INSTALLATION INSTRUCTIONS  

 

 

HIGH PRESSURE PUMP

 

UNIT

 

 
Mount the high pressure pump unit in a cool and dry location, not higher than 30ft above low water level 
at a distance not further than 100ft / 30m. 

The  electrical  installation  should  only  be  done  by  a  professional  electrician.    Check  the  correct 
voltage before installing the system.   
 

The “MAIN” marked cable is to be connected to the power supply.  The smaller cable, marked “PUMP” 
is to be connected to the raw water feed pump.

 

 

MEMBRANE VESSEL RACK

  

 
Mount  the  high-pressure  membrane  vessels  with  the  provided  brackets  below  the  high  pressure  pump 
unit.  Vertical mounting is possible if space is limited but you will need to order different high pressure 
hose lengths.  
 

The  membrane  is  sealed  within  its  housing  by  plugs  at  both  ends.    Inside  is  a  small  amount  of 
preservative to keep the membrane moist and prevent bacterial growth.   
 
It  is  important  that  this  preservative  does  not  evaporate  and  allow  the  membrane  to  dry  out.    If 
this happens, the membrane will be destroyed.   

 

The  shelf  life  of  the  preservative,  under  best  conditions,  is  one  year.    We  recommend  you  install 
and use your watermaker as soon as possible.

   

 
When  all  other  components  and  hoses/pipes  are  completely  assembled,  remove  the  caps  on  the  high 
pressure fittings and the blue sealed tube from the product water outlet on the membrane housings, then 
finish making all final hose/tube connections.  This will insure that the membrane is kept moist until the 
last possible moment before operation. 

 

PRE-FILTER ASSEMBLY 

 

Mount the pre-filter in a serviceable location and connect the intake port to the outlet of the raw water 
feed  pump  or  multi-media  sand  filter  (optional).    For  short  runs,  use  5/8”  reinforced  PVC  hose.    For 
longer  runs,  use  a  5/8”  or  3/4”  PVC  pipe.    Connect  the  outlet  of  the  pre-filter  housing  with  a  3/4” 
reinforced PVC hose to the intake of the high pressure pump. 
 

INSTALL ALL PLUMBING TO ELIMINATE ANY AIR POCKETS IN THE SYSTEM  

 

FRESH WATER FLUSH FILTER 

 
Install the fresh water flush filter housing at a location near the seawater pre-filter assembly.  Connect the 
flush  port  of  the  three-way  service  valve  at  the  pre-filter  assembly  with  the  outlet  of  the  flush  filter 
housing (out).  Supply pressurized fresh water to the shut off valve of the flush filter housing. 

Содержание 900-BHL- 2

Страница 1: ...5 STANDARD SYSTEM FEATURES INSTALLATION LAYOUT 6 7 INSTALLATION INSTRUCTIONS 8 9 OPERATION INSTRUCTIONS 10 MEMBRANE CLEANING PROCEDURE 11 MAINTENANCE TIMETABLE 12 TROUBLESHOOTING GUIDE 13 14 HIGH PRES...

Страница 2: ...familiar with each component of your new ECHO Tec desalination system By understanding the function importance and normal operation of each part in the system the operator can readily diagnose proble...

Страница 3: ...NE TYPE Specifically selected high rejection proprietary TFC Polyamid thin film composite spiral wound single pass reverse osmosis element SALT REJECTION min 99 5 SALINITY RANGE up to 50 000 ppm TDS N...

Страница 4: ...s 1200 BHL 3 three 40 vessels 1500 BHL 4 four 40 vessels 6 20 feet 6 meter 1 2 reinforced vinyl hose reject product flush 10 feet 3 meter blue product water tubing membrane to flow panel 10 feet 3 met...

Страница 5: ...WATER LEVEL AT LOW TIDE Beach House Series Installation Layout Product Max 2 7m 9ft Max 9m 30ft Reject Non return valve Sea strainer...

Страница 6: ...reservative under best conditions is one year We recommend you install and use your watermaker as soon as possible When all other components and hoses pipes are completely assembled remove the caps on...

Страница 7: ...flow control box to the O ring sealed fitting at the end of the membrane that is market OUT CAUTION WHEN CONNECTING THE HIGH PRESSURE HOSE FITTINGS TO THE MEMBRANE HOUSING S AVOID TURNING THE MEMBRAN...

Страница 8: ...o the Service position to run the sea water supply pump only 5 Purge the seawater intake system until all entrapped air has escaped then switch the selector switch Off and bring the selector switch in...

Страница 9: ...end to store your watermaker for more than ten days growth of microorganism will degrade the RO membranes performance The RO membranes should be flushed with a biocide solution to preserve the membran...

Страница 10: ...on label CAUTION Do not mix different cleaning chemicals together Do not use different cleaning chemicals together at the same time Mix the cleaning chemicals separately and use them separately Note...

Страница 11: ...n intake 1000 hrs or when clogged Pre filters Replace or clean elements and clean housings When system intake pressure drops below 5psi Charcoal flush filter Replace element Every 6 months High pressu...

Страница 12: ...ns Check strainer and filter s Inability to Discharge valve chamber Allow more time to prime build up pressure has air trapped within it and ensure that there are no air suction leaks Open valve chamb...

Страница 13: ...wn on page 8 Inspection inlet outlet valves 2 1 Remove valve caps slide out inlet outlet valves check the sondition of the various components of the valve and well as the O Ring replace if necessary 2...

Страница 14: ...lacing oil seals 6 1 Remove the head See remove the ceramic pistons discharge oil 6 2 Remove the oil seals and the O Rings checking the seats and the piston guides 6 3 Remove the rear cover gasket 6 4...

Страница 15: ...ned to Echo Marine s Service Center The purchaser must pay any transportation or labor expenses incurred in removing and returning the product to the service center The limited warranty does not exten...

Страница 16: ...ranteed against iron fouling rust chemical attack extreme temperatures over 113 F under 33 F drying out or extreme pressures over 1000 psig CAUTION Use of parts not supplied directly by Echo Marine ge...

Отзывы: