Chapter I Page 5
I.3. Hidraulic Control Panel.
The control panel shown in the diagram in Chapter I on Page 1 is
made up of a flow meter (12) indicating the production of
freshwater, a low-pressure pressure gauge (5) and a three-way
valve (11), which should be connected up as follows:
•
Blue Ø 8 polyamide tube to connect the end cap plastic
adaptor (10), located in the membrane vessel inlet, to the
elbow located in the lower part of the flow meter (12).
•
Blue Ø
8 polyamide tube to connect the three way valve “main tank” outlet (11) to
the boat main tank.
•
Blue Ø
8 polyamide tube from the 3way valve
“MAIN TANK”
outlet (11) to the boat´s
main tank.
•
Blue Ø
8 polyamide tube from the 3way valve
“PRUEBA/TEST”
outlet (11) to an
accessible fresh water point, such as a tap installed in the kitchen.
•
Blue Ø
6 polyamide tube between the gauge (5) and the filter adapter located in the
top of the low pressure filter vessel (6). There must not be any constrictions in this
tube.
I.4. Electrical Connection.
The system is equipped with a motor for the low-pressure pump 12/24V DC 550 rated watts
at 2000 rpm. It must be connected up using moisture shielded cable with a cross-section that
is appropriate for the distance between the batteries and the motor. Te recommended cables
are the following:
These sections are appropriate to prevent voltage losses greater than 1.6% of the rated
voltage (0.2 V in 12 V DC).
•
Make sure the rotation direction in the pump is correct, which is marked by the water
inlet and the outlet, if it doesn’t, reverse the polarity on the motor
connection.(Chapter I Page 6 )
As a general rule, the electricity grid circuit should be suitably protected, taking care
to oversize the connection cables to avoid voltage drops, besides an unnecessary power
consumption.
Содержание WATER-PRO MODULAR B-60
Страница 4: ...CHAPTER I INTALLATION OPERATION AND MAINTENANCE ...
Страница 14: ...CHAPTER II STORAGE AND CLEANING ...
Страница 19: ...CHAPTER III PARTS LISTING EXPLODED VIEW OF THE ST 15 CERAMIC ECO SISTEMS PUMP ...
Страница 23: ...CHAPTER IV FILTERS AND MEMBRANE REPLACEMENT ...
Страница 26: ... F L O W E N T R A D A S A L I D A 1 2 3 7 M A X 9 3 5 m m Chapter IV Page 3 ...