9.
10.
11.
Remove the third pre-filter’s sump from filter head. Be careful as it is filled with water.
Remove the used filter cartridge and wash the sump with unflavored soap and a clean sponge, then rinse thoroughly
with water.
Insert new cartridge into the third sump. Screw the sump back on and let through at least 4 more liters of water to
flush the coal dust. Close the feed valve
5
and connect the previously separated tube with the auto shut-off valve.
13.
Open the tank valve
6
.
14.
Open the feed valve
5
.
6.
USAGE