Ecleris CAVIX Скачать руководство пользователя страница 3

USER MANUAL

– CAVIX 

 

Page 

3

 of 

16

 

INMANUUIN185 Rev.2019.04.01 / ENG 

1.  SYMBOLS 

 

Read the related documentation 

 

 

Pressure limits

 

 

 

Warning! 

 

 

Humidity limits 

 

Alternate current 

 

Manufacturers  information 
(Name, Address) 

 

Protect from water 

I

 

ON 

 

This side up 

 

OFF 

 

Temperature limits 

 

Fragile 

 

Do not discard with the household 
waste 

 

 

 

 

 

 

2.  SAFETY INFORMATION 

This manual contains all the information pertaining to proper care and use of the equipment and 
accessories. 

Please, read carefully through the entire manual before using the equipment. 

This  symbol  is  used  in  the  manual  to  indicate  important  information  with  warnings  or 
cautions. 

If  you  have  any  questions  on  the  content  of  this  manual,  the  operation  or  security  of  the 
equipment, please contact the local distributor or your nearest ECLERIS office. 

2.1 GENERAL WARNINGS 

It is important to read this manual carefully before using the CAVIX.  

ECLERIS  will not assume any liability for  damages that may occur if the device is used  without 
following the instructions and/or ignoring the following advice: 

  Keep the device out of children reach.  

  Do not install the device close to heat sources like stoves.  

  Always install the device on top of firm and horizontal surfaces, on a perfect ventilated 

area. 

  Do not block the ventilation screens. This ventilation must assure good air flow. 

  Avoid device exposure to direct sun light, dust, humidity, vibration or shock. 

  Do not put any container with liquids on top of the device, do not expose the device to 

rain or sun. 

  Do  not  use  volatile  substances  (benzene,  thinner,  solvents  in  general)  to  clean  the 

equipment, these  can  damage  it. We  recommend  using  a  soft  damp  cloth  with  neutral 
soap or products used to clean cabinets of electronic products. 

  Do not introduce objects into the holes and do not rest containers holding liquid on the 

equipment. 

  Avoid stepping on the power cable o pressing it under furniture. 

  Do not bend or tied a nut on the power cable, or any cable connected to the device. 

Содержание CAVIX

Страница 1: ...can it be reproduced multiplied or published through any electronic data processing form The information contained in this manual may be modified or broaden without previous notification without it r...

Страница 2: ...ALLATION AND SET UP 9 4 1 UNPACKING 9 4 2 POSITIONING 9 4 3 REVISION 9 5 OPERATION 9 6 TREATMENTS 11 6 1 BEFORE STARTING THE TREATMENT 11 6 2 GENERAL PRECAUTIONS 11 6 3 CONTRAINDICATIONS 11 6 4 COMPLI...

Страница 3: ...RIS will not assume any liability for damages that may occur if the device is used without following the instructions and or ignoring the following advice Keep the device out of children reach Do not...

Страница 4: ...permanent review If the system is sold or donated the user manual must be deliver with the device If by any of the following Inadequate use of the equipment Failure to use the instruction manual Bad m...

Страница 5: ...ng liquid on the equipment The manufacture will not be held responsible for any use of the equipment different from that which it is intended The use of commands controls or procedure sequences that a...

Страница 6: ...e to a surgical treatment of the localized fatty layers Furthermore thanks to the synchronization system CAVIX ensures a calibrated frequency of ultrasound emission guaranteeing a safe treatment respe...

Страница 7: ...t upon the fatty tissue 3 3 INTENDED USER The equipment is intended to be used by dermatologists or beauticians with specific training in the technique of cavitation 3 4 COMPONENTS The CAVIX includes...

Страница 8: ...INMANUUIN185 Rev 2019 04 01 ENG 3 Applicator connector 4 Pedal connector 5 Power cable conenector with fuse holder 6 Power switch 7 Air vent CAVITATION APPLICATOR CAVITATION APPLICATOR SUPPORT FOOTSW...

Страница 9: ...n or if it is on turn it off immediately and consult one of our authorized assistance centers 4 3 REVISION Once the installation is complete and before turning on the CAVIX we recommend carrying out t...

Страница 10: ...the RANGE value respectively the indicator 2 will show the programmed value This value indicates the range of frequencies emitted only when the SWEEP mode is ON The range of emitted ultrasound freque...

Страница 11: ...xclusively by operators properly trained in the use of cavitation equipment and only after reading this manual completely The information provided in this section does not aim at covering all the prob...

Страница 12: ...ld communicate the sensations experimented and the variations of these sensations To be explicit this is not a treatment with definite results because that would depend on eating habits and possible c...

Страница 13: ...ns Periodic cleaning of all external components Clean applicators Check connections Annual technical verification of the equipment For any type of maintenance work or revision contact your local distr...

Страница 14: ...aving a spare fuse on hand 1 Disconnect the power cable from the electric current and from the device 2 Under the connector for the power cable there is a small rectangular plastic piece where the fus...

Страница 15: ...ing The output selected is incorrect or the intensity is too low Select the correct output pressing the button 8 on the front panel Check the programmed intensity Defective applicator Check the estate...

Страница 16: ...CAVIX has passed our Quality Control and no defects have been found in its manufacture therefore guarantees proper working order under adequate conditions that are indicated in this manual The guaran...