background image

HIGH PRESSURE PUMP SYSTEM  

TROUBLESHOOTING GUIDE 

 
 

MALFUNCTION 

 

CAUSE 

 

 

 

REMEDY

    

 

The pressure 

 

 

Worn packing seals 

 

 

Replace seals  

drops   

 

 

broken valve spring 

 

 

Replace spring 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fouled inlet strainer  

 

 

Clean strainer 

 

 

 

 

Fouled pre-filter(s) 

 

 

Replace filter cartridge(s) 

Cavitation  

              

 

Check suction lines for  

 

 

 

 

 

restrictions 

 

 
Water in crankcase 

 

High humidity   

 

 

Reduce oil change interval 

 

 

 

 

Worn seals 

 

 

 

Replace seals 

 
 
Noisy operating  

 

Worn bearings    

 

 

Replace bearings, refill crankcase 

 

 

 

 

 

 

 

 

with recommended lubricant 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cavitation 

 

 

 

Check inlet lines for restrictions 

 

 

 

 

 

 

 

 

 

Check strainer and filter(s) 

 
 
Inability to 

 

 

Discharge valve chamber 

 

Allow more time to prime  

build up pressure 

 

has air trapped within it  

 

and ensure that there are no  

 

 

 

 

 

 

 

 

 

air suction leaks. 

 

 

 

 

 

 

 

 

 

Open valve chambers and allow  

 

 

 

 

 

 

 

 

 

air to escape 

 
 
Rough/Pulsating 

 

Worn seals 

 

 

 

Replace seals 

operation with   

 

 

 

 

 

 

Check system for stoppage or  

 

 

 

 

 

 

 

 

air suction leaks 

pressure drop   

 

Cavitation 

 

 

 

Check inlet lines for restrictions 

 

 

 

 

 
 
Excessive  

 

 

Worn plunger(s) 

 

 

Replace plunger(s)  

leakage between 

 

Worn seals 

 

 

 

Replace seals 

the high pressure 

 

 

 

pump manifold   

 

Cracked plunger(s) 

 

 

Replace plunger(s) 

and rear crankcase 

 

 

 

section  
 
 
High crankcase   

 

Wrong grade of oil  

 

 

Use specified type of oil. 

temperature 

 

 

Improper amount of oil in crankcase 

Adjust oil level to proper  

 

 

 

 

 

 

 

 

 

amount 

Содержание 900-BHL- 2

Страница 1: ...5 STANDARD SYSTEM FEATURES INSTALLATION LAYOUT 6 7 INSTALLATION INSTRUCTIONS 8 9 OPERATION INSTRUCTIONS 10 MEMBRANE CLEANING PROCEDURE 11 MAINTENANCE TIMETABLE 12 TROUBLESHOOTING GUIDE 13 14 HIGH PRES...

Страница 2: ...familiar with each component of your new ECHO Tec desalination system By understanding the function importance and normal operation of each part in the system the operator can readily diagnose proble...

Страница 3: ...NE TYPE Specifically selected high rejection proprietary TFC Polyamid thin film composite spiral wound single pass reverse osmosis element SALT REJECTION min 99 5 SALINITY RANGE up to 50 000 ppm TDS N...

Страница 4: ...s 1200 BHL 3 three 40 vessels 1500 BHL 4 four 40 vessels 6 20 feet 6 meter 1 2 reinforced vinyl hose reject product flush 10 feet 3 meter blue product water tubing membrane to flow panel 10 feet 3 met...

Страница 5: ...WATER LEVEL AT LOW TIDE Beach House Series Installation Layout Product Max 2 7m 9ft Max 9m 30ft Reject Non return valve Sea strainer...

Страница 6: ...reservative under best conditions is one year We recommend you install and use your watermaker as soon as possible When all other components and hoses pipes are completely assembled remove the caps on...

Страница 7: ...flow control box to the O ring sealed fitting at the end of the membrane that is market OUT CAUTION WHEN CONNECTING THE HIGH PRESSURE HOSE FITTINGS TO THE MEMBRANE HOUSING S AVOID TURNING THE MEMBRAN...

Страница 8: ...o the Service position to run the sea water supply pump only 5 Purge the seawater intake system until all entrapped air has escaped then switch the selector switch Off and bring the selector switch in...

Страница 9: ...end to store your watermaker for more than ten days growth of microorganism will degrade the RO membranes performance The RO membranes should be flushed with a biocide solution to preserve the membran...

Страница 10: ...on label CAUTION Do not mix different cleaning chemicals together Do not use different cleaning chemicals together at the same time Mix the cleaning chemicals separately and use them separately Note...

Страница 11: ...n intake 1000 hrs or when clogged Pre filters Replace or clean elements and clean housings When system intake pressure drops below 5psi Charcoal flush filter Replace element Every 6 months High pressu...

Страница 12: ...ns Check strainer and filter s Inability to Discharge valve chamber Allow more time to prime build up pressure has air trapped within it and ensure that there are no air suction leaks Open valve chamb...

Страница 13: ...wn on page 8 Inspection inlet outlet valves 2 1 Remove valve caps slide out inlet outlet valves check the sondition of the various components of the valve and well as the O Ring replace if necessary 2...

Страница 14: ...lacing oil seals 6 1 Remove the head See remove the ceramic pistons discharge oil 6 2 Remove the oil seals and the O Rings checking the seats and the piston guides 6 3 Remove the rear cover gasket 6 4...

Страница 15: ...ned to Echo Marine s Service Center The purchaser must pay any transportation or labor expenses incurred in removing and returning the product to the service center The limited warranty does not exten...

Страница 16: ...ranteed against iron fouling rust chemical attack extreme temperatures over 113 F under 33 F drying out or extreme pressures over 1000 psig CAUTION Use of parts not supplied directly by Echo Marine ge...

Отзывы: