62 GEO3.5 MANUAL
SYMPTOM
POSSIBLE CAUSE
SOLUTION
The GEO3.5 does not fire
The micro-switch is not being activated
Adjust the micro-switch activation screw accordingly
The micro-switch is damaged
Replace the circuit board
The PCB is damaged
The solenoid valve is damaged
Replace the solenoid valve
The solenoid valve wires are damaged
The GEO3.5 does not cycle fully
The bolt assembly is dirty or incorrectly lubricated
Clean, re-lubricate and replace the o-rings on the
bolt as necessary
The Dwell parameter is set too low
Increase the Dwell parameter
A sticky or faulty poppet in the solenoid manifold
Check the poppet, clean and replace as necessary
The GEO3.5 is inconsistent
The Dwell parameter is set too low
Increase the Dwell parameter
The Solenoid Flow Restrictor (SFR) is set too low
Increase the flow through the SFR
Using poor quality paintballs
Use better quality paintballs
A poor paintball to barrel bore match
Use a better paintball to barrel bore size match
The inline regulator is supercharging
Strip and clean inline regulator
Dirty body filter
Strip and clean the body filter
Poor / inconsistent air supply into POPS
Use a good quality pre-set air system
The GEO3.5 is inefficient
The Dwell is excessively high
Reduce the Dwell
The GEO3.5 has low rate of fire
The Solenoid Flow Restrictor is set too low
Increase the amount of flow on the SFR
The force setting on the loader is too low
Adjust the loader force feed setting