background image

               

 

- 23 - 

Re-confirm the password the middle two 

A5 

xx 

Re-confirm the password the last two 

A6 

xx 

Maintenance by the default password: 123456, after setting and press "Search" button 

Any change in the password and re-enter the same password and press "Search" button 

to  confirm,  then  the  password  change  successful,  go  to  the  next  menu,  or  modify  the 

invalid, re-display 

A1

items, need to be re-enter. 

Factory password changes 

Factory password changes 

the first two   

A7 

Xx 

Factory password changes 

the middle two 

A8 

Xx 

Factory password changes 

the last two 

A9 

Xx 

Re-confirm the password the first two 

AA 

Xx 

Re-confirm the password the middle two 

Ab 

Xx 

Re-confirm the password the last two 

AC 

Xx 

Protection time 

Ad 

00 

Factory default password: 654321 

After  setting  and  press  "Search"  button,  any  change  in  the  password  and  re-enter  the 

same  password  and  press  "Search"  button  to  confirm,  then  the  password  change 

successful, go to the next menu, or modify the invalid, re-display 

A7

items, need to be 

re-enter. 

The system feature set   

Parameter Name 

Unit No. 

Default 

setting 

01 

O0 

Level Select 

(b1) 

1(0-1) 

yes 

no 

 

(b2) 

1(0-1) 

 

 

 

(b3) 

0(0-1) 

 

 

Содержание CWM Series

Страница 1: ...www econo nl Manual heatpump model Econo CWM...

Страница 2: ...2 1 Specification parameter 4 2 2 The figure of working principle 6 2 3 Figure dimension 7 3 Installation Instruction 6 3 1 Installation 6 3 2 Water system installation chart 11 3 3 Electrical diagra...

Страница 3: ...full consideration of insuring installation as easy as possible Refrigerant circle is a sealed complete system finished by manufacturer No needs for users to connect copper pipes or refrigerant charg...

Страница 4: ...C om pany code D esi gn code P roduct type P roduct desi gn code Picture 1 2 Technical data 2 1 Specification parameter Table 1 Heat pump model CWM 15XB kW 15 0 Rated heating capacity kcal h 12897 Hea...

Страница 5: ...380 3N 50Hz Compressor type Scroll Charged refrigerant R417A 3 Connection pipe RC 32 Noise level dB A 60 W mm 680 D mm 1020 Dimension H mm 770 Net weight kg 180 Enclosure Class IPX4 Date S N See circu...

Страница 6: ...he figure of working principle G r ound souce w at er out l et G r ound sour ce w at er i nl et A C w at er i nl et A C w at er out l et H eat i ng w at er out l et H eat i ng w at er i nl et Picture...

Страница 7: ...ollowing conditions the following conditions the following conditions The selection of installation location The installation location must match the following conditions Make sure the installation en...

Страница 8: ...inage system Picture 4 Attention of moving machine Fork lift stacker or crane is suggested to move the machine The surrounding ambient temperature of unit during transportation must be among 25 to 55...

Страница 9: ...ed at the highest point of hydraulic circle After the hydraulic circle is connected completely exhaust air inside hydraulic circle Drain valve should be installed at the lowest point of water pipe Ple...

Страница 10: ...es are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones...

Страница 11: ...valve 8 Water valve 9 Back valve 10 Y type filter 11 Water tanks 12 Thermometer 13 Flow Control Valve 14Safety valve 15 Pressure switch Hydraulic circle is recommended while installing Water Source H...

Страница 12: ...switch must be installed at the straight pipeline section of the same level from the elbow valves and other pieces of partial resistance to more than 5 times the diameter C The pipe must be insulated...

Страница 13: ...A i r sw i t ch C O M P R S T N N W 1 C C H 1 11 V 1 U 1 K M 1 K M 3 A C w at er pum p K M 4 R L 10 unit wiring Model Power Voltage V Power wire mm2 Allowed max current A Allowed leakage current CWM...

Страница 14: ...1 Seal test to make sure system is well sealed 2 Power source checking to make sure required voltage and current are available 3 Pressure inside hydraulic circle reaches to operating pressure 1 3 kgf...

Страница 15: ...nit Normally the temperature difference should be less than 6 If the temperature difference is over 6 check if water flow match designed standard 7 All hydraulic circle filters must be cleaned after f...

Страница 16: ...en the tank would not compensate water If the tank water temperature is higher than setting value then it would compensate water and the high water level would last pull in water 2 minutes before shut...

Страница 17: ...17 4 Panel operation Settime Time Chec Model Temp Set...

Страница 18: ...geration and heat water Heating and heat water heat water model Refrigeration displays snowflake symbol Heating displays sun symbol When the unit is off the Refrigeration and Heating mode display the...

Страница 19: ...tank when water temperature symbols air conditioning temperature no water symbol There is water symbols display the temperature of water tank but display A C water temperature there is not Refrigerati...

Страница 20: ...hing begin set Parameter Name Unit No Default setting MAX MIN Refrigerating P1 12 30 b6 A C Heat water set temperature P2 40 b7 25 Setting temperature heat water recovery P3 55 b8 10 Combine timing Cy...

Страница 21: ...me button adjust hour clock Then press Set time button minute time flashing Press Time button adjust minute clock Then press Set time button clock sets finished 4 Check Circulation timing Set b7 is fo...

Страница 22: ...password to confirm the last two S3 xx Press Search button if the password conform to maintenance s password and you can enter table 3 to change maintenance s password If the password conforms to the...

Страница 23: ...A7 Xx Factory password changes the middle two A8 Xx Factory password changes the last two A9 Xx Re confirm the password the first two AA Xx Re confirm the password the middle two Ab Xx Re confirm the...

Страница 24: ...e protection selection b9 1 0 1 Yes no Compressor quantity bA 2 1 2 Module number bb 5 1 8 Module upload interval bC 1 1 8 minute Water temperature compensation bd 0 10 10 Antifreeze without Compensat...

Страница 25: ...n the ground source pump ahead of the compressor time C7 60 99 10 Refrigeration heat pump and ground source pump in parallel time C8 60second 99 second 5 second Compressor start protection C9 3minute...

Страница 26: ...0 bC 25 2 Management level parameter set Press Set button long by 10 seconds enter management level parameter set menu the password to enter Press Check button it may choice System function setting me...

Страница 27: ...perature of air condition reach to setting time the unit will stop The inlet water pump is normally open Heating and heat water mode the heat pump and the inlet water pump can run at the same time Whe...

Страница 28: ...function b6 0 When it has Electric then the controller to maintain the original state of startup or shutdown choose compares timing or circulation timing b7 0 0 1 circulation timing circulation runnin...

Страница 29: ...2 Outlet water temperature is too high to protect in heating C3 58 90 40 Air conditioning water temp difference too high protection C4 10 15 2 Heating water temp difference too high protection C5 10...

Страница 30: ...s 12 hours 1 hour Compressor enter the defrost of the cumulative time firstly d2 40minutes 99 minutes 20 minutes defrost of the longest time d3 8 minutes 15 minutes 2 minutes Enter the condition of th...

Страница 31: ...ning pumps to run Four way valve to run section of flow switch electric heating run Ground source pump to run start compressor 2 4 Air conditioning electric heating run When the 5 P2 TI Air conditioni...

Страница 32: ...t operation mode When TS P3 Run air conditioning system hot model Ibid compressor 2 air heating operation 4 2 Run hot water mode hot water pumps open within 1 minute after the air conditioning pump of...

Страница 33: ...ter pipes in winter standby pump Frost Crack the Units to meet the following conditions are automatically entered antifreeze work When the ambient temperature is higher than 10 antifreeze does not sta...

Страница 34: ...t circuit or open circuit System Shutdown Maintenance and replacement sensors The air temperature sensor is damaged E1 13 Sensor short circuit or open circuit System Shutdown Maintenance and replaceme...

Страница 35: ...it or open circuit Stop X Units Maintenance and replacement sensors Air conditioning inlet water sensor is damaged EX 12 Sensor short circuit or open circuit Stop X Units Maintenance and replacement s...

Страница 36: ...Y COMP Maintenance Y High Voltage Fault EX 3Y High Pressure Switch off Stop X Units Y COMP 3 times hour after repair Y low Voltage Fault EX 4Y Low Pressure Switch off Stop X Units Y COMP 3 times hour...

Страница 37: ...let water EX 56 ground source the temperature difference outlet water temperature and the let out water is higher than C5 Stop Units Maintenance Heat outlet water is too high to protect EX 57 When the...