13
When first entering SYS mode, either “MOd” will be on the top display or “LOCK” will be
on the bottom display. If “MOd” is displayed, the
and
keys will roll through the setup
options (see Table 4). First the options for the module assigned to the top display are shown
on the top display, followed by identical options for the module assigned to the bottom
display, ending with the global CONF (Configuration) setup. Pressing the ENT key will
select the displayed setup option and allow its programming.
If “LOCK” is displayed, the dashCAN* has been locked and its setup cannot be changed until
it is unlocked. Appendix G describes how to LOCK and unlock dashCAN*.
Setup Option Level 1
Function
MOd
Select module s/n to be assigned to the display. Default is NONE.
RATE
Set parameter averaging rate. Range 0.001 to 1.000
Default is 1.000. 1.000 means no averaging.
AOUT ( only)
A1 Program analog output 1 from module assigned to top display
A2 Program analog output 2 from module assigned to top display
A3 Program analog output 3 from module assigned to top display
A4 Program analog output 4 from module assigned to bottom display
A5 Program analog output 5 from module assigned to bottom display
A6 Program analog output 6 from module assigned to bottom display
AOUT (dashCAN2 only)
A1 Program analog output 1 from module assigned to top display
A2 Program analog output 2 from module assigned to bottom display
dISP Select parameter. Note: Parameters available are those
contained in TPDOs programmed to be transmitted from
the module (programmed using the Configuration Tool).
CONF LEdS only. Set display intensity. Default is 3333.
dashCAN and dashCAN2 have a knob for display intensity.
1V4V dashCAN2 and only. Command 1V and 4V outputs.
LOCK Lock and Unlock Display for Programming
MOd, RATE, AOUT, and dISP appear on the top display for the module assigned to the top
display and then on the bottom display for the module assigned to the bottom display. CONF
just appears on the bottom display and is for global dashCAN* setup. All entries must be
followed by pressing the ENT key.
Table 4: Menu Tree for dashCAN*
Содержание LambdaCAN Series
Страница 22: ...18 Appendix A LambdaCAN Kit Contents P N 12 02 P N 10 35 LambdaCANp only P N 10 04 LambdaCAN LambdaCANd only...
Страница 48: ...44...
Страница 49: ......
Страница 50: ...Los Altos CA 94023 0040 USA 408 734 3433 Fax 408 734 3432 www ecm co com...