Maintenance

Heat pump water heater is a high automatic equipment, please perform regular inspection

termly. If the unit can be long-term and efficiently maintenance, the operating reliability

and service life will have an unexpected increase.

1.The extra water filters should be cleaned regularly to ensure clean water quality of the

   system,  and to avoid damage caused by dirty water filter blocking.

2.Users should pay attention for usage and maintenance to below : all units' protection

   devices are set up before leaving factory, do not make any adjustment by yourself.

3.Frequently check the power supply and electrical wiring system is solid or not, whether

   electrical components are abnormally working, if yes, should timely maintenance and

   change for a new one.

4.Perform regular checks of the water supply system, check whether the tank safety valve,

   liquid level controller and exhaust devices work properly, so as to avoid air into the system,

   and reduce the water cycle volume, thus affect the heating function and operation reliability.

5.Check whether pumps and water valves are normal working or not, whether water tubing

   and water pipes connector are leakage or not.

6.The unit and around should remain clean, well-ventilated. Regularly clean (1-2 month)the

   side air heat exchanger to maintain a good effect of heat exchange.

7.Frequently check whether each part of the unit work  normal or not, check whether there is

   oil on the pipeline joints and  charging valve  to ensure that no refrigerant leakage.

8.Do not piling up debris around the unit, so as not to block from air inlet and outlet, the unit

   around should be kept clean the dry, well-ventilated.

9.If the unit stops for a longer time, should drain all the water in the pipeline, cut off power

   supply, and sets the protective equipment.When re-run the unit, complete inspection is a

   must before reboot.

10.When unit failure, and the user can not resolve the problem, please call our Company in

   local maintenance department, in order to promptly send people for maintenance.

11.Host condenser cleaning.We propose to use 50

-60

, and 15% hot phosphoric acid for

   condenser cleaning, launch the  circulating pump of the host unit for three hours'  cleaning,

   finally rinse with water three times. (Propose to back up a 3-way connector when installing

   the pipeline, block one joint),in order to clear the connection pipe. Do not use corrosive

   cleaning fluid for condenser cleaning.

12.Water tanks need to remove theWater scale after some time (normally two months,

   according to the water quality of local place).

.Maintenance

Water heater

20

Содержание SWBM-10.5H-B/P-S

Страница 1: ...Installation Instruction Manual LOW AMBIENT HEAT PUMP WATER HEATER MODEL SWBM 10 5H B P S SWBM 17 5H B P S SWBM 35 0H B S...

Страница 2: ......

Страница 3: ...customers Product Introducing 2 Work principle 3 Performance Data 4 Dimension 5 Operation introductions 8 Wire Circuit Diagram 14 Installation instructions 16 Maintenance 20 1 CONTENTS Water heater C...

Страница 4: ...omponents without switching off the electrical supply to the unit Electric leakage switch protection device MUST be installed 3 It is forbidden to start any work on the electrical components if water...

Страница 5: ...Heat pump not only use less electricity to get heat from ambient air but are also able to combine using with solar equipment will not cause pollution and no poison gas exhausting All Round The Year Ho...

Страница 6: ...mpressor compress it the refrigerant gas became high temperature and high pressure Then the gas come into the water condensation into liquid emit a lot of condensation heat condensing heat absorbed by...

Страница 7: ...et Weight Gross Weight Unit Dimension L W H Weight kg Kpa Water pump Power Head M KW RPM dB A inch 3 m h mm mm W V PH Hz COP W W Running Current Heating A Heating Input Power W Scroll SWBM 17 5H B P S...

Страница 8: ...Water heater Dimension Measure mm The dimension for air source heat pump water heater SWBM 10 5H B P S 5 804 1510 1362 565 460 420 500...

Страница 9: ...Measure mm The dimension for air source heat pump water heater SWBM 17 5H B P S low ambient Dimension Water heater 6 1300 765 420 1370 460 500...

Страница 10: ...The dimension for low ambient air source heat pump water heater SWBM 35 0H B S Dimension Water heater Measure mm 7 1850 1580 508 1790 880 460 500...

Страница 11: ...ss to turn on or turn off the heat pump 2 1 2 After entering parameter or clock setting press once to return to main interface Start up state Stand by state 1 2 Initialization Operation introductions...

Страница 12: ...d keyboard is locked 3 2 2 Under locked state press both and at the same time for 5 seconds after Dee sound keyboard is unlocked heat pu Clock setting 3 3 Clock Setting 3 3 1 On main interface press o...

Страница 13: ...n minute 3 4 4 After setting the minutes press once to confirm and save all the Timer On setting and switch to Timer Off setting interface At this moment the hour of clock shows and flashes press or t...

Страница 14: ...31 32 Display also even system is not start up Actual testing value Actual testing value Actual testing value Actual testing value Actual testing value Actual testing value Actual testing value Actual...

Страница 15: ...or failure Ambient 12 System parameter setting 3 5 2 On the interface of Parameter and Status inquiry if not pressing any button within 10 seconds system automatically exit the inquiry interface and r...

Страница 16: ...em 1 compressor high pressure failure System 1 compressor low pressure failure System 1 compressor air exhausting temperature too high power phase failure Auxiliary heater temperature too high protect...

Страница 17: ...lve Fan Motor Swichable maghtism valve Wire Controller Transformer U CONTACTOR 1 V W YLW GRN Ambient Temp Economizer inlet Temp Economizer outlet Temp Compressor side air discharge Temp Air fin evapor...

Страница 18: ...er A B C N1 N2 N3 3 High Press Switch SYS1 High Press Switch SYS2 SYS1 Low Press Switch SYS2 Low Press Switch Electric heater protect Water flow Wire Controller C Z 1 C Z 2 C Z 3 C Z 4 C Z 5 C Z 6 C Z...

Страница 19: ...o the distance between the barriers shown in below picture pay attention to arrow direction Water tank 1Water tanks should be placed where ambient temperature is above 0 1Can be installed outdoors or...

Страница 20: ...own on the manual and in accordance with national corresponding construction standards 1Installation of water pipes should be straight and flat pipeline collocation should be rational ensure to minimi...

Страница 21: ...ck the electricity distribution System 1Check if the power supply same as shown on manual and rating label 1Check if all the power supply and control wiring are all well connected check if the wiring...

Страница 22: ...2 minutes 1 When water pump is on and the high level switch cut off if water temperature set Temperature 5 degrees shut down water supply for tanks If water tank temperature temperature 2 degrees the...

Страница 23: ...around should remain clean well ventilated Regularly clean 1 2 month the side air heat exchanger to maintain a good effect of heat exchange 7 Frequently check whether each part of the unit work normal...

Страница 24: ...Air Source Heat Pump Water Heater...

Отзывы: