COMFORT DUO RF

 

4-2. PROG copy 

Press the 

 key to select the settings for PROG. 

Press the 

 key to start programming. 

  

 Press  

    

     

Prog Copy function:  

Before copying the program, please select any day of 
the week and complete entire temperature set points 
for each program period of the day. (Read 
Programming procedure described in the step 4-1. Set 
PROG). 

Press 

 to enter “PROG COPY” function. ‘-From' 

MoTuWeThFrSaSu

 lit on the LCD (Choosing the 

reference-day “from”). 

 

Take the selected day as reference-day for “Copy” 
function, and follow the instructions below: 

A. Press 

 to select the reference-day.  

B. Press 

 after reference-day is selected, ‘To' will 

lit on LCD. 

 

C. Press 

 to select the day of the week for the 

programs to be copied to.  

Press 

 as confirmation. 

 

D. Repeat the steps by pressing 

 and 

 to 

select more days to copy the programs to or press 

 to delete the previously selected day of the 

week (flashing). 

E. Press 

 after desired days for “copy” are 

completed. The display returns to start PROG 
setting mode. 

 

 5 

 

Set Differential 

Press the 

 key to select the settings for Operating 

mode. 

 

 
Press  

 to change between TPI and ANALOGE 

operationg mode and press 

 to select the desired one. 

 

5-1 Analoge operating mode 

Once selected the Analoge operating mode, press 

 key to change value.0.5/1/1.5/2, the default 

value is 0.5).  

Press 

 to save the changed value. 

 

5-2 TPI operting mode 

CPH: Cicles per hour 

Once selected the TPI operating mode, press   

 

key to change CHP value: 3/6/9/12, (the default value is 
6). 

Press 

 to save the changed value and change to P-

BAND parameter. 

Through this parameter the number of modulation cycles 
per hour is selected. In other words, if CPH=6 the 
thermostat will do 6 modulation cycles, so each cycle will 
last for 10 minutes. 

 

P-BAND: Modulation range 

Press again   

 key to change P-BAND value: 1,5 

ºC – 3 ºC (the default value is 1,5 ºC). 

Press  

 to save the changed value. 

This parameter selects the temperature range in which 
the modulation is activated. For example, if P-BAND=2 
the modulating will be activated between the Set 
Temperature ±1 ºC. 

 

Содержание COMFORT DUO RF

Страница 1: ...fort Override mode maintains the room temperature on the desired setpoint during a set period of time from 1 9 hours Manual override User settings can be retained when the thermostat is power off 2 Technical data Temperature control range 5 35 C Comfort setpoint adjustment range 5 35 C Temperature adjustment scale 0 5 C Temperature offset calibration range 3 5 C Temperature reading calibration inc...

Страница 2: ...e P2 8 00 29ºC 14 ºC Return P5 18 00 25ºC 21 ºC Sleep P6 22 00 27ºC 16 ºC PROG 2 period per day Program Time Cool Heat Wake P1 6 00 25ºC 21 ºC Sleep P2 22 00 29ºC 16 ºC 4 2 LCD Display Descriptions Key lock Frost Protection Heating on Battery Low Standby Mode Run Prog Wake Run Prog Leave Run Prog Occupied Run Prog Unoccupied Run Prog Return Run Prog Sleep Setting Mode DAY MoTuWeThFrSaSu MON TUE WE...

Страница 3: ...G Press the key to start programming Press to enter the program setting for day of the week SET PROG Press to enter PROG COPY function Press to return to Run PROG mode 4 1 Set PROG A Press to enter the program setting You will see Mo and P1 temperature reading is flashing Each day of the week can be individually programmed B Press the key to set desired temperature for P1 program period C Press th...

Страница 4: ... for copy are completed The display returns to start PROG setting mode 5 Set Differential Press the key to select the settings for Operating mode Press to change between TPI and ANALOGE operationg mode and press to select the desired one 5 1 Analoge operating mode Once selected the Analoge operating mode press key to change value 0 5 1 1 5 2 the default value is 0 5 Press to save the changed value...

Страница 5: ...oom code of your device Press to enter RF Room code setting In order to pair with RV receiver please set a code from 0 15 Attention After setting the room code please remember to set the dip switch on RV receiver For dip switch setting please refer the form below Press key to save the setting 10 Test RF signal strength of location 1 To test your devices location are good or not 2 When the ventilat...

Страница 6: ...NUAL override will expire Press key to cancel the MANUAL override mode and return to Run PROG mode 3 COMFORT override COMFORT override allows you to change the temperature for a specific number of hours from one to nine without altering the thermostat s program The thermostat will use the new temperature setting for the specified amount of time then the thermostat will return to run the programmed...

Страница 7: ...mostat keeps monitoring the room temperature and calls for heating should there be a risk of frost damage 1 Activate Standby function by pressing key power icon and frost protection icon will appear on LCD 2 Press the key to deactivate the Standby function and return to Run PROG mode Power icon and frost protection icon will disappear from LCD 7 Key Lock function This function allows you to lock t...

Страница 8: ...ds of blue cover by screw driver and make the electrical connections according to the following scheme N Neutral 230 V C Cooling L Phase 230 V F Fans fancoils H Heating COM Common Operating Instruction RF code ID setting 1 Check RF code to match with the transmitter s RF code Initial code setting is 0000 All pins are downward 2 RF LED indicator on the right next to reset A The LED will keep lighti...

Отзывы: