www.ecosmartfire.com
english
Please read these instructions completely before operating the
ecoSmart™ Fire.
these models are suitable for use both indoors and outdoors.
there are no requirements for side and/or overhead clearances as
spacers are part of the design.
the firebox cavity should include a layer of cement sheeting prior to
inserting the firebox to limit heat transference. missing heat insulation
can cause overheating, which may result in damages to the material
surrounding the firebox.
do not PacK reQuired air sPaces (the sPace between
the firebox and the sPacer) with insulation or other
materials. the air sPaces are needed for ProPer
Ventilation of the burner.
WARNING: Ensure that your fire is positioned away from flammable
materials and other sources of ignition at all times. Pay very close
attention to positioning the fire away from items that may move as
a result of wind and drafts. For example trees/branches/curtains/
paper and the like.
note: stainless steel will rust or corrode over time if contamination
or debris is not cleaned or removed immediately. when not in use, it
is recommended that you protect your fireplace from water damage
or corrosion with a protective cover and always use the burner lid
included with your model to safeguard the burner.
CV Firebox Inserts
Clearances
CV Firebox Inserts
Installation
The zero clearance firebox inserts are designed for installation into a
wall or cavity made from combustible or non-combustible materials.
They are engineered specifically to accept EcoSmart Fire Burners.
Fireboxes must be installed into a fixed secure position before being
operated. They can be fitted from either the front side of the flange
or from the back of the flange (screwed, riveted or glued with a high
temperature resistant bonding product) onto the surrounding structural
framework.
The floor must be level and the Firebox positioned on a flat surface.
The firebox must be installed in a setting that is built to safely hold the
weight of the model. In the case of insufficient capacity to hold the
weight of the model, measures must be taken to reinforce the setting
(for example installation of a plate for load distribution) so that the
setting is suitable for installation.
NotICe: do Not INStAll dIReCtlY beSIde oR NeAR
WAllPAPeR, lAMINAte, VeNeeR oR ANY SURFACe tHAt
HAS NOT BEEN FIRE RATED (the heat will impact the material,
and in some circumstances the glue used for its application).
tHIS INClUdeS tHe detAIlING/FINISHING MAteRIAlS USed
oN tHe deCoRAtIVe SURFACeS ARoUNd tHe INStAlled
FIRebox. ReFeR to tHe PRodUCt SPeCIFICAtIoN oF tHe
WAllPAPeR, lAMINAte, VeNeeR, GlUe oR otHeR beING USed
ARoUNd tHe INStAllAtIoN to eNSURe HeAt toleRANCeS
ARe CoMPAtIble. WHeN tHe APPARAtUS IS IN oPeRAtIoN
tHe AReA ARoUNd tHe Model GetS Hot - HeAt SeNSItIVe/
ReACtIVe MAteRIAlS SHoUld Not be USed. do Not PlACe
FlAMMAble obJeCtS oN oR ARoUNd tHe APPARAtUS.
fireboxes are not designed to incorporate doors or opening covers (unless
specifically purchased as a resolved item from MAD Design Group).
the firebox must remain open at all times for ventilation – it is not
designed to operate as an oven or similar “hot box” – the flame must
have a constant supply of air to operate and be able to circulate and
distribute the heat effectively.