REVERSE OSMOSIS SYSTEM INSTALLER AND USER GUIDE
6.
USAGE
1.
Turn off water supply to the system (feed valve
5
), shut off the tank valve
6
.
2.
Open the purified water faucet
3
to relieve permeate pressure.
3.
4.
5.
6.
7.
Disconnect the tubes that connect the carbon post filter / mineralizing
post-filter to the rest of the system (remember which goes where).
Remove the used carbon post-filter / mineralizing post-filter from clip
brackets.
Install new carbon post-filter / mineralizing post-filter, guided by arrows
that indicate the direction of water flow.
Connect the tubes to the new carbon post-filter / mineralizing post-fil-
ter to connect it to the system.
Open feed valve
5
. Open tank valve
6
.
9.
Once the tank is full (you will hear the water stop flowing), drain all water from the tank into the sink by opening
faucet
3
. When the water stops running, close the purified water faucet
3
so that the tank starts to re-fill.
Depending on the pressure in your water mains, filling may take 1.5 to 3 hours. After the second tank re-fill, you can safely
use the purified water.
6.4 THE PROCEDURE FOR REPLACING CARBON POST-FILTER AND/OR
MINERALIZING POST-FILTER
6.5 THE PROCEDURE FOR REPLACING UV LAMP
(UV lamp replacement should be performed by a qualified specialist)
Recommended life of the UV lamp is 9000 hours (approximately 1 year of continuous operation).
CAUTION!
Using UV lamp beyond the recommended service life is disapproved, since the intensity of UV
radiation and its germicidal efficiency will be reduced.
It is strongly forbidden to turn on the UV lamp power when the lamp is not in metal housing, and
to look at a glowing lamp. This can lead to eye damage and result in deterioration or loss of vision.
When replacing the UV lamp, it is advisable to clean the quartz sleeve. Do not use abrasive mate-
rials to clean the sleeve, as this may decrease transparency of the sleeve to UV radiation, thereby
reducing the efficiency of disinfection. Be careful when removing the quartz sleeve from the housing
to avoid damaging or scratching the sleeve.