background image

6

Installation

The controller is mounted directly to an electrical junction box or panel at the electrical 

lighting load or before the load in the circuit.

Note: If the circuit will have an additional hard wired switch, wire the dimmer in series 

before the switch.

Important Safety Instructions

WARNING

Risk of electric shock! This dimmer utilizes high voltage 

and should only be installed by a qualified installer or 

electrician. Follow all local codes for installation. Before 

terminating the AC power wiring verify the main breaker 

is in the off position and follow the proper lockout/tag out procedures 

per NFPA Standard 70E.

For indoor use only! 

Must install to an electrical junction box or wire way.

1.  Locate the circuit breaker panel and turn off the power to the lighting circuit.

2. Remove the face plates and other hardware from the junction box, gaining access 

to the high voltage wiring.

3. The dimmer mounts to the exterior of the junction box or panel with the 1/2” 

(13mm) threaded nipple.

Note: Follow all local code requirements for terminating wire.

The dimmer is supplied with a wire harness that is specific to the input voltage, either 

120VAC or 277VAC.

a.  Connect the green/yellow striped wire to the ground wire from the breaker 

panel and the ground wire from the lighting load.

b. Connect the white wire to the incoming neutral wire from the breaker panel and 

the neutral wire of the lighting load.

c.  Connect the incoming hot wire (black for 120VAC or brown wire for 277VAC) to 

the line input feed wire (hot) from the breaker panel.

d.  Connect the red output wire to the lighting load.

Wiring Diagram

Load

White

Neutral

Red

ER6CD

Orange - Antenna

Dimmer

Green/
Yellow

Black 120V

Brown 277V

or

Содержание ER6CD

Страница 1: ...trols 120V electronic low voltage transformer loads Neither of these controllers can accommodate magnetic or step down transformer loads These controllers have a single channel dimming output and uses...

Страница 2: ...essed while the lights are on and the timer is counting down an additional period of time is added to the timer total Example if the timer setting is 1 hour and the user presses the switch ON twice th...

Страница 3: ...t specification item details that a certain value of light must be measured on a desktop The dimming light fixture providing light to the desktop is controlled The light sensor is located over the des...

Страница 4: ...ange confirmation feature to provide visual feedback of a linked sensors signal strength for optimal sensor placement To evaluate the radio signal strength the sensor must be also support the test and...

Страница 5: ...isrupt transmissions Fire doors elevator shafts stairwells storage areas and any large metal objects can create radio shadows and disrupt wireless transmissions It is recommended that switches and sen...

Страница 6: ...off the power to the lighting circuit 2 Remove the face plates and other hardware from the junction box gaining access to the high voltage wiring 3 The dimmer mounts to the exterior of the junction b...

Страница 7: ...ton marked LEARN for a half second In link mode the LEARN LED will stay ON and the POWER LED will toggle every 2 second 2 Using the switch that will be linked to the controller press the wall switch O...

Страница 8: ...mming mode the Status LED will flash amber and the CLR LRN LED will indicate the current mode with specific LED colors red is Reverse Phase dimming mode and green is Forward Phase dimming mode 2 To ch...

Страница 9: ...taps 10 min 3 blinks 6 taps 15 min 4 blinks 7 taps 20 min 5 blinks 8 taps 25 min 6 blinks for demonstration purposes only 2 After the controller has completed responding to the change press the sensor...

Страница 10: ...ge 2 Open Loop The lighting set point can be set to an absolute value useful in open loop sensor applications The absolute value selected becomes the maximum dimming set point 1 With the light on tap...

Страница 11: ...he light is dimming down up twice Press ON for three seconds 2 Click the switch ON 5 times to clear the switch click ON 5 times again to clear ALL switches and sensors and reset the controller to defa...

Страница 12: ...crease the timeout in 5 minute increments 4 To continue with configuration press ON for 3 seconds the light will resume dimming down up five times To exit Smart Click press OFF for 5 seconds Light Tim...

Страница 13: ...es past day lighting set point The lights will turn ON upon the next motion detected by the occupancy sensor When set for daylight harvesting operation the set point is used with a photo sensor light...

Страница 14: ...wn up nine times 2 Press ON for 3 seconds Default setting is 100 Adjust the maximum light level to the brightness level desired by clicking ON to increase and OFF to decrease in 2 increments 3 To cont...

Страница 15: ...Minimum Dimming Output enabled Motion sensor Time out 15 minutes Switch Time out no time out Auto ON Time out enabled with no linked switch disabled with linked rocker switch Light ON Set point 60 of...

Страница 16: ...rmful interference and ii this device must accept any interference received including interference that may cause undesired operation IC RSS 210 Contains IC 5713A STM300U echoflex Powered by ETC Echof...

Отзывы: