background image

39

  two times.
5.  Press the monitor key again. One long and three short signal tones confirm  
  that channel number 8 has been selected.

8.4.3.2 Pilot tones
Please observe:

After programming is complete, switch the unit off and back on again, so that 
it is back in the operating mode.
All of the CTCSS/DCS pilot tones are listed in the following table. 
After confirmation of a signal number ≥ 10, a short trace occurs between the 
tens and the units.

No.

CTCSS/DCS

No.

CTCSS/DCS

No.

CTCSS/DCS

No.

CTCSS/DCS

0

OFF

25

156,7 Hz

50

D072

75

D261

1

67,0 Hz

26

162,2 Hz

51

D073

76

D263

2

71,9 Hz

27

167,9 Hz

52

D074

77

D265

3

74,4 Hz

28

173,8 Hz

53

D114

78

D271

4

77,0 Hz

29

179,9 Hz

54

D115

79

D306

5

79,7 Hz

30

186,2 Hz

55

D116

80

D311

6

82,5 Hz

31

192,8 Hz

56

D125

81

D315

7

85,4 Hz

32

203,5 Hz

57

D131

82

D331

8

88,5 Hz

33

210,7 Hz

58

D132

83

D343

9

91,5 Hz

34

218,1 Hz

59

D134

84

D346

10

94,8 Hz

35

225,7 Hz

60

D143

85

D351

11

97,4 Hz

36

233,6 Hz

61

D152

86

D364

12

100,0 Hz

37

241,8 Hz

62

D155

87

D365

13

103,5 Hz

38

250,3 Hz

63

D156

88

D371

14

107,2 Hz

39

D023

64

D162

89

D411

15

110,9 Hz

40

D025

65

D165

90

D412

16

114,8 Hz

41

D026

66

D172

91

D413

17

118,8 Hz

42

D031

67

D174

92

D423

18

123,0 Hz

43

D032

68

D205

93

D431

19

127,3 Hz

44

D043

69

D223

94

D432

20

131,8 Hz

45

D047

70

D226

95

D445

Содержание Ex-PMR 1000

Страница 1: ...Ex PMR 1000 Operating Instructions...

Страница 2: ...pre programmed storage spaces 37 8 4 4 Checking the channel storage space settings 41 8 5 Accessories 43 9 Charging the battery module 43 9 1 General Information 43 9 2 LED display Charging process 44...

Страница 3: ...ons If there is any risk that the safety or integrity of the unit has been compro mised the unit must be taken out of operation immediately and removed from the Ex area without delay Action must be ta...

Страница 4: ...cloth 5 General safety instructions 5 1 Transport safety NEVER use a hand held radio unit while operating a vehicle Park the vehicle before answering a call or before placing a call yourself To avoid...

Страница 5: ...s do not hold the radio unit to the ear with the hearing aid In the event of possible disturbances with some types of hearing aids please contact your local service partner 5 3 3 Other medical devices...

Страница 6: ...should not mount any parts in the area claimed by the inflated airbag 5 4 2 Airplanes The use of radio units on airplanes is prohibited in most cases Turn your radio unit off before boarding the airpl...

Страница 7: ...n power 0 5W ERP NF power output max 0 5 W Weight approx 450g including battery pack IP rating IP 54 CE designation 0102 0678 Channel frequency table Channel Frequency MHz Channel Frequency MHz 1 446...

Страница 8: ...ay The red LED display illuminates when transmitting The green LED display illu minates when receiving The red LED flashes when the battery voltage is low ON OFF and volume control Turn the knob clock...

Страница 9: ...ies on the same channel When CTCSS DCS is set the user can only receive the calls on the same channel with the same CTCSS DCS Please observe Although you can ignore unwanted calls with CTCSS DCS this...

Страница 10: ...Set the channel switch to S the radio unit then only automatically records the channels that have been programmed for search run in channels 1 15 If a signal is detected on a channel the radio unit s...

Страница 11: ...oes below a pre set voltage during operati on the red LED display flashes If an alarm sounds the transmission process is aborted Please charge the battery module or replace it with a replacement modul...

Страница 12: ...8 2 Functions Low Battery Warning 8 4 3 Changing the pre programmed storage spaces 8 4 3 1 Channels You can change the frequency allocation of the 16 pre programmed channel storage spaces Select a val...

Страница 13: ...PTT is pressed more often than 8 times a signal tone sounds and no value is selected 5 The respective signal tone of the selected number sounds after 2 seconds 6 Press the monitor key to end this sett...

Страница 14: ...2 Hz 51 D073 76 D263 2 71 9 Hz 27 167 9 Hz 52 D074 77 D265 3 74 4 Hz 28 173 8 Hz 53 D114 78 D271 4 77 0 Hz 29 179 9 Hz 54 D115 79 D306 5 79 7 Hz 30 186 2 Hz 55 D116 80 D311 6 82 5 Hz 31 192 8 Hz 56 D...

Страница 15: ...pace using the channel switch 4 Select the tens digit of the signal number between 0 9 by pressing PTT Each time you press it the signal number changes and is accompanied by a signal tone 5 The respec...

Страница 16: ...signal tones confirm that 2 has been selected 4 Press PTT 5 times to select 5 for the units digit Each time you press it a signal tone will sound 5 After 2 seconds 5 short signal tones confirm that 5...

Страница 17: ...ing the signal tone Number Signal tone Number Signal tone 0 1 second tone 5 1 6 2 7 3 8 4 9 Default values of the channel Channel number Frequenz CTCSS DCS 1 1 446 00625 0 OFF 2 2 446 01875 0 OFF 3 3...

Страница 18: ...rged outside of the Ex area with the designated charger LS PMR 1000 and the corresponding power supply unit PS PMR 1000 9 Charging the battery module 9 1 General Information Turn the radio unit off be...

Страница 19: ...lumi nate When an Ex PMR 1000 with mounted or individual Ex AM PMR 1000 is inserted the LED illuminates in red CHARGING Charging is complete after about 4 hours and the LED illuminates green FULLY CHA...

Страница 20: ...ow weight and high capacity in a nevertheless compact construction In addition these batte ries also exhibit practically no memory effect However these batteries are susceptible to a natural ageing pr...

Страница 21: ...t no cost in accordance with the EC Directive 2002 96 EC and the German Electrical and Electronic Equipment law of 16 03 2005 The costs of the transport of the equipment to ecom instruments GmbH are b...

Страница 22: ...solvents or abrasive cleaning agents to clean the unit We recommended having the function and the accuracy of the unit checked by the manufacturer every two years The storage temperature should be wit...

Страница 23: ...ss of whether they are caused by breach of warranty lawful or unlawful actions actions in good faith or other actions If in certain countries the restriction of statutory warranty and the exclusion or...

Страница 24: ...49 15 EC Type Examination Certificate...

Страница 25: ...vided in the EC type examination certificate remain unchanged Test Report No ZELM Ex 1500515433 Special conditions Not applicable Fundamental safety and health requirements The fundamental safety and...

Страница 26: ...51...

Страница 27: ...he technical data and the labeling as well as the indications in the EC type approval test certificate remain unchanged Test report no ZELM Ex 1500515433 Special conditions not applicable Basic health...

Страница 28: ...radio may also be manufactured in accordance with this 2nd addendum and designated as follows Ignition protection class designation The electrical data and all other specifications as well as the det...

Страница 29: ...reby declares that the unit meets all underlying requirements of the European Directive R TTE 1999 5 EC Further details relating to the declaration of conformity can be found at the following Internet...

Страница 30: ...chlie lich aber nicht be schr nkt auf die stillschweigende Garantie der Markttauglichkeit und der Eignung f r einen bestimmten Zweck es sei denn anwendbare Gesetze oder Rechtsprechungen schreiben zwin...

Отзывы: