Troubleshooting
6-36
Algas-SDI Operations & Maintenance Manual P/N 52632
FULL LOAD CURRENT CHECK
Measure the current on each of the three heater power wires when the
contactors are closed.
See the Data Sheet or Nameplate
on the vaporizer for
the correct reading (line current) for your vaporizer. All three wires should have
equal re/- 3%.
If current readings are uniformly low, you have a low voltage. If current readings
are very different from each other, you may have a defective heater, defective
wiring or open fuse links.
See Heater Resistance Check.
Figure 13 - Full Load Current Check
Full Load Current Check.dxf
AC AMP