Chapter IV Page 2
•
The seal is located only in one side of the membrane, the outlet side. There is no seal
in the inlet side.
•
Check that the membrane permeation tube fits properly into the O-rings inside the
sealing caps (7).
•
Place the membrane and screw the end caps previously removed, with the pivot
wrench.
•
Reassemble the vessel on its supports.
•
Reconnect the high pressure hoses, making sure the fitting nuts are well tight.
Connect the fresh wáter outlet.
NOTE:
De location of the seal on the membrane, is different tan in the 2540 Standard model, it
is placed on the side marked as (OUTLET) with its lips against the water flow direction
(FLOW).
Before restarting the unit, make sure the valve (11) (see drawing in Chapter I, Page 1) is in
the
“PRUEBA/TEST”
position and proceed as indicated in Chapter I section 5 FIRST START-
UP following all the steps set out in that section in detail.
WARNING.- The membrane may have air inside and it needs a few minutes to be
completely taken out.
Содержание WATER-PRO MODULAR B-60
Страница 4: ...CHAPTER I INTALLATION OPERATION AND MAINTENANCE ...
Страница 14: ...CHAPTER II STORAGE AND CLEANING ...
Страница 19: ...CHAPTER III PARTS LISTING EXPLODED VIEW OF THE ST 15 CERAMIC ECO SISTEMS PUMP ...
Страница 23: ...CHAPTER IV FILTERS AND MEMBRANE REPLACEMENT ...
Страница 26: ... F L O W E N T R A D A S A L I D A 1 2 3 7 M A X 9 3 5 m m Chapter IV Page 3 ...