background image

COMFORT DUO RF

 

 

Press 

 key to cancel temperature 

HOLD mode and return to Run 
PROG mode. 

 

 

 5 

 

HOLIDAY 

 

HOLIDAY hold allows you to setup the desired 
temperature while you are away from home or on 
vacation to reduce the energy consumption. Activate 

HOLIDAY hold by pressing key 

 4 times. 

Use the key 

 to select the 

desired temperature. The 
temperature setting range is from 
0°C to 10°C. 

 

Press 

 key to confirm the 

temperature setting. 

Use the key 

 to 

increase/decrease the number of 
HOLIDAY days. LCD shows the 
number of the days under Holiday 
hold mode and the date indicates 
when the HOLIDAY hold mode will 
expire. 

Press 

to confirm the HOLIDAY hold settings and 

activate Holiday hold mode. 

Press 

 to cancel the HOLIDAY hold mode and 

return to Run PROG mode. 

If the temperature setting is under 
5°C. the frost protection will be 

triggered and the icon 

 appears 

on LCD. 

 

 

 6 

 

Standby Function 

 

This thermostat offers a Standby 
function that allows you to turn off 
your heating system when not 
required, while the thermostat keeps 
monitoring the room temperature 
and calls for heating, should there be 

a risk of frost damage. 

1. Activate Standby function by pressing 

 key, 

power icon 

 and frost protection icon 

 will 

appear on LCD. 

2. Press the key 

 to deactivate the Standby function 

and return to Run PROG mode. Power 

 icon

 

and frost protection icon will disappear from LCD. 

 7 

 

Key Lock function

 

 

This function allows you to lock the operation keys on 
this thermostat. 

1.Lock the Operation keys 

Press and hold both 

 & 

 keys simultaneously for 

about 5 seconds until the key lock icon 

 appears on 

the LCD. 

2.Release Key Lock function 

Press and hold 

 & 

keys simultaneously again for 

about 5 seconds until the key lock 

 icon disappears 

from the LCD. 

 8 

 

Battery Low indication 

 

When the battery voltage becomes too low for reliable 
operation, battery low icon will appear on LCD 

 

,and the batteries must be replaced as soon as 
possible. 

 9 

 

Change program period settings:

 

1. Press key to enter "Standby" 

mode. 

 

 

 

2. Press and hold 

 key for about 

5 seconds until appears on LCD. 

 

 

 

3. Factory default is 6 periods per day 

4. Press 

 to change the program period as desired.  

 

 

 

 

 

5. Press 

to save the change 

and return to Standby mode. 

6. Press 

 to retrun to Run 

Prog mode. 

 

Содержание COMFORT DUO RF

Страница 1: ...fort Override mode maintains the room temperature on the desired setpoint during a set period of time from 1 9 hours Manual override User settings can be retained when the thermostat is power off 2 Technical data Temperature control range 5 35 C Comfort setpoint adjustment range 5 35 C Temperature adjustment scale 0 5 C Temperature offset calibration range 3 5 C Temperature reading calibration inc...

Страница 2: ...e P2 8 00 29ºC 14 ºC Return P5 18 00 25ºC 21 ºC Sleep P6 22 00 27ºC 16 ºC PROG 2 period per day Program Time Cool Heat Wake P1 6 00 25ºC 21 ºC Sleep P2 22 00 29ºC 16 ºC 4 2 LCD Display Descriptions Key lock Frost Protection Heating on Battery Low Standby Mode Run Prog Wake Run Prog Leave Run Prog Occupied Run Prog Unoccupied Run Prog Return Run Prog Sleep Setting Mode DAY MoTuWeThFrSaSu MON TUE WE...

Страница 3: ...G Press the key to start programming Press to enter the program setting for day of the week SET PROG Press to enter PROG COPY function Press to return to Run PROG mode 4 1 Set PROG A Press to enter the program setting You will see Mo and P1 temperature reading is flashing Each day of the week can be individually programmed B Press the key to set desired temperature for P1 program period C Press th...

Страница 4: ... for copy are completed The display returns to start PROG setting mode 5 Set Differential Press the key to select the settings for Operating mode Press to change between TPI and ANALOGE operationg mode and press to select the desired one 5 1 Analoge operating mode Once selected the Analoge operating mode press key to change value 0 5 1 1 5 2 the default value is 0 5 Press to save the changed value...

Страница 5: ...oom code of your device Press to enter RF Room code setting In order to pair with RV receiver please set a code from 0 15 Attention After setting the room code please remember to set the dip switch on RV receiver For dip switch setting please refer the form below Press key to save the setting 10 Test RF signal strength of location 1 To test your devices location are good or not 2 When the ventilat...

Страница 6: ...NUAL override will expire Press key to cancel the MANUAL override mode and return to Run PROG mode 3 COMFORT override COMFORT override allows you to change the temperature for a specific number of hours from one to nine without altering the thermostat s program The thermostat will use the new temperature setting for the specified amount of time then the thermostat will return to run the programmed...

Страница 7: ...mostat keeps monitoring the room temperature and calls for heating should there be a risk of frost damage 1 Activate Standby function by pressing key power icon and frost protection icon will appear on LCD 2 Press the key to deactivate the Standby function and return to Run PROG mode Power icon and frost protection icon will disappear from LCD 7 Key Lock function This function allows you to lock t...

Страница 8: ...ds of blue cover by screw driver and make the electrical connections according to the following scheme N Neutral 230 V C Cooling L Phase 230 V F Fans fancoils H Heating COM Common Operating Instruction RF code ID setting 1 Check RF code to match with the transmitter s RF code Initial code setting is 0000 All pins are downward 2 RF LED indicator on the right next to reset A The LED will keep lighti...

Отзывы: