pag.22
420010399601
MULTICALOR 170.1 -200.1 P AB
EN
Remove cover to gain access to the adjusting cams.The cams are to be
adjusted through the suitable key provided for. Description:
I -
Limit switch for air damper “High Flame” position adjustment
(Max. power).
II -
Limit switch for the air damper position at burner’s shut down
III -
Limit switch for air damper “Low Flame” position adjustment
(Min. power).
V -
Limit switch for 2nd stage’s solenoid valve opening release
NOTE :
Cam V (to allow the 2nd stage’s solenoid valve opening) must
be adjusted to an intermediate position between the Low and High
Flame ones (to an angle approximately 5° greater than the low flame
position).
MANUAL RELEASE
SWITCH
SIEMENS SQN 30 151A2700 AIR DAMPER MOTOR
”PAB” VERSION GAS BURNERS GAS TRAIN INSTALLATION AND SETTING INSTRUCTIONS
Fix the gas train to burner body by means of the screws of the flange, pay attention to set correctly the gasket. Connect
electrically the gas train with the 6 pole plug.
Switch on the burner (it has already been tested in the factory, so it is pre set on average values) and verify the tightness
of gas train connections made during installation. Act as follows to adapt the burner output to the boiler.
High flame
1. Bring the burner in high flame , air inlet must be set at 75 ° (maximum opening position).
To adjust air capacity operate on the combustion head position. Just in peculiar case it is necessary to reduce the air
flow in high flame closing air intake damper.
2. The position of gas butterfly valve must be lower then 90° ( typically 85°. It is important not get over 90° to obtain
a perfect combustion during passage from high to low flame). Eventually adjust this position by shaft B after
loosening the screw A.
3. Regulate gas capacity in high flame through the gas
governor, or operate on the adjustable gas valve.
Attention: the instructions for gas valves setting
are included in the gas train manual.
Low flame
4. Choose the first stage position on the servocontrol
(normally between 10°-30°) on the basis of the redu-
ced charge
output required and
switch the burner to low flame.
5. Regulate gas capacity, to obtain optimal combu-
stion. To adjust the butterfly valve position act upon
hexagonal bar
C after loosening
nuts D.
Final operations
6. Bring the burner in high flame again, if necessary
adjust again gas flow (as shown in point n.2).
7. If necessary repeat operations described on point n.
5 and n. 6 until You obtain the exact position of
the gas flow both in high and low flame.
8. Fix the nuts.
B
A
D
C
D