5)  Beginning  with  a  low  power  level,  the  operator  will  notice  the  effect  on  the  skin  and 

increase the power level to obtain the desired effect. 

6)  There are RANGE and RATE suggested values, however, the operator has the final word 

on  personalized  protocols  according  to  their  experience  and  the  clinical  evaluation 
obtained on specific treatments 

2.4 CONTRAINDICATIONS 

The  equipment  must  be  used  only  under  the  conditions  recommended  for  its  proper  use  and 
proven  efficiency.  Do  not  use  unless  under  direct  supervision  of  expert  personal  specifically 
trained in its use. 

Proceed  with  caution  during  treatments  until  the  operator  knows  perfectly  the  biological 
interaction mechanism between cavitational energy and the skin. 

3.  DESCRIPTION 

3.1 INTRODUCTION 

The  physical  phenomenon  of cavitation  used  by  CAVIX  has  been  used more  and more  the  last 
few  years  in  esthetics  to  treat fatty  layers  and  cellulite,  because  of  its  speed  and  effectiveness. 
This is easily understood if we consider that cavitation acts  upon liquids and that the superficial 
layer of fat is characterized by being mainly composed of liquids.  

For this reason, for body reshaping today it is the only valid and effective alternative to a surgical 
treatment of the localized fatty layers. Furthermore, thanks to the synchronization system, CAVIX 
ensures a calibrated frequency of ultrasound emission guaranteeing a safe treatment, respecting 
the  integrity  of  the  other  tissues  of  the  body.  In  other  words,  the  control  the  micro  processor 
carries  out  on  the  ultrasonic  frequency  causes  the  waves  to  produce  its  effect  only  on  the  fatty 
tissue.  

The CAVIX ultrasonic emission is characterized for having the possibility of variable frequency in 
the  production  of  ultrasound.  The  operator  can  freely  select  RANGE  as  well  as  RATE.  RANGE 
being the interval in which the frequency varies and RATE is the output speed.  

In the following pages you will find useful information that will allow you to use the equipment in 
the  most  appropriate  form.  We  suggest  reading  these  instructions  carefully  before  using  the 
CAVIX equipment and to save them for future use. 

Remember that this product must be used exclusively for its intended use. 

The equipment must be used solely under the continued control of qualified personal. 

The equipment must only be used in authorized centers that comply with current regulation. 

The  equipment  must  only  be  used  for  esthetic  treatments  of  localized  fatty  tissue  and  small 
esthetic defects caused by cellulite. 

The equipment is only indicated for: RESHAPING FATTY AREAS AND CELLULITE. 

The equipment must only be used on healthy individuals that are in good physical conditions. 

Содержание CAVIX

Страница 1: ...can it be reproduced multiplied or published through any electronic data processing form The information contained in this manual may be modified or broaden without previous notification without it r...

Страница 2: ...ALLATION AND SET UP 9 4 1 UNPACKING 9 4 2 POSITIONING 9 4 3 REVISION 9 5 OPERATION 9 6 TREATMENTS 11 6 1 BEFORE STARTING THE TREATMENT 11 6 2 GENERAL PRECAUTIONS 11 6 3 CONTRAINDICATIONS 11 6 4 COMPLI...

Страница 3: ...RIS will not assume any liability for damages that may occur if the device is used without following the instructions and or ignoring the following advice Keep the device out of children reach Do not...

Страница 4: ...permanent review If the system is sold or donated the user manual must be deliver with the device If by any of the following Inadequate use of the equipment Failure to use the instruction manual Bad m...

Страница 5: ...ng liquid on the equipment The manufacture will not be held responsible for any use of the equipment different from that which it is intended The use of commands controls or procedure sequences that a...

Страница 6: ...e to a surgical treatment of the localized fatty layers Furthermore thanks to the synchronization system CAVIX ensures a calibrated frequency of ultrasound emission guaranteeing a safe treatment respe...

Страница 7: ...t upon the fatty tissue 3 3 INTENDED USER The equipment is intended to be used by dermatologists or beauticians with specific training in the technique of cavitation 3 4 COMPONENTS The CAVIX includes...

Страница 8: ...INMANUUIN185 Rev 2019 04 01 ENG 3 Applicator connector 4 Pedal connector 5 Power cable conenector with fuse holder 6 Power switch 7 Air vent CAVITATION APPLICATOR CAVITATION APPLICATOR SUPPORT FOOTSW...

Страница 9: ...n or if it is on turn it off immediately and consult one of our authorized assistance centers 4 3 REVISION Once the installation is complete and before turning on the CAVIX we recommend carrying out t...

Страница 10: ...the RANGE value respectively the indicator 2 will show the programmed value This value indicates the range of frequencies emitted only when the SWEEP mode is ON The range of emitted ultrasound freque...

Страница 11: ...xclusively by operators properly trained in the use of cavitation equipment and only after reading this manual completely The information provided in this section does not aim at covering all the prob...

Страница 12: ...ld communicate the sensations experimented and the variations of these sensations To be explicit this is not a treatment with definite results because that would depend on eating habits and possible c...

Страница 13: ...ns Periodic cleaning of all external components Clean applicators Check connections Annual technical verification of the equipment For any type of maintenance work or revision contact your local distr...

Страница 14: ...aving a spare fuse on hand 1 Disconnect the power cable from the electric current and from the device 2 Under the connector for the power cable there is a small rectangular plastic piece where the fus...

Страница 15: ...ing The output selected is incorrect or the intensity is too low Select the correct output pressing the button 8 on the front panel Check the programmed intensity Defective applicator Check the estate...

Страница 16: ...CAVIX has passed our Quality Control and no defects have been found in its manufacture therefore guarantees proper working order under adequate conditions that are indicated in this manual The guaran...