Disclaimer Notice

In accordance with the manufacturer’s policy of continual
product improvement, the product presented in this
brochure is subject to change without notice or obligation.

The material in this manual is believed adequate for the
intended use of the product. If the product is used for
purposes other than those specified herein, confirmation
of validity and suitability must be obtained. Eclipse
warrants that the product itself does not infringe upon any
United States patents. No further warranty is expressed or
implied.

Liability & Warranty

We have made every effort to make this manual as
accurate and complete as possible. Should you find errors
or omissions, please bring them to our attention so that we
may correct them. In this way we hope to improve our
product documentation for the benefit of our customers.
Please send your corrections and comments to our
Technical Documentation Specialist.

It must be understood that Eclipse’s liability for its product,
whether due to breach of warranty, negligence, strict
liability, or otherwise is limited to the furnishing of
replacement parts and Eclipse will not be liable for any
other injury, loss, damage or expenses, whether direct or
consequential, including but not limited to loss of use,

income, or damage to material arising in connection with
the sale, installation, use of, inability to use, or the repair
or replacement of Eclipse’s products. 

Any operation expressly prohibited in this manual, any

adjustment, or assembly procedures not recommended or 
authorized in these instructions shall void the warranty. 

Document Conventions

There are several special symbols in this document. You
must know their meaning and importance.

The explanation of these symbols follows below. Please
read it thoroughly.

How To Get Help

If you need help, contact your local Eclipse
representative. You can also contact Eclipse at:

1665 Elmwood Rd.
Rockford, Illinois 61103 U.S.A.
Phone: 815-877-3031
Fax: 815-877-3336
http://www.eclipsenet.com

Please have the information on the product label available
when contacting the factory so we may better serve you.

Product Name
Item #
S/N
DD MMM YYYY

www.eclipsenet.com

This is the safety alert symbol. It is used to alert you to potential personal
injurt hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.

Indicates a hazardous situation which, if not avoided, will result in death
or serious injury.

Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.

Is used to address practices not related to personal injury.

Indicates an important part of text. Read thoroughly.

NOTE

NOTICE

CAUTION

WARNING

Содержание BrightFire 200 series

Страница 1: ...Eclipse BrightFire 200 Burners BRT Size G M and B Version 1 Operating Instructions Edition 09 15...

Страница 2: ...and Eclipse will not be liable for any other injury loss damage or expenses whether direct or consequential including but not limited to loss of use income or damage to material arising in connection...

Страница 3: ...l of Components 6 BrightFire 200 Adjustable Burners 7 Gimbal Mounting Bracket Installation 7 Pre Start Considerations 7 BrightFire 200 Installation and Start Up During Initial Heat Up Furnace 8 Bright...

Страница 4: ...ncreased flame control and burner flexibility Lower NOX emissions Compatible with current mounting bracket for easy installation Compatible with current BrightFire gas and cool ing air connections for...

Страница 5: ...er equipment installed under the furnace port Eclipse recommends installing a safety guard around moving parts Eclipse recommends considering any area with moving mechanical parts a restricted area Th...

Страница 6: ...ks from UL FM CSA European EN 746 2 with CE mark from TuV Gastec Advantica Electrical Wiring All the electrical wiring must comply with all applicable local codes and or standards such as NFPA Standar...

Страница 7: ...termined from the furnace and port information Gimbal Mounting Bracket Installation NOTE For additional info on the Gimbal Mounting Bracket refer to Info Guide 1113 1 Set all bracket adjustments to ze...

Страница 8: ...main burners is increased the heat up burner input is decreased to maintain the heat up schedule until the heat up burner can be removed Figure 3 1 Typical Installation Under port Figure 3 2 Typical...

Страница 9: ...ngement incorporates two burners per port Both burners of any given port should have equal gas flow and be adjusted in pairs when balancing gas flow On a typical under port fired furnace either side p...

Страница 10: ...et the main gas flow control to manual and open to 10 15 7 Establish gas and cooling air supply up to the local shut off valves 8 Beginning with one burner on the off firing side of the furnace discon...

Страница 11: ...tation of the adjustment knob will lengthen the flame while moving the adjustment forward clockwise rotation of the adjustment knob will shorten the flame To read the indicator rod positions for the a...

Страница 12: ...ed further from the port opening while maintaining lower NOX emissions Converting BrightFire 200 from Gas to Oil Firing NOTE If firing heavy fuel oil the oil must be conditioned to maintain a viscosit...

Страница 13: ...ate plugging of the regenerator ports instrumentation issues or furnace wear allowing infiltration of ambient air A side to side bias in the ratios may be required 5 Check the rear packing nuts to ver...

Страница 14: ...and nut but do not tighten 20 Insert the inner gas tube through the rear of the burner until the end is flush with the area adjustment lug 21 Tighten the inner gas tube locking nut and the packing gla...

Страница 15: ...illimeter mm inch in 3 94 x 10 2 MJ Nm Btu ft standard 26 86 From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1 millimeter mm meter m 0 0...

Страница 16: ...Eclipse Inc All Rights Reserved...