pag.11
LB1292
MULTIFLAM 500.1 PR - 600.1 PR
techniques for energy saving
OIL DELIVERY ADJUSTMENT
The diagram illustrates the fuel feeding system of these type of burners, which incorporates a by-pass nozz-
le with oil flow regulation on its return pipe. The oil supply is varied by acting on the nozzle through the
pressure in the return line. Max. oil supply is therefore reached when the pressure in the pump line is
about 30 bar and the return line is fully closed; min. oil supply when the return line is fully open(see also
diagram BERGONZO). Relevant pressure readings in the return line are as follows (return oil pressure has
to be measured on “M” pressure gauge): - max. oil supply : 20 to 30 bar in the pump.
- min. oil supply : 3 to 24 bar in the return.