Chapter I Page 9
I.8. Maintenance of the unit.
•
Regularly check the status of the sea strainer (3) and clean the mesh of dirt when
needed.
•
Change the 5 micron filter for a new cartridge when you see that pressure has risen
between 0.5 kg/cm
2
and 1 kg/cm
2
above the one indicated on the control panel low-
pressure pressure gauge at the start of operation with a new filter. This cartridge must
always be replaced at the beginning of each season or at least once every three
months in the event of continuous service.
•
Change the active carbon cartridge at least once a year.
•
When the high-pressure pressure gauge (9) exceeds 65 kg/cm
2
(with a water
temperature around 18ºC and 25ºC), the used membrane should be replaced by a new
one.
•
Regularly check if the pressure in the accumulator tank (7) is 7 kg/cm
2
(An annual inspection by the Technical Support Service is recommended).