The magnet return strength screw is used to adjust the amount of force with
which the trigger is returned to its rest position by the magnet. Turn the screw
clockwise to increase the amount of force. Do not turn the screw too far or it will
negate the position of the front stop screw. Turn the screw counter-clockwise to
reduce the amount of force. Do not turn the screw too far or there may not be
enough force to return the trigger
(see figure 7D)
.
The micro-switch activation screw is used to adjust the point in the trigger pull
at which the micro-switch is activated (only if the Trigger parameter on page 37
is set to ‘SWITCH’). Turn the screw clockwise to decrease the amount of trigger
travel to the activation point. Turn the screw counter-clockwise to increase the
amount of trigger travel to the activation point
(see figure 7E)
. Do not set the
micro-switch activation screw too far out when using the OPTO sensors, as the
screw can stop against the micro-switch before the trigger prong enters the
OPTO sensors.
The spring return strength screw is used to adjust the spring strength that returns
the trigger to its resting position. Turn the screw clockwise to increase the amount
of spring return strength in the trigger pull. Turn this screw counter-clockwise to
reduce the amount of spring return strength in the trigger pull. Do not turn the
screw too far counter-clockwise or there will not be enough force to return the
trigger consistently
(see figure 7F)
.
When setting the trigger it is important to ensure that the electronic trigger
detection is working correctly. When the trigger is fully depressed the Trigger
Detection Indicator (TDI) should point upwards
. When the trigger is fully
released the TDI should point downwards
.
For more information, see understanding the Trigger Detection Indicator (TDI) on
page 24 and the Filter menu on pages 34-36.
FIG 7D
FIG 7E
FIG 7F
WARNING!
The trigger has been factory set to provide the necessary return force and
travel to minimize the risk of accidental discharge.
DO NOT make any adjustment to the trigger return strength, trigger actuation
point, trigger actuation pre-travel or trigger post actuation travel that could
result in an increased risk of accidental discharge.
This includes, but is not limited to, reducing the magnetic return force,
reducing the spring return force, reducing the trigger pre-travel to actuation
point or reducing the trigger post-travel after the actuation point.
The magnet return strength screw (see Fig7A - E) must NOT be adjusted so
that any part of the screw is visible beyond the inner surface of the trigger (see
Fig7D). The magnet return strength screw must NEVER be removed from the
trigger. Incorrect adjustment of the magnet return strength screw could result
in serious injury or death.
Prior to each use and before switching on the marker, visually inspect the
trigger to verify that all adjustment screws are in place and that no adjustments
have been made that may result in accidental discharge. If in doubt, seek
professional advice before switching on the marker.