11
ECM ERROR
CODE
LED ACTION
DESCRIPTION OF ERRORS
0x0000
Grn ON
All OK, (green led constantly on)
0x0001
Flash Grn 10Hz
Sensor warm-up period
0x0002
Grn/Both/Red 2s Power on reset/ Init hardware
0x0011
Pulse Red 1x/2s 16b ADC failed to init
0x0012
Pulse Red 1x/2s +Vsw shorted
0x0013
Red ON
Sensor turned off (red led constantly on)
0x0014
Pulse Red 1x/2s HTR open
0x0015
Pulse Red 1x/2s HTR shorted
0x0021
Pulse Red 2x/2s 1wire bus shorted
0x0022
Pulse Red 2x/2s No 1wire present
0x0023
Pulse Red 2x/2s CRC16 error
0x0024
Pulse Red 2x/2s Invalid 1wire parameter (sensor type)
0x0025
Pulse Red 2x/2s 1-wire data format not compatible (old rev)
0x0031
Pulse Red 3x/2s +Vsw < 6 for > 7sec
0x0032
Pulse Red 3x/2s +Vsw > 30V
0x0041
Pulse Red 4x/2s VS too high
0x0051
Pulse Red 5x/2s RVS too high
0x0052
Pulse Red 5x/2s (VHcommanded - VHactual) > 0.5V for > 10sec
0x0061
Pulse Red 6x/2s VP+ > 6V
0x0062
Pulse Red 6x/2s VP+ < 2V
0x0063
Pulse Red 6x/2s VP2 out of range (NOxCAN* only)
0x0064
Pulse Red 6x/2s 0.15V > VS+ > 0.75V for 7.5 sec.
0x0065
Pulse Red 6x/2s User data (span) in 1wire corrupted (user must set new
span)
0x00A1
N/A
Invalid software state
0x00B1
N/A
CAN overrun
0x00B2
N/A
CAN passive mode
0x00B3
N/A
CAN heartbeat error
0x00B4
N/A
CAN recover bus off
0x00B5
N/A
CAN Tx CanId collision
0x00B6
N/A
Serial overrun
0x00FF
Both ON
Module powering down within 500ms
ECM AUX
N/A
Sensor Warm-up count down in seconds (active during ECM
Error Code 0x0001)
Table 3: LambdaCAN and NOxCAN* Error Codes List