E
ARTH
A
UGER
O
PERATOR
'
S
M
ANUAL
13
STOPPING
ENGINE
1.
Release Throttle.
Allow engine to return to idle before shutting off engine.
2.
Stop Switch
Move stop switch button (B) backward to "STOP" position.
WARNING
DANGER
If engine does not stop when stop switch is moved to STOP
position, close choke - COLD START position - to stall engine.
Have your ECHO dealer repair stop switch before using unit again.
STARTING
WARM
ENGINE
The starting procedure is the same as Cold Start, except DO NOT close
the choke.
WARNING
DANGER
When engine starts, the auger attachment may rotate, even with the
throttle trigger in idle (released) position.
1.
Stop Switch
Move stop switch button (B) forward, away from the "STOP"
position.
2.
Primer
Pump primer bulb (E) until fuel is visible in the "Clear" fuel return
line. Pump bulb an additional 4 or 5 times.
3.
Decompression Button
Press decompression button (D) once.
4.
Recoil Starter.
Lay the unit on a flat, clear area, and pull the recoil starter handle
(A) until the engine fires.
NOTE
If engine does not start after 5 pulls, use Cold Start Procedure.
E
B
A
D
B