NPT-1020 Installation and Maintenance Manual
Before You Start
ECI Telecom Ltd. Proprietary
3-17
Module
Parameter
Data
Source type
Single mode Single
mode
Single
mode
Single
mode
Single
mode
Minimum mean launched
power (dBm)
-15
-5
-5
-14
-14
Maximum mean launched
power (dBm)
-8
0
0
-8
-8
Table
3-13: LC transceivers laser information GbE SFP (OTGBE)
Module
Parameter
Data
GbE SFP
Laser designation
SX
LX
EX
Operating
wavelength (nm)
850
1310
1550
Source type
Multi-mode
Single mode
Single mode
Minimum mean launched power
(dBm)
-9.5
-11
0
Maximum mean launched power
(dBm)
-3
-3
5
3.7
Protection against Electrostatic Discharge
This section provides guidelines regarding the protection of NPT-1020 equipment and its components
against electrostatic discharge (ESD) during handling, packing/unpacking, transport, installation,
commissioning, inspections, servicing, and maintenance.
Electronic equipment, assemblies, and components that are ESDS (electrostatic discharge sensitive) or
include sensitive items are identified by the basic ESD warning symbol shown in the following figure.
Figure
3-3: Basic ESD warning symbol
The information provided in this section is in line with CENELEC Electronic Components Committee (CECC)
specification CECC 00 015, which deals with protection of devices sensitive to ESD.
Most types of electronic equipment, assemblies, and components can be damaged by electrostatic
discharges. An ESD between two objects occurs when an object carrying static electrical charges touches or
is brought near another object.