background image

Echoflex Installation Guide

Dual Tech Vacancy Sensor

Prepare for Installation

Elaho Dual Tech Wall-mount Vacancy Sensors ship with electronics, a
decorator style wall plate, and a termination kit. The sensor may be installed
into an industry standard back box (provided by others) or surface mounted
back box (sold separately and available from Echoflex).

Note:

Installation must follow all national and local codes for electrical

equipment.

Compliance

UL/cUL listed, complies with UL508A, UL916, and CSA C22.2 No. 14

CE compliant

For use with Echoflex dimming and relay products.

Environment

Ambient

For indoor, commercial controls use only. The sensor operates in ambient
temperatures of -10°C to 40°C, with a maximum of 90% non-condensing
humidity.

Installation

Echoflex recommends paying special attention to the installation
environment:

When operating in PIR only modes, the sensor must have an
unobstructed view of the room. Do not mount behind or near tall
cabinets, shelves, hanging light fixtures, etc.

Do not install the sensor within eight feet from an HVAC airflow
duct/vent.

Install the sensor where it cannot easily sense movement in areas
outside of the intended space, such as hallways, glass partitions, or
adjacent rooms.

Note:

In areas of increased noise activity, enabling PIR only mode may

allow for better occupancy detection results. See

DIP Switch Settings on

page 7

.

Dual Tech Wall-mount Vacancy Sensor

Page 2 of 12

Echoflex Solutions, Inc.

Содержание Elaho Dual Tech Wall-mount Vacancy Sensor

Страница 1: ...y upon detection of vacancy The wall mount unit offers up to 140 degree field of detection with optimized lens options to accommodate wide or narrow angle spaces and is available in white black or cre...

Страница 2: ...ls use only The sensor operates in ambient temperatures of 10 C to 40 C with a maximum of 90 non condensing humidity Installation Echoflex recommends paying special attention to the installation envir...

Страница 3: ...or ESD protection Pull an additional 14 AWG 2 5 mm2 wire for grounding when control wires are not installed in grounded metal conduit Note When using Category 5 or equivalent cable on the EchoConnect...

Страница 4: ...0 mm 2 Connect the EchoConnect pigtail wires from the mounting bracket to the installed wall wires a Connect the data typically black EchoConnect wire from mounting bracket to the incoming EchoConnect...

Страница 5: ...ets engage d If the wall plate does not fully attach wiggle the bottom of the plate until all of the magnets are seated properly a b c d 5 Attach the sensor head a Slide the removable cover off the se...

Страница 6: ...used and have no functionality on the Dual Tech Wall mount Vacancy Sensor Set Space and Address Two rotary switches on the controller provide for assignment of the sensor Space and Address By default...

Страница 7: ...red Instead the settings made by the EchoAccess Mobile App are used 3 and 4 Vacancy Timeout 5 min Switches 3 and 4 are Off 15 min Switch 3 is Off and Switch 4 is On default 30 min Switch 3 is On and S...

Страница 8: ...hen the vacancy timeout in the space has only been reset by acoustic detection for 60 minutes acoustic detection is disabled until the next PIR detection event PIR only Detection When acoustic detecti...

Страница 9: ...he sensor does not detect occupancy again during the vacancy timeout period the lights turn off and a 30 second grace period begins Grace Period The sensor features a 30 second grace period after a va...

Страница 10: ...f the sensor to enable the Walk Test feature A green LED will flash indicating Walk Test is enabled and the vacancy timer will be shortened to ten seconds 3 Move throughout the space including corners...

Страница 11: ...or Sensor Coverage Narrow Lens 100ft 30 5m 18 3m 60ft 2 2m 7ft 1m 3ft 2 1m 6 8ft 3m 10ft 10 7m 35ft 6 56 2 5m 8ft 0 C L 77 29 21 5 14 5m 16ft 5m 16ft 2 5m 8ft Top View Side View Dual Tech Wall mount V...

Страница 12: ...e Dual Tech Vacancy Sensor Wide Lens 19 4 0 5m 10m 16ft 33ft 5m 10m 16ft 33ft 15 3m 7 7 m 4 6m 1 7m 50ft 25ft 15ft 6ft 2 1m 6 8ft 140 Top View Side View Dual Tech Wall mount Vacancy Sensor Page 12 of...