS The manufacturer reserves the right to modify product design or specific components if such modification does not entail deterioration of consumer properties of the p...

Страница 9: ...d water adapter 8 Drain saddle 5 Feed valve 3 Drinking water faucet 7 Set of colored tubes 4 pieces 9 Set of pre filter cartridges may vary with model 12 Flow restrictor inserted in black tube 13 Lock...

Страница 10: ...AND USER GUIDE 3 CONNECTION DIAGRAMS 3 1 CONNECTION DIAGRAM FOR BASE MODEL The manufacturer reserves the right to modify product design or specific components if such modification does not entail dete...

Страница 11: ...GUIDE 3 CONNECTION DIAGRAMS 3 2 CONNECTION DIAGRAM FOR UNIT WITH MINERALIZING POST FILTER The manufacturer reserves the right to modify product design or specific components if such modification does...

Страница 12: ...3 CONNECTION DIAGRAMS 3 3 CONNECTION DIAGRAM FOR UNIT WITH ULTRAVIOLET LAMP The manufacturer reserves the right to modify product design or specific components if such modification does not entail de...

Страница 13: ...R GUIDE 3 CONNECTION DIAGRAMS 3 4 CONNECTION DIAGRAM FOR UNIT WITH BOOSTER PUMP The manufacturer reserves the right to modify product design or specific components if such modification does not entail...

Страница 14: ...DIAGRAMS 3 5 CONNECTION DIAGRAM FOR UNIT WITH BOOSTER PUMP AND MINERALIZING POST FILTER The manufacturer reserves the right to modify product design or specific components if such modification does n...

Страница 15: ...CONNECTION DIAGRAM FOR UNIT WITH ULTRAVIOLET LAMP AND MINERALIZING POST FILTER WITH SINGLE LEVER FAUCET The manufacturer reserves the right to modify product design or specific components if such mod...

Страница 16: ...AND MINERALIZING POST FILTER WITH DOUBLE LEVER FAUCET The manufacturer reserves the right to modify product design or specific components if such modification does not entail deterioration of consumer...

Страница 17: ...ION DIAGRAMS 3 7 CONNECTION DIAGRAM FOR UNIT WITH BOOSTER PUMP AND ULTRAVIOLET LAMP The manufacturer reserves the right to modify product design or specific components if such modification does not en...

Страница 18: ...AGRAM FOR UNIT WITH BOOSTER PUMP ULTRAVIOLET LAMP AND MINERALIZING POST FILTER WITH SINGLE LEVER FAUCET The manufacturer reserves the right to modify product design or specific components if such modi...

Страница 19: ...LAMP AND MINERALIZING POST FILTER WITH DOUBLE LEVER FAUCET The manufacturer reserves the right to modify product design or specific components if such modification does not entail deterioration of co...

Страница 20: ...the presence of residual water is allowed Wash your hands thoroughly with anti bacterial soap before handling tubes cartridges and membrane This system should desirably be installed in places protecte...

Страница 21: ...dle is compatible with most standard drain pipes Drill a hole of 5 0 mm diameter in the kitchen sink drain pipe apply rubber gas ket with sticky base included in the package Install the drain saddle 8...

Страница 22: ...the faucet s shank ensuring the compression ring is in the joint Screw on the compression nut in order to join the tube to the faucet Installation of the double lever faucet for a system with mineral...

Страница 23: ...e housing CAUTION Cut the plastic bag to install the reverse osmosis membrane Install the membrane without first unpacking it by pushing it into the housing directly from the bag Avoid touching the me...

Страница 24: ...ater and TDS of purified water using a calibrated TDS meter 4 Check if the auto shut off valve functions properly Close tank valve 6 and faucet 3 The unit must stop operating water should stop being d...

Страница 25: ...roughly with water Insert the new cartridges in the first and second sumps by water flow direction Disconnect the tube stemming from the third sump from the auto shut off valve 8 Open the feed valve 5...

Страница 26: ...lled with water Remove the used filter cartridge and wash the sump with unflavored soap and a clean sponge then rinse thoroughly with water Insert new cartridge into the third sump Screw the sump back...

Страница 27: ...f the tube CAUTION Cut the plastic bag to install the reverse osmosis membrane Install the membrane without first unpack ing it by pushing it into the housing directly from the bag Avoid touching the...

Страница 28: ...et 3 so that the tank starts to re fill Depending on the pressure in your water mains filling may take 1 5 to 3 hours After the second tank re fill you can safely use the purified water 6 4 THE PROCED...

Страница 29: ...UV lamp from the power supply 2 Shut off the feed valve 5 and tank valve 6 3 4 5 6 7 8 Remove the black PVC end cap with wire hole Remove the lamp from the quartz sleeve by pulling on its base Do NOT...

Страница 30: ...desirable to sanitize the system when replacing cartridges Using chlorine disinfectant tablets is recommended for reverse osmosis filter sanitization 1 Shut off feed valve 5 and tank valve 6 2 Remove...

Страница 31: ...15 minutes open the drinking water faucet 3 and feed valve 5 7 When water running from the faucet 3 starts to smell like chlorine close both the faucet 3 and feed valve 5 8 Leave the system for 2 3 h...

Страница 32: ...SYSTEM INSTALLER AND USER GUIDE 7 SANITIZATION OF REVERSE OSMOSIS FILTER 1 Turn off feed valve 5 2 Open the faucet 3 and empty the pressure tank in the drain 3 Shut tank valve 6 4 Extract pre filter...

Страница 33: ...ew on 8 After 15 minutes open tank valve 6 9 Open the feed valve 5 for 5 minutes 10 Close the tank valve 6 and leave the tank filled with chlorine solution for 1 2 hours 11 Open tank valve 6 and drain...

Страница 34: ...ly If necessary install a pressure booster pump or consult a plumber Pre filter cartridges are clogged Replace pre filter cartridges Membrane is clogged Measure permeate flowrate by closing tank valve...

Страница 35: ...If it faces drain saddle fitting clean it and swap ends of the tube so that it is placed at the outlet of membrane housing If flow restrictor was not installed install one Failure of auto shut off val...

Страница 36: ...t filter Preservative solution in the membrane has not been flushed out Drain all the water from the tank and let the system re fill it Contamination in reverse osmosis system Sanitize the system per...

Страница 37: ...MISSIONING Installation works were completed The product was tested and is fully functional No claims as to product quality and or installer s performance were encountered Owner_______________________...

Страница 38: ...E 9 SERVICE RECORD MAINTENANCE LOG Type of job Consumables used for the job product date of manufacture serial number example cartridges membrane Sanitization performed YES NO Tank fill duration HH MM...

Страница 39: ...ing at ambient tem peratures ranging from 5 C to 40 C and relative humidity up to 80 at least 1 m away from heating equipment We thank you for purchasing a reverse osmosis product by Ecosoft Company W...

Страница 40: ...ack of voltage regulator where it is required components that require replacement because of normal wear and tear faults and problems that have arisen due to untimely replacement of consumable element...

Страница 41: ...40 41 This manual is the intellectual property of Ecosoft Copying and reprinting is prohibited 2014 ENG REVERSE OSMOSIS SYSTEM INSTALLER AND USER GUIDE NOTES...

Страница 42: ...42 42 This manual is the intellectual property of Ecosoft Copying and reprinting is prohibited 2014 REVERSE OSMOSIS SYSTEM INSTALLER AND USER GUIDE NOTES 42...

Отзывы: