background image

8

4. COMPLETE INLET AND OUTLET

PLUMBING

Pipe fittings must be 3/4” minimum.
Use:

=

Copper pipe

=

Threaded pipe

=

PEX (Crosslinked Polyethylene) pipe

=

CPVC plastic pipe

=

Other pipe approved for use with potable water

IMPORTANT:

Do not solder with plumbing attached to

installation adaptors and single bypass

valve.  Soldering heat will damage the

adaptors and valve.Measure, cut, and

loosely assemble pipe and fittings from

the main water pipe to the inlet and out-

let ports of the water softener valve.  Be

sure to keep fittings fully together, and

pipes squared and straight.

Be sure hard water supply pipe goes to the water sof-

tener valve inlet side.

NOTE:

Inlet and outlet are marked on the water sof-

tener valve.  Trace the water flow direction to

be sure hard water is to inlet.

IMPORTANT:

Be sure to fit, align and support all

plumbing to prevent putting stress on

the water softener valve inlet and outlet.

Stress from misaligned or unsupported

plumbing may cause damage to the

valve.

Complete the inlet and outlet plumbing for the type of

pipe you will be using.

5. COLD WATER PIPE GROUNDING

CAUTION:

The house cold water pipe (metal only) is

often used as a ground for the house elec-

trical system,  The 3-valve bypass type of

installation, shown in Figure 8, will maintain

ground continuity.  If you use a plastic

bypass valve at the unit, continuity is bro-

ken.  To restore the ground, do the follow-

ing:

a. Install the included metal ground clamp across the

removed section of main water pipe, securely tight-

ening the hardware at the center (See Figure 11).

NOTE:

Check local plumbing and electrical codes for

proper installation of grounding.  The installa-

tion must conform to them.  In Massachusetts,

plumbing codes of Massachusetts shall be

conformed to.  Consult with your licensed

plumber.

FIG. 11

Ground

Clamp

Inlet / Outlet

Pipes

6. INSTALL VALVE DRAIN HOSE

a

. Measure, cut to needed length and connect the 3/8"

inside diameter drain line (provided with some mod-

els) to the water softener valve drain fitting.  Use a

hose clamp to hold the hose in place.

Installation Instructions

NOTE:

Avoid drain hose

runs longer than 30

feet.  Avoid elevat-

ing the hose more

than 8 feet above

the floor.  Make the

valve drain line as

short and direct as

possible.

NOTE:

If codes require a

rigid drain line see

Figure 13.

b

. Route the drain hose or

copper tubing to the

floor drain.  Secure

drain hose.  This will

prevent “whipping'' dur-

ing regenerations.  See

“Air Gap Requirements"

section.

FIG. 12

FIG. 13

Drain Fitting

on valve

Valve

Drain

Hose

1-1/2”

Air Gap

To

Floor

Drain

CONNECTING A RIGID VALVE DRAIN TUBE:

To adapt a copper drain tube to the softener, cut the

barbed end from the drain fitting, as shown.  Obtain a

compression fitting (1/4” female pipe thread x 1/2” O.D.

tube) and needed tubing from your local hardware store.

1/4” NPT Threads

Clip

Compression Fitting,

1/4” NPT x 1/2” O.D.

tube (not provided)

Cut barbs from drain fitting

1/2” O.D. copper tube

(not provided)

Содержание EP 6130

Страница 1: ...Electronic Demand AUTOMATIC WATER CONDITIONER Installation Operation Maintenance Repair Parts Manufactured and warranted by Ecodyne Water Systems 1890 Woodlane Drive Woodbury MN 55125 Systems tested...

Страница 2: ...tronic Controller 11 12 Controller Features Options 13 Routine Maintenance 14 Troubleshooting 15 17 Exploded View Parts List 18 23 Warranty 24 3 3 8 41 1 4 48 3 4 14 OUTLET INLET 39 INLET OUTLET B A D...

Страница 3: ...es greater than the service flow rate may affect capacity and efficiency performance Capacity to reduce clear water iron is substantiated by WQA test data State of Wisconsin requires additional treat...

Страница 4: ...20V 60 cycle household outlet that is in a dry location only grounded and properly protected by an overcurrent device such as a circuit breaker or fuse Power consumption is 13 5 W maximum and 1 0 W ty...

Страница 5: ...ipes Outside faucets should remain on hard water to avoid wasting conditioned water and salt A nearby drain is needed to carry away regenera tion discharge drain water Use a floor drain laundry tub su...

Страница 6: ...ded 1 NPT Installation Adaptor 2 O ring Seal 2 Bypass Valve Clip 4 Included with softener Pipe and fittings supplied by installer Valve INLET Valve INLET 1 NPT Installation Adaptor 2 O ring Seal 2 Cli...

Страница 7: ...port and observe the turbine for free rotation d Snap the two large plastic clips in place on the inlet and outlet ports from the top down See Figure 9 Make sure they snap into place Pull on the bypas...

Страница 8: ...the ground do the follow ing a Install the included metal ground clamp across the removed section of main water pipe securely tight ening the hardware at the center See Figure 11 NOTE Check local plu...

Страница 9: ...b bles then close this faucet f Close all cold water faucets and check for leaks at the plumbing connections that you made g Check for leaks around clips at softener s inlet and outlet If a leak occur...

Страница 10: ...ow However during shipping storage installation and operation bacteria could get into the unit For this reason sanitizing as follows is suggested when installing a Open the salt lid remove the brinewe...

Страница 11: ...ELECT button a few times until they do 1 Press the UP or DOWN buttons to set the present time Up moves the display ahead down sets the time back Be sure AM or PM is correct NOTE Press buttons and quic...

Страница 12: ...regener ate when you are away from home for extended peri ods unless you program the Maximum Days Between Regenerations feature see next page FIG 23 Programming the Electronic Controller FIG 20 FIG 21...

Страница 13: ...mines regeneration frequency This provides the greatest operating efficiency and under most conditions this feature will be left in its default mode However you can set this feature to force a regener...

Страница 14: ...dissolve in the water to make brine Without brine the resin bed is not recharged and hard water will result If the storage tank is full of salt it is difficult to tell if you have a salt bridge A brid...

Страница 15: ...charging Avoid using hot water during recharges because water heater refills with hard water Increase in actual hardness of water supply Have unsoftened water sample tested Check the current Hardness...

Страница 16: ...If you get a reading in the display with the magnet unhook the in and out plumbing and check the turbine for binding See Figure 32 3 The last 2 digits in the display indicate position switch operation...

Страница 17: ...brine tank by shining a flashlight into the brinewell and observing a noticeable drop in the liquid level NOTE Be sure water is in contact with the salt and not separated by a salt bridge If the water...

Страница 18: ...18 Softener Exploded View Models EP 6130 EP 6225 EP 6245 EP 6260 1 Valve Assembly See Pages 20 23 for parts 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 22 18 20 19 21 27 23 24 25 26 29 28...

Страница 19: ...Models EP 6130 EP 6225 7302738 Faceplate Decal Models EP 6245 EP 6260 14 7303213 Repl Electronic Control Board PWA 15 7275907 Transformer Key No Part No Description 16 7192785 Salt Cover Model EP 6130...

Страница 20: ...lve Exploded View Models EP 6130 EP 6225 70 91 51 50 52 53 55 56 59 58 57 60 61 66 67 62 63 64 68 69 70 71 72 73 74 75 65 76 77 79 78 80 81 82 Wear Strip Seal Cross section View 83 84 85 86 87 88 89 9...

Страница 21: ...pring 70 7337563 Clip 3 4 pack of 4 71 7278442 Installation Adaptor 3 4 2 req including O Ring See Key No 72 Key No Part No Description 72 7337571 O Ring 15 16 x 1 3 16 pack of 4 7113040 Turbine Suppo...

Страница 22: ...5 EP 6260 Wear Strip Seal Cross section View 100 101 102 103 104 105 106 107 108 109 110 111 112 117 118 140 113 114 115 119 120 116 127 121 145 123 121 122 123 124 125 126 128 129 131 130 132 133 134...

Страница 23: ...eq 123 7311127 O Ring 1 1 16 x 1 5 16 4 req Key No Part No Description 7290931 Turbine Support Assembly includes Key Nos 124 125 124 Turbine Support Shaft 125 Turbine 126 7309811 Wire Harness Sensor 1...

Страница 24: ...placement part directly to your home without charge After the first year labor necessary to maintain this product is not covered by the product warranty General Provisions Damage to any part of this w...

Отзывы: