background image

COMFORT DUO RF

 

6) OPERATION 

Contents 

1.---RUN PROG 

         7.---Key lock 

2.---Manual override           8.---Battery low indicator 

3.---Comfort hour override   9.---Change day program 

4.---Temperature hold         10.--System mode 

5.---Vacation mode 

        11.--Fan mode 

6.---Standby off 

 1 

 

RUN PROG Normal display Descriptions

 

 

 

Key Operate descriptions: 

In Run PROG mode 

, you can press 

 key to 

select the desired mode, MANUAL override, 
COMFORT hour, temperature HOLD, or HOLIDAY, 
according to the indication on LCD. 

 2 

 

Manual override 

 

Temporary Override is available enabling you to 
temporarily change the temperature without

 altering 

the thermostat's program. The thermostat will use 
the new temperature setting during the duration of 

this program period. Override function will be 
terminated when the next program period starts to run 
the programmed temperature setpoints. 

Activate MANUAL Override by pressing 

 key. Press 

the 

 or 

 key to manually adjust the desired 

temperature setting. 

 

 

Press 

  

 

 

 

Press 

 to activate the temporary override mode, 

 

appears on the display. The time indicates when the 
MANUAL override will expire. Press key to cancel the 
MANUAL override mode and return to Run PROG 
mode. 

 

COMFORT override 

 

  

 

COMFORT override allows you to change the 
temperature for a specific number of hours (from one 
to nine) without altering the thermostat's program. The 
thermostat will use the new temperature setting for the 
specified amount of time, then the thermostat will 
return to run the programmed temperature setpoints. 

Activate COMFORT Override by pressing 

 key 

twice. 

1. Simply adjust the set temperature (Temp. Set to) by 

using  

key. 

2. Press 

 key to confirm the adjusted temperature 

and go to the setting of COMFORT Hours. 

3. Press 

 key to select the COMFORT Hours. 

LCD indicates “COMF:1H”, “1” will be flashing as 
for adjustment. 

 

4. Press 

 to confirm the settings and activate the 

COMFORT override mode, 

 

 appear on the 

display. The time indicates when the COMFORT 
override mode will expire. 

5. Press 

 key to cancel the COMFORT override 

mode and return to Run PROG mode. 

 4 

 

Temperature Hold 

 

Temperature HOLD allows you to maintain a constant 
temperature and disable temperature program 
periods. 

Activate temperature HOLD by pressing 

 key 3 

times. 

Simply adjust the set temperature by using the 

 

key. 

 
 
Press 

 to activate temperature 

HOLD mode. 

 

Содержание COMFORT DUO RF

Страница 1: ...fort Override mode maintains the room temperature on the desired setpoint during a set period of time from 1 9 hours Manual override User settings can be retained when the thermostat is power off 2 Technical data Temperature control range 5 35 C Comfort setpoint adjustment range 5 35 C Temperature adjustment scale 0 5 C Temperature offset calibration range 3 5 C Temperature reading calibration inc...

Страница 2: ...e P2 8 00 29ºC 14 ºC Return P5 18 00 25ºC 21 ºC Sleep P6 22 00 27ºC 16 ºC PROG 2 period per day Program Time Cool Heat Wake P1 6 00 25ºC 21 ºC Sleep P2 22 00 29ºC 16 ºC 4 2 LCD Display Descriptions Key lock Frost Protection Heating on Battery Low Standby Mode Run Prog Wake Run Prog Leave Run Prog Occupied Run Prog Unoccupied Run Prog Return Run Prog Sleep Setting Mode DAY MoTuWeThFrSaSu MON TUE WE...

Страница 3: ...G Press the key to start programming Press to enter the program setting for day of the week SET PROG Press to enter PROG COPY function Press to return to Run PROG mode 4 1 Set PROG A Press to enter the program setting You will see Mo and P1 temperature reading is flashing Each day of the week can be individually programmed B Press the key to set desired temperature for P1 program period C Press th...

Страница 4: ... for copy are completed The display returns to start PROG setting mode 5 Set Differential Press the key to select the settings for Operating mode Press to change between TPI and ANALOGE operationg mode and press to select the desired one 5 1 Analoge operating mode Once selected the Analoge operating mode press key to change value 0 5 1 1 5 2 the default value is 0 5 Press to save the changed value...

Страница 5: ...oom code of your device Press to enter RF Room code setting In order to pair with RV receiver please set a code from 0 15 Attention After setting the room code please remember to set the dip switch on RV receiver For dip switch setting please refer the form below Press key to save the setting 10 Test RF signal strength of location 1 To test your devices location are good or not 2 When the ventilat...

Страница 6: ...NUAL override will expire Press key to cancel the MANUAL override mode and return to Run PROG mode 3 COMFORT override COMFORT override allows you to change the temperature for a specific number of hours from one to nine without altering the thermostat s program The thermostat will use the new temperature setting for the specified amount of time then the thermostat will return to run the programmed...

Страница 7: ...mostat keeps monitoring the room temperature and calls for heating should there be a risk of frost damage 1 Activate Standby function by pressing key power icon and frost protection icon will appear on LCD 2 Press the key to deactivate the Standby function and return to Run PROG mode Power icon and frost protection icon will disappear from LCD 7 Key Lock function This function allows you to lock t...

Страница 8: ...ds of blue cover by screw driver and make the electrical connections according to the following scheme N Neutral 230 V C Cooling L Phase 230 V F Fans fancoils H Heating COM Common Operating Instruction RF code ID setting 1 Check RF code to match with the transmitter s RF code Initial code setting is 0000 All pins are downward 2 RF LED indicator on the right next to reset A The LED will keep lighti...

Отзывы: