REVERSE OSMOSIS SYSTEM INSTALLER AND USER GUIDE
6.
USAGE
Use care when removing sealing rings from the ends of the sleeve. The rings serve to protect the
lamp and electrical connections from water leaks.
UV lamps should be handled with care and only held by the ceramic ends, because contaminat-
ing the quartz surface will reduce germicidal efficiency and shorten service life. Use cotton gloves
while handling UV lamps.
1.
Disconnect the UV lamp from the power supply.
2.
Shut off the feed valve
5
and tank valve
6
.
3.
4.
5.
6.
7.
8.
Remove the black PVC end cap with wire hole.
Remove the lamp from the quartz sleeve by pulling on its base.
Do NOT touch the bulb!
Disconnect the power connector holding the lamp by its base.
Insert the new lamp half way into the quartz sleeve.
Properly connect the power connector.
Push the new lamp all the way into the housing and put the
PVC cap on its end.
9.
Restore the water supply to the unit and check if tightness of quartz sleeve sealing has not been disrupted during lamp
replacement.
10.
Plug UV lamp adapter in a socket and verify that the new UV lamp is functioning properly. This will be confirmed by
continuous green LED light on the adapter.