59
Mi
sc
.
4.5 Fouled Product Spray
Screens
Low water pressure at the
spraying nozzle in sump
Increase pressure at regulator.
Temperature too hot
Check water temperature. If too
hot, add tempering valve.
Mi
sc
.
4.6 Product consumption
too high
Check product solenoid valves for
proper operation
If the valve does not
immediately close when power is
removed, the diaphragm is weak
and should be replaced.
Check wires and conductivity cell
Ensure cells and wire
connections are pushed in all the
way. Might also need to
clean/wipe off cells.
Mi
sc
4.7 No product feeds
No laundry machine signals
Check laundry machine output
voltage and wiring.
Controller Failure
Verify a valid signal is present at
MSI by watching LEDs light
during washer operation. If the
LEDs
light
, highlight the desired
washer and check the MSI to
controller communication by
selecting
>
on the
controller. If no signal is
displayed on the Condor, replace
controller.
MSI Failure
Verify a valid signal is present at
the MSI by watching the LEDs
light during washer operation. If
the
LEDs do NOT light
, verify
presence of a valid supply signal
with a voltmeter at the MSI
module.
If supply signals are present
,
replace MSI.
Mi
sc
4.8 Not selecting correct
formula
Check Micro-Mode and Manual
Mode settings
Select one or the other.
Failed RS-485 cable
Replace cable.